Gemalto M2M HC25 User Manual

s
HC25 Siemens Cellular Engine
Version: 00.220 DocId: HC25_HO_v00.220
Hardware Interface Overview
HC25 Hardware Interface Overview
2
s
Document Name: Version:
Date: DocId: Status: Supported Products:
General Notes
HC25 Hardware Interface Overview
00.220 2007-03-20 HC25_HO_v00.220 Confidential / Preliminary HC25
Copyright
Transmittal, reproduction, dissemination and/or editing of this document as well as utilization of its con­tents and communication thereof to others without express authorization are prohibited. Offenders will be held liable for payment of damages. All rights created by patent grant or registration of a utility model or design patent are reserved.
Copyright © Siemens AG 2007
HC25_HO_v00.220 Page 2 of 39 2007-03-20 Confidential / Preliminary
HC25 Hardware Interface Overview

Contents

39
s
Contents
1 Introduction.................................................................................................................6
1.1 Related Documents ...........................................................................................6
1.2 Terms and Abbreviations...................................................................................6
1.3 Regulatory and Type Approval Information .......................................................9
1.3.1 Directives and Standards......................................................................9
1.4 SAR requirements specific to portable mobiles............................................... 11
1.4.1 SELV Requirements ...........................................................................11
1.5 Safety Precautions...........................................................................................12
2 Product Concept.......................................................................................................13
2.1 Key Features at a Glance................................................................................13
3 Application Interface.................................................................................................16
3.1 Operating Modes .............................................................................................16
4 Antenna Interface......................................................................................................17
4.1 Antenna Installation .........................................................................................17
4.2 Antenna Pad....................................................................................................18
4.3 Antenna Connector..........................................................................................19
5 Electrical, Reliability and Radio Characteristics....................................................23
5.1 Absolute Maximum Ratings.............................................................................23
5.2 Operating Temperatures..................................................................................24
5.3 Storage Conditions ..........................................................................................25
5.4 Reliability Characteristics.................................................................................26
6 Mechanics..................................................................................................................27
6.1 Mechanical Dimensions of HC25.....................................................................27
6.2 Mounting HC25 to the Application Platform.....................................................29
6.3 Board-to-Board Application Connector............................................................29
7 Reference Approval..................................................................................................31
7.1 Reference Equipment for Type Approval.........................................................31
7.2 Compliance with FCC Rules and Regulations.................................................32
8 Appendix....................................................................................................................33
8.1 List of Parts and Accessories...........................................................................33
8.2 Fasteners and Fixings for Electronic Equipment .............................................35
8.2.1 Fasteners from German Supplier ETTINGER GmbH.........................35
8.3 Mounting Advice Sheet....................................................................................38
HC25_HO_v00.220 Page 3 of 39 2007-03-20 Confidential / Preliminary
HC25 Hardware Interface Overview

Tables

4
s
Tables
Table 1: Directives ......................................................................................................... 9
Table 2: Standards of North American type approval.................................................... 9
Table 3: Standards of European type approval.............................................................. 9
Table 4: Requirements of quality ................................................................................. 10
Table 5: Overview of operating modes ........................................................................ 16
Table 6: Return loss in the active band........................................................................ 17
Table 7: Product specifications of U.FL-R-SMT connector.......................................... 19
Table 8: Material and finish of U.FL-R-SMT connector and recommended plugs....... 20
Table 9: Ordering information for Hirose U.FL Series.................................................. 22
Table 10: Absolute maximum ratings............................................................................. 23
Table 11: Board temperature......................................................................................... 24
Table 12: Sample operating conditions without forced air circulation
(according to IEC 60068-2)............................................................................ 24
Table 13: Sample operating conditions with forced air circulation (air speed 0.9m/s)... 24
Table 14: Storage conditions......................................................................................... 25
Table 15: Summary of reliability test conditions............................................................. 26
Table 16: Electrical and mechanical characteristics of the board-to-board connector... 29
Table 17: List of parts and accessories.......................................................................... 33
Table 18: Molex sales contacts (subject to change)...................................................... 34
Table 19: Hirose sales contacts (subject to change)..................................................... 34
HC25_HO_v00.220 Page 4 of 39 2007-03-20 Confidential / Preliminary
HC25 Hardware Interface Overview

Figures

5
s
Figures
Figure 1: Restricted area around antenna pad (side and bottom view)......................... 18
Figure 2: Mechanical dimensions of U.FL-R-SMT connector.........................................19
Figure 3: U.FL-R-SMT connector with U.FL-LP-040 plug..............................................20
Figure 4: U.FL-R-SMT connector with U.FL-LP-066 plug..............................................20
Figure 5: Specifications of U.FL-LP-(V)-040(01) plug....................................................21
Figure 6: HC25 – Top and bottom view..........................................................................27
Figure 7: Dimensions of HC25 (all dimensions in mm)..................................................28
Figure 8: Mechanical dimensions of the board-to-board connector...............................30
Figure 9: Reference equipment for Type Approval........................................................ 31
HC25_HO_v00.220 Page 5 of 39 2007-03-20 Confidential / Preliminary
HC25 Hardware Interface Overview

1 Introduction

12
s
1 Introduction
This document describes the hardware of the Siemens HC25 module that connects to the cel­lular device application and the air interface. It helps you quickly retrieve interface specifica­tions, electrical and mechanical details and information on the requirements to be considered for integrating further components.

1.1 Related Documents

[1] HC25 AT Command Set 00.220 [2] HC25 Release Notes 00.220

1.2 Terms and Abbreviations

Abbreviation Description
ANSI American National Standards Institute AMR Adaptive Multirate ARP Antenna Reference Point B2B Board-to-board connector BB Baseband BEP Bit Error Probability BTS Base Transceiver Station CB or CBM Cell Broadcast Message CE Conformité Européene (European Conformity) CS Coding Scheme CS Circuit Switched CSD Circuit Switched Data DAC Digital-to-Analog Converter dBm0 Digital level, 3.14dBm0 corresponds to full scale, see ITU G.711, A-law DCS Digital Cellular System DL Download DRX Discontinuous Reception DSB Development Support Board DSP Digital Signal Processor DTMF Dual Tone Multi Frequency DTX Discontinuous Transmission EDGE Enhanced Data rates for GSM Evolution EFR Enhanced Full Rate EGSM Enhanced GSM
HC25_HO_v00.220 Page 6 of 39 2007-03-20 Confidential / Preliminary
HC25 Hardware Interface Overview
1.2 Terms and Abbreviations
12
Abbreviation Description
EMC Electromagnetic Compatibility ERP Effective Radiated Power ESD Electrostatic Discharge ETS European Telecommunication Standard ETSI European Telecommunications Standards Institute FCC Federal Communications Commission (U.S.) FDD Frequency Division Duplex FDMA Frequency Division Multiple Access FR Full Rate GPRS General Packet Radio Service GSM Global Standard for Mobile Communications HiZ High Impedance
s
HSDPA High Speed Downlink Packed Access HR Half Rate I/O Input/Output IF Intermediate Frequency IMEI International Mobile Equipment Identity ISO International Standards Organization ITU International Telecommunications Union kbps kbits per second LED Light Emitting Diode Mbps Mbits per second MCS Modulation and Coding Scheme MO Mobile Originated MS Mobile Station, also referred to as TE MT Mobile Terminated NTC Negative Temperature Coefficient PBCCH Packet Switched Broadcast Contro l Channel PCB Printed Circuit Board PCL Power Control Level PCM Pulse Code Modulation PCS Personal Communication System, also referred to as GSM 1900 PS Packet Switched PDU Protocol Data Unit PSK Phase Shift Keying R&TTE Radio and Telecommunication Terminal Equipment
HC25_HO_v00.220 Page 7 of 39 2007-03-20 Confidential / Preliminary
HC25 Hardware Interface Overview
1.2 Terms and Abbreviations
12
Abbreviation Description
RACH Random Access Channel RF Radio Frequency RTC Real Time Clock Rx Receive Direction SAR Specific Absorption Rate SELV Safety Extra Low Voltage SIM Subscri ber Identification Module SLIC Subscriber Line Interface Circuit SMS Short Message Service SRAM Static Random Access Memory SRB Signalling Radio Bearer TA Terminal adapter (e.g. GSM engine)
s
TDMA Time Division Multiple Access TE Terminal Equipment TS Technical Specification Tx Transmit Direction UL Upload UMTS Universal Mobile Telecommunications System URC Unsolicited Res ult Code USB Universal Serial Bus UICC USIM Integrated Circuit Card USIM UMTS Subscriber Identification Module WCDMA Wideband Code Division Multiple Access
HC25_HO_v00.220 Page 8 of 39 2007-03-20 Confidential / Preliminary
HC25 Hardware Interface Overview

1.3 Regulatory and Type Approval Information

12
s
1.3 Regulatory and Type Approval Information

1.3.1 Directives and Standards

HC25 has been designed to comply with the directives and standards listed below.
Table 1: Directives
99/05/EC Directive of the European Parliament and of the council of 9 March 1999
on radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity (in short referred to as R&TTE Direc­tive 1999/5/EC). The product is labeled with the CE conformity mark
2002/95/EC Directive of the European Parliament and of the Council of
27 January 2003 on the restriction of the use of certain hazardous substances in electrical and electronic equip­ment (RoHS)
Table 2: Standards of North American type approval
CFR Title 47 Code of Federal Regulations, Part 22 and Part 24 (Telecommunications,
PCS); US Equipment Authorization FCC
UL 60 950 Product Safety Certification (Safety requirements)
NAPRD.03 V3.9.1 Overview of PCS Type certification review board Mobile Equipment Type
Certification and IMEI control PCS Type Certification Review board (PTCRB)
RSS132, RSS133 Canadian Standard
Table 3: Standards of European type approval
3GPP TS 51.010-1 Digital cellular telecommunications system (Release 5); Mobile Station
(MS) conformance specification
ETSI EN 301 511 V9.0.2 Candidate Harmonized European Standard (Telecommunications series)
Global System for Mobile communications (GSM); Harmonized standard for mobile stations in the GSM 900 and DCS 1800 bands covering essen­tial requirements under article 3.2 of the R&TTE directive (1999/5/EC)
(GSM 13.11 version 7.0.1 Release 1998) GCF-CC V3.23.1 Global Certification Forum - Certification Criteria ETSI EN 301 489-1
V1.4.1
Candidate Harmonized European Standard (Telecom munications serie s)
Electro Magnetic Compatibility and Radio spectrum Matters (ERM); Elec-
tro Magnetic Compatibility (EMC) standard for radio equipment and ser-
vices; Part 1: Common Technical Requirements ETSI EN 301 489-7
V1.2.1 (2000-09)
IEC/EN 60950-1 (2001) Safety of information technology equipment (2000)
HC25_HO_v00.220 Page 9 of 39 2007-03-20 Confidential / Preliminary
Candidate Harmonized European Standard (Telecom munications serie s)
Electro Magnetic Compatibility and Radio spectrum Matters (ERM); Elec-
tro Magnetic Compatibility (EMC) standard for radio equipment and ser-
vices; Part 7: Specific conditions for mobile and portable radio and
ancillary equipment of digital cellular radio telecommunications systems
(GSM and DCS)
HC25 Hardware Interface Overview
1.3 Regulatory and Type Approval Information
12
Table 3: Standards of European type approval
EN 301 489-24 V1.2.1 Electromagnetic compatibility and Radio Spectrum Matters (ERM); Elec-
tromagnetic Compatibility (EMC) standard for radio equipment and ser-
vices; Part 24: Specific conditions for IMT-2000 CDMA Direct Spread
(UTRA) for Mobile and portable (UE) radio and ancillary equipment EN 301 908-01 V2.2.1 Electromagnetic compatibility and Radio spectrum Matters (ERM); Base
Stations (BS) and User Equipment (UE) for IMT-2000 Third Generation
cellular networks; Part 1: Harmonized EN for IMT-2000, introduction and
common requirements of article 3.2 of the R&T TE Direc tive EN 301 908-02 V2.2.1 Electromagnetic compatibility and Radio spectrum Matters (ERM); Base
Stations (BS) and User Equipment (UE) for IMT-2000 Third Generation
cellular networks; Part 2: Harmonized EN for IMT-2000, CDMA Direct
Spread (UTRA FDD) (UE) covering essential requirements of article 3.2 of
the R&TTE Directive 3GPP TS 34.124 Electromagnetic Compatibility (EMC) for mobile terminals and ancillary
equipment. 3GPP TS 34.121 Technical Specification Group Radio Access Network; Terminal conform-
ance specification; Radio transmission and reception (FDD)
s
3GPP TS 34.123-1 User Equipment (UE) conformance specification; Part 1: Protocol con-
formance specification. 3GPP TS 34.123-3 User Equipment (UE) conformance specification; Part 3: Abstract Test
Suites.
Table 4: Requirements of quality
IEC 60068 Environmental te stin g DIN EN 60529 IP codes
HC25_HO_v00.220 Page 10 of 39 2007-03-20 Confidential / Preliminary
HC25 Hardware Interface Overview

1.4 SAR requirements specific to portable mobiles

12
s
1.4 SAR requirements specific to portable mobiles
Mobile phones, PDAs or other portable transmitters and receivers incorporating a GSM module must be in accordance with the guidelines for human exposure to radio frequency energy. This requires the Specific Absorption Rate (SAR) of portable HC25 based applications to be evalu­ated and approved for compliance with national and/or international regulations.
Since the SAR value varies significantly with the individual product design manufacturers are advised to submit their product for approval if designed for portable use. For European and US markets the relevant directives are mentioned below. It is the responsibility of the manufacturer of the final product to verify whether or not further standards, recommendations or directives are in force outside these areas.
Products intended for sale on US markets
ES 59005/ANSI C95.1Considerations for evaluation of human exposure to Electromagnetic
Fields (EMFs) from Mobile Telecommunication Equipment (MTE) in the frequency range 30MHz - 6GHz
Products intended for sale on European markets
EN 50360 Product standard to demonstrate the compliance of mobile phones with
the basic restrictions related to human exposure to electromagnetic fields (300MHz - 3GHz)
IMPORTANT: Manufacturers of portable applications based on HC25 modules are required to have their final product certified and apply for their own FCC Grant and Industry Canada Certificate related to the specific portable mobile. See also Section 7.2.

1.4.1 SELV Requirements

The power supply connected to the HC25 module shall be in compliance with the SELV requirements defined in EN 60950-1.
HC25_HO_v00.220 Page 11 of 39 2007-03-20 Confidential / Preliminary
HC25 Hardware Interface Overview

1.5 Safety Precautions

12
s
1.5 Safety Precautions
The following safety precautions must be observed during all phases of the operation, usage, service or repair of any cellular terminal or mobile incorporating HC25. Manufacturers of the cellular terminal are advised to convey the following safety information to users and operating personnel and to incorporate these guidelines into all manuals supplied with the product. Fail­ure to comply with these precautions violates safety standards of design, manufacture and intended use of the product. Siemens AG assumes no liability for customer’s failure to comply with these precautions.
When in a hospital or other health care facility, observe the restrictions on the use of mobiles. Switch the cellular terminal or mobile off, if instructed to do so by the guide­lines posted in sensitive areas. Medical equipment may be sensitive to RF energy.
The operation of cardiac pacemakers, other implanted med ical equipment and hearing aids can be affected by interference from cellular terminals or mobiles placed close to the device. If in doubt about potential danger, contact the physician or the manufac­turer of the device to verify that the equipment is properly shielded. Pacemaker patients are advised to keep their h and-held mobile away from the pacemaker, while it is on.
Switch off the cellular terminal or mobile before boarding an aircraft. Make su re it can­not be switched on inadvertently. The operation of wirele ss appliances in an aircraft is forbidden to prevent interference with communications systems. Failure to observe these instructions may lead to the suspension or denial of cellular services to the offender, legal action, or both.
Do not operate the cellular terminal or mobile in the presence of flammable gases or fumes. Switch off the cellular terminal when you are near petrol stations, fuel d epots, chemical plants or where blasting operations are in progress. Oper ation of any electri­cal equipment in potentially explosive atmospheres can constitute a safety hazard.
Your cellular terminal or mobile receives and transmits radio frequency energy while switched on. Remember that interference can occur if it is used close to TV sets, radios, computers or inadequately shielded equipment. Follow any special re gulations and always switch off the cellular terminal or mobile wherever forbidden, or when you suspect that it may cause interference or danger.
Road safety comes first! Do not use a hand-held cellular terminal or mobile when driv­ing a vehicle, unless it is securely mounted in a holder for speakerphone operation. Before making a call with a hand-held terminal or mobile, park the vehicle. Speakerphones must be installed by qualified personnel. Faulty installation or opera­tion can constitute a safety hazard.
IMPORTANT! Cellular terminals or mobiles operate using radio signals an d cellular networks. Because of this, connection cannot be guaranteed at all times under all conditions. Therefore, you should never rely solely upon any wireless device for essential com­munications, for example emergency calls.
Remember, in order to make or receive calls, the cellular terminal or mobile must be switched on and in a service area with adequate cellular signal strength.
Some networks do not allow for emergency calls if certain network services or phone features are in use (e.g. lock functions, fixed dialing etc.). You may need to deactivate those features before you can make an emergency call. Some networks require that a valid SIM card be properly inserted in the cellu lar termi­nal or mobile.
HC25_HO_v00.220 Page 12 of 39 2007-03-20 Confidential / Preliminary
HC25 Hardware Interface Overview

2 Product Concept

15
2 Product Concept

2.1 Key Features at a Glance

Feature Implementation
General Frequency bands UMTS/HSDPA: Triple band, 850//1900/2100MHz
GSM/GPRS/EDGE: Quad band, 850/900/1800/1900MHz
GSM class Small MS
s
Output power (according to Release 99)
Power supply 3.2V < Physical Dimensions: 50mm x 34mm x 4.5mm
RoHS All hardware components fully compliant with EU RoHS Directive
HSDPA features 3GPP Release 5 3.6 Mb p s, UL 38 4 kb ps
Class 4 (+33dBm ±2dB) for EGSM850 Class 4 (+33dBm ±2dB) for EGSM900 Class 1 (+30dBm ±2dB) for GSM1800 Class 1 (+30dBm ±2dB) for GSM1900 Class E2 (+27dBm ± 3dB) for GSM 850 8-PSK Class E2 (+27dBm ± 3dB) for GSM 900 8-PSK Class E2 (+26dBm +3 /-4dB) for GSM 1800 8-PSK Class E2 (+26dBm +3 /-4dB) for GSM 1900 8-PSK Class 3 (+24dBm +1/-3dB) for UMTS 2100, WCDMA FDD BdI Class 3 (+24dBm +1/-3dB) for UMTS 1900,WCDMA FDD BdII Class 3 (+24dBm +1/-3dB) for UMTS 850, WCDMA FDD BdV
V
< 4.2V
BATT+
Weight: approx. 10g
UE CAT. [1-6], 11, 12 supported Compressed mode (CM) supported according to 3GPP TS25.212
UMTS features Release 99, June 2004, W-
CDMA FDD standard
HC25_HO_v00.220 Page 13 of 39 2007-03-20 Confidential / Preliminary
PS data rate – 384 kbps DL / 384 kbps UL CS data rate – 64 kbps DL / 64 kbps UL
HC25 Hardware Interface Overview
2.1 Key Features at a Glance
15
Feature Implementation
GSM / GPRS / EGPRS features Data transfer GPRS
Multislot Class 10
Full PBCCH support
Mobile Station Class B
Coding Scheme 1 – 4
EGPRS
Multislot Class 10
EDGE E2 power class for 8 PSK
Downlink coding schemes – CS 1-4, MCS 1-9
Uplink coding schemes – CS 1-4, MCS 1-9
BEP reporting
SRB loopback and test mode B
8-bit, 11-bit RACH
PBCCH support
1 phase/2 phase access procedures
Link adaptation and IR
NACC, extended UL TBF
Mobile Station Class B
CSD
V.110, RLP, non-transparent
9.6 kbps
s
SMS Point-to-point MT and MO
Cell broadcast
Text and PDU mode Fax Group 3; Class 1 Audio Audio speech codecs
GSM: AMR, EFR, FR, HR
3GPP: AMR
One ringing melody supported
CEPT supervisory tones supported
DTMF supported
6 audio modes: Approval, Router, Handset, Headset, Speakerphone an d
Transparent mode
TTY support selecting a dedicated audio mode
Download of audio parameters
Gains and volumes can be controlled by AT commands
Several additional ringing melodies
CEPT and ANSI supervisory tones supported
Software AT commands AT-Hayes GSM 07.05 and 07.07, Siemens
AT commands for RIL compatibility (NDIS/RIL)
Microsoft
TM
compatibility RIL / NDIS for Windows MobileTM SIM Application Toolkit SAT Class C Firmware update Firmware update from host application over USB.
HC25_HO_v00.220 Page 14 of 39 2007-03-20 Confidential / Preliminary
HC25 Hardware Interface Overview
2.1 Key Features at a Glance
15
Feature Implementation
Interfaces USB Supports a USB 2.0 Full Speed (12Mbit/s) device interface. Wakeup Control Signal pin to wake up an inactive USB Host into an active state. Status Signal pins to indicate network connectivity status. Audio 1 analog interface UICC interface Supported chip cards: SIM / UICC 3V, 1.8V Antenna 50Ohms. External antenna can be connected via antenna connector or
antenna pad (spring contact). Module interface 50-pin board-to-board connector Power on/off, Reset Power on/off Switch-on by hardware pin IGT
Switch-off by hardware pin IGT
Switch-off by AT command
s
Reset Orderly shutdown and reset by AT command
Emergency off by hardware pin EMERG_OFF and re start with hardware
pin IGT Emergency off Emergency off by hardware pin EMERG_OFF Evaluation kit DSB DSB75 Evaluation Board designed to test and type approve Siemens cel-
lular engines and provide a sample configura tion for application engineer-
ing. A special adapter is required to connect the module to the DSB75.
HC25_HO_v00.220 Page 15 of 39 2007-03-20 Confidential / Preliminary
HC25 Hardware Interface Overview

3 Application Interface

16
s
3 Application Interface
HC25 is equipped with a 50-pin board-to-board connector that connects to the external appli­cation and incorporates several sub-interfaces: power supply, USB interface, UICC/SIM inter­face, analog audio interface, as well as various status and control lines (see also Chapter 2).

3.1 Operating Modes

The table below briefly summarizes the various operating modes referred to in the following chapters.
Table 5: Overview of operating modes
Mode Function
Normal operation
GSM / GPRS / UMTS / HSDPA SLEEP
GSM IDLE Software is active. Once registered to the GSM network, paging with
GSM TALK/ GSM DATA
GPRS IDLE Module is attached and ready for GPRS data transfer, but no data is
GPRS DATA GPRS data transfer in progress. Power consumption depends on net-
EGPRS DATA EGPRS data transfer in progress. Power consumption depends on net-
UMTS / HSDPA IDLE
Power saving mode set automatically when no call is in progress and the USB connection is suspended by host or not present.
BTS is carried out in order to achieve synchrony with the GSM network. The repetition rate depends on the parameter BSPA_Multiframe. The module is ready to send and receive.
Connection between two subscribers is in progress. Power consump­tion depends on the GSM network coverage and several connectio n settings (e.g. DTX off/on, FR/EFR/HR, hopping sequences and antenna connection). The following applies when power is to be mea­sured in TALK_GSM mode: DTX off, FR and no frequency hopping, otherwise same as for IDLE measurements.
currently sent or received.
work settings (e.g. power control level), uplink / downlink data rates and GPRS configuration (e.g. used multislot settings).
work settings (e.g. power control level), uplink / downlink data rates and EGPRS configuration (e.g. used multislot settings).
Module is attached and ready for UMTS / HSDPA data transfer, but no data is currently sent or received.
UMTS TALK/ UMTS DATA
HSDPA DATA HSDPA data transfer in progress. Power consumption depends on net-
Power Down
HC25_HO_v00.220 Page 16 of 39 2007-03-20 Confidential / Preliminary
The internal power section is shut down. The SW on the module is not active. The interfaces are not accessible.
UMTS data transfer in progress. Power consumption depends on net­work settings (e.g. TPC Pattern) and data transfer rate.
work settings (e.g. TPC Pattern) and data transfer rate.
HC25 Hardware Interface Overview

4 Antenna Interface

22
s
4 Antenna Interface
The RF interface has an impedance of 50Ω. HC25 is capable of sustaining a total mismatch at the antenna connector or pad without any damage, even when transmitting at maximum RF power.
The external antenna must be matched properly to achieve best performance regarding radi­ated power, DC-power consumption, modulation accuracy and harmonic suppression. Antenna matching networks are not included on the HC25 PCB and should be placed in the host application.
Regarding the return loss HC25 provides the following values in the active band:
Table 6: Return loss in the active band
State of module Return loss of module Recommended return loss of application
Receive > Transmit not applicable > Idle <
The connection of the antenna or other equipment must be decoupled from DC voltage. This is necessary because the antenna connector is DC coupled to groun d via an in ductor for ESD protection.
Note: The antenna must be isolated for ESD protection (to withstand a voltage resistance up to 8kV air discharge).
8dB > 12dB
12dB
5dB not applicable

4.1 Antenna Installation

To suit the physical design of individual applications HC25 offers two alternative approaches to connecting the antenna:
Recommended approach: U.FL-R-SMT antenna connector from Hirose assembled on the top side of the PCB. See Section 4.3 for connector details.
Antenna pad and grounding plane placed on the bottom side. See Section 4.2.
The U.FL-R-SMT connector has been chosen as antenna reference point (ARP) for the Sie­mens reference equipment submitted to type approve HC25. All RF data specified throughout this manual are related to the ARP.
IMPORTANT: Both solutions can only be applied alternatively. This means, whenever an antenna is plugged to the Hirose connector, the pad must not be used. Vice versa, if the antenna is connected to the pad, then the Hirose connector must be left empty.
HC25_HO_v00.220 Page 17 of 39 2007-03-20 Confidential / Preliminary
HC25 Hardware Interface Overview

4.2 Antenna Pad

22
No matter which option you choose, ensure that the antenna pad does not come into contact with the holding device or any other components of the host application. It needs to be sur­rounded by a restricted area filled with air, which must also be reserved 1.4mm in height.
Figure 1: Restricted area around antenna pad (side and bottom view)
s
4.2 Antenna Pad
The antenna can be attached via contact springs. If you decide to use the antenna pad take into account that the pad has not been intended as
antenna reference point (ARP) for the Siemens HC25 type approval. The antenna pad is pro­vided only as an alternative option which can be used, for example, if the recommended Hirose connection does not fit into your antenna design.
Also, consider that according to the GSM recommendations TS 45.005 and TS 51.010-01 a 50Ω connector is mandatory for type approval measurements. This requires GSM devices with an integral antenna to be temporarily equipped with a suitable connector or a low loss RF cable with adapter.
HC25 material properties: HC25 PCB: FR4 Antenna pad: Gold plated pad
HC25_HO_v00.220 Page 18 of 39 2007-03-20 Confidential / Preliminary
HC25 Hardware Interface Overview

4.3 Antenna Connector

22
s
4.3 Antenna Connector
HC25 uses an ultra-miniature SMT antenna connector supplied from Hirose Ltd. The product name is:
U.FL-R-SMT
Figure 2: Mechanical dimensions of U.FL-R-SMT connector
Table 7: Product specifications of U.FL-R-SMT connector
Item Specification Conditions
Ratings Nominal impedance 50Ω Operating temp:-40°C to + 90°C
Operating humidity: max. 90% Rated frequency DC to 3GHz Mechanical characteristics Female contact
holding force Repetitive operation Contact resistance:
Vibration No momentary disconnectio ns of 1µs;
Shock No momentary disconnections of 1µs.
0.15N min Measured with a Ø 0.475 pin gauge
30 cycles of insertion and disengage-
Center 25mΩ Outside 15mΩ
No damage, cracks and looseness of parts
No damage, cracks and looseness of parts.
ment
Frequency of 10 to 100Hz, single
amplitude of 1.5mm, acceleration of
2
59m/s
each of the 3 axes
Acceleration of 735m/s
for 6 cycles in the direction of each of
the 3 axes
, for 5 cycles in the direction of
2
, 11ms duration
Environmental characteristics Humidity resistance No damage, cracks a nd looseness of
parts. Insulation resistance: 100MΩ min. at high humidity 500MΩ min. when dry
HC25_HO_v00.220 Page 19 of 39 2007-03-20 Confidential / Preliminary
Exposure to 40°C, humidity of 95% for
a total of 96 hours
HC25 Hardware Interface Overview
4.3 Antenna Connector
22
Table 7: Product specifications of U.FL-R-SMT connector
Item Specification Conditions
s
Temperature cycle No damage, cracks and looseness of
parts. Contact resistance: Center 25mΩ Outside 15mΩ
Salt spray test No excessive corrosion 48 hours continuous exposure to 5%
Table 8: Material and finish of U.FL-R-SMT connector and recommended plugs
Part Material Finish
Shell Phosphor bronze Silver plating Male center contact Brass Gold plating Female center con-
tact Insulator Plug: PBT
Phosphor bronze Gold plating
Receptacle: LCP
Temperature: +40°C 5 to 35°C
+90°C 5 to 35°C
Time: 30min within 5min 30min
within 5min
salt water
Black
Beige
Mating plugs and cables can be chosen from the Hirose U.FL Series. Examples are shown below and listed in Table 9. For latest product information please contact your Hirose dealer or visit the Hirose home page, for example http://www.hirose.com.
Figure 3: U.FL-R-SMT connector with U.FL-LP-040 plug
Figure 4: U.FL-R-SMT connector with U.FL-LP-066 plug
HC25_HO_v00.220 Page 20 of 39 2007-03-20 Confidential / Preliminary
HC25 Hardware Interface Overview
4.3 Antenna Connector
22
In addition to the connectors illustrated above, the U.FL-LP-(V)-040(01) version is offered as an extremely space saving solution. This plug is intended for use with extra fine cable (up to Ø 0.81mm) and minimizes the mating height to 2mm. See Figure 5 which shows the Hirose datasheet.
s
Figure 5: Specifications of U.FL-LP-(V)-040(01) plug
HC25_HO_v00.220 Page 21 of 39 2007-03-20 Confidential / Preliminary
HC25 Hardware Interface Overview
4.3 Antenna Connector
22
Table 9: Ordering information for Hirose U.FL Series
Item Part number HRS number
Connector on HC25 U.FL-R-SMT CL331-0471-0-10
s
Right-angle plug shell for Ø 0.81mm cable
Right-angle plug for Ø 0.81mm cable
Right-angle plug for Ø 1.13mm cable
Right-angle plug for Ø 1.32mm cable
Extraction jig E.FL-LP-N CL331-04441-9
U.FL-LP-040 CL331-0451-2
U.FL-LP(V)-040 (01) CL331-053-8-01
U.FL-LP-068 CL331-0452-5
U.FL-LP-066 CL331-0452-5
HC25_HO_v00.220 Page 22 of 39 2007-03-20 Confidential / Preliminary
HC25 Hardware Interface Overview

5 Electrical, Reliability and Radio Characteristics

26
s
5 Electrical, Reliability and Radio Characteristics

5.1 Absolute Maximum Ratings

The absolute maximum ratings stated in Table 10 are stress ratings under any conditions. Stresses beyond any of these limits will cause permanent damage to HC25.
Table 10: Absolute maximum ratings
Parameter Min Max Unit
Supply voltage BATT+ -0.3 4.5 V Voltage at digital pins in POWER DOWN mode -0.3 0.3 V Voltage at digital pins in normal operation -0.3 2.8 V Voltage at analog pins in POWER DOWN mode -0.3 0.3 V Voltage at analog pins in normal operation -0.3 2.5 V Voltage at STATSUSx pins -0.5 7.5 V VUSB -0.3 7.5 V USB_DP, USB_DN -0.3 7.5 V PWR_IND -0.3 10 V VDDLP -0.3 3.25 V
HC25_HO_v00.220 Page 23 of 39 2007-03-20 Confidential / Preliminary
HC25 Hardware Interface Overview

5.2 Operating Temperatures

s
26
5.2 Operating Temperatures
The values stated below are in compliance with GSM recommendation TS 51.010-01.
Table 11: Board temperature
Parameter Min Typ Max Unit
Operating temperature range -20 +25 +85 °C Automatic shutdown
Temperature measured on HC25 board
1.
Due to temperature measurement uncertainty, a tolerance on the stated shutdown thresholds may occur. The possible deviation is in the range of ± 3°C at the overtemperature limit and ± 5°C at the undertem­perature limit.
Table 11 shows the temperatures for automatic shutdown as measured by the on-board mea-
suring element NTC. The maximum allowable ambient temperature that causes the module to shut down depends on various conditions. The following tables Table 12 and Table 13 show sample lab environment conditions. Please be aware that the operating duration an d the max­imum ambient temperature will vary significantly for your application.
1
< -30 --- >+85 °C
Table 12: Sample operating conditions without forced air circulation (according to IEC 60068-2)
Mode Ambient
Voltage RF Power Operating
Temperature
GSM,
+65°C V
< 3.8V Max.
BATT+
GPRS/EDGE Class 8 WCDMA +55°C V WCDMA +65°C V GRPS/EDGE Class10 +65°C V WCDMA +65°C V
Table 13: Sample operating conditions with forced air circulation (air speed 0.9m/s)
Mode Ambient
< 3.4V < 10dBm
BATT+
< 3.4V < 0dBm
BATT+
< 3.8V Max. < 2min
BATT+
< 3.8V Max. < 2min
BATT+
Voltage RF Power Operating
Temperature
GSM,
+75°C V
< 3.8V Max.
BATT+
GPRS/EDGE Class 8 WCDMA +60°C V WCDMA +70°C V GRPS/EDGE Class 10 +65°C V WCDMA +60°C V
< 3.4V < 10dBm
BATT+
< 3.4V < 0dBm
BATT+
< 3.8V Max.
BATT+
< 3.4V Max.
BATT+
Duration
Duration
Note: Generally it is strongly recommended to implement additional measures to lead the heat out of the application, especially at maximum transmission power levels of WCDMA (24dBm), e.g. use of ground area for a heat sink or convection (see Section 6.1 for the ground area that may be used for a heat sink).
HC25_HO_v00.220 Page 24 of 39 2007-03-20 Confidential / Preliminary
HC25 Hardware Interface Overview

5.3 Storage Conditions

26
s
5.3 Storage Conditions
The conditions stated below are only valid for modules in their original packed state in weather protected, non-temperature-controlled storage locations. Normal storage time under these conditions is 12 months maximum.
Table 14: Storage conditions
Type Condition Unit Reference
Air temperature: Low
High
Humidity relative: Low
High Condens.
Air pressure: Low
High Movement of surrounding air 1.0 m/s IEC TR 60271-3-1: 1K4 Water: rain, dripping, icing and
frosting Radiation: Solar
Heat Chemically active substances Not recom-
Mechanically active substances Not recom-
Vibration sinusoidal:
Displacement Acceleration Frequency range
Shocks:
Shock spectrum Duration Acceleration
-40 +85
10 90 at 30°C 90-100 at 30°C
70 106
Not allowed --- ---
1120 600
mended
mended
1.5 5 2-9 9-200
semi-sinusoidal 1 50
°C ETS 300 019-2-1: T1.2, IEC 68-2-1 Ab
ETS 300 019-2-1: T1.2, IEC 68-2-2 Bb
%---
ETS 300 019-2-1: T1.2, IEC 68-2-56 Cb ETS 300 019-2-1: T1.2, IEC 68-2-30 Db
kPa IEC TR 60271-3-1: 1K4
IEC TR 60271-3-1: 1K4
2
W/m
mm m/s Hz
ms m/s
ETS 300 019-2-1: T1.2, IEC 68-2-2 Bb ETS 300 019-2-1: T1.2, IEC 68-2-2 Bb
IEC TR 60271-3-1: 1C1L
IEC TR 60271-3-1: 1S1
IEC TR 60271-3-1: 1M2
2
IEC 68-2-27 Ea
2
HC25_HO_v00.220 Page 25 of 39 2007-03-20 Confidential / Preliminary
HC25 Hardware Interface Overview

5.4 Reliability Characteristics

26
s
5.4 Reliability Characteristics
The test conditions stated below are an extract of the complete test specifications.
Table 15: Summary of reliability test conditions
Type of test Conditions Standard
Vibration Frequency range: 10-20Hz; acceleration: 3.1mm
amplitude Frequency range: 20-500Hz; acceleration: 5g Duration: 2h per axis = 10 cycles; 3 axes
Shock half-sinus Acceleration: 500g
Shock duration: 1msec 1 shock per axis 6 positions (± x, y and z)
Dry heat Temperature: +70 ±2×C
Test duration: 16h Humidity in the test chamber: < 50%
Temperature change (shock)
Damp heat cyclic High temperature: +55×C ±2×C
Cold (constant exposure)
Low temperature: -40×C ±2×C High temperature: +85×C ±2×C Changeover time: < 30s (dual chamber system) Test duration: 1h Number of repetitions: 100
Low temperature: +25×C ±2×C Humidity: 93% ±3% Number of repetitions: 6 Test duration: 12h + 12h
Temperature: -40 ±2×C Test duration: 16h
DIN IEC 68-2-6
DIN IEC 68-2-27
EN 60068-2-2 Bb ETS 300 019-2-7
DIN IEC 68-2-14 Na ETS 300 019-2-7
DIN IEC 68-2-30 Db ETS 300 019-2-5
DIN IEC 68-2-1
HC25_HO_v00.220 Page 26 of 39 2007-03-20 Confidential / Preliminary
HC25 Hardware Interface Overview

6 Mechanics

30
6 Mechanics

6.1 Mechanical Dimensions of HC25

Length:50.00mm Width: 34.00mm Height:4.5mm
RF Antenna
Connector
s
Ground
Ground
Pin 1
Pin 25
Pin 50
Pin 26
Ground (for Heat Sink)
Figure 6: HC25 – Top and bottom view
HC25_HO_v00.220 Page 27 of 39 2007-03-20 Confidential / Preliminary
HC25 Hardware Interface Overview
6.1 Mechanical Dimensions of HC25
30
s
Figure 7: Dimensions of HC25 (all dimensions in mm)
HC25_HO_v00.220 Page 28 of 39 2007-03-20 Confidential / Preliminary
HC25 Hardware Interface Overview

6.2 Mounting HC25 to the Application Platform

30
s
6.2 Mounting HC25 to the Application Platform
There are many ways to properly install HC25 in the host device. An efficient approach is to mount the HC25 PCB to a frame, plate, rack or chassis.
Fasteners can be M2 screws plus suitable washers, circuit board spacers, or customized screws, clamps, or brackets. In addition, the board-to-board connection can also be utilized t o achieve better support. To help you find appropriate spacers a list of selected screws and dis­tance sleeves for 3mm stacking height can be found in Section 8.2.
When using the holes the screws can be inserted from top or bottom. For proper grounding it is strongly recommended to use the large ground plane on the bottom
of board in addition to the five GND pins of the board-to-board connector. The ground plane may also be used to attach cooling elements, e.g. a heat sink or thermally conductive tape. Please take care that attached cooling elements do not touch the antenna pads on the mod­ule’s bottom side, as this may lead a short-circuit.
To prevent mechanical damage, be careful not to force, bend or twist the module. Be sure it is positioned flat against the host device (see also Section 8.3 with mounting advice sheet).

6.3 Board-to-Board Application Connector

This section provides specifications for the 50-pin board-to-board (B2B) connector used to con­nect HC25 to the host application.
For the module’s external interface the following connector series has been chosen: Supplier: Hirose ( www.hirose.com Type: DF12C (3.0)-50DS-0.5V (SlimStack Receptacle) Height: 3.0 mm
Table 16: Electrical and mechanical characteristics of the board-to-board connector
Parameter Specification (50-way connector)
Number of Contacts 50 Quantity delivered 2000 Connectors per Tape & Reel Voltage 50V Current Rating 0.4A max per contact Resistance 0.05 Ohm per contact
)
Dielectric Withstanding Voltage 150V RMS AC for 1min Operating Temperature -40°C...+85°C Contact Material phosphor bronze finish: solder plating Insulator Material PPS, deep brown / Polyamide, beige FFC/FPC Thickness 0.3mm ±0.05mm (0.012" ±0.002") Maximum connection cycles 20 (@ 50mOhm max) Cable FFC (Flat Flexible Cable), max. length 150mm from SIM
interface
HC25_HO_v00.220 Page 29 of 39 2007-03-20 Confidential / Preliminary
HC25 Hardware Interface Overview
6.3 Board-to-Board Application Connector
30
A recommended corresponding board-to-board connector series for external applications is: Supplier: Hirose ( www.hirose.com Type: DF12x-50DP-0.5V (SlimStack Header) Height: 3.0 – 5.0 mm
For Hirose sales contacts see Chapter 8. Note: There is no inverse polarity protection for the board-to-board connector. It is therefore
very important that the board-to-board connector is connected correctly to the host application, i.e., pin1 must be connected to pin1, pin2 to pin 2, etc. Pin assignments are listed in Section
5.5, pin locations are shown in Figure 6.
)
s
Figure 8: Mechanical dimensions of the board-to-board connector
HC25_HO_v00.220 Page 30 of 39 2007-03-20 Confidential / Preliminary
HC25 Hardware Interface Overview

7 Reference Approval

32
s
7 Reference Approval

7.1 Reference Equipment for Type Approval

The Siemens reference setup submitted to type approve HC25 consists of the following com­ponents:
Siemens HC25 cellular engine
Development Support Box DSB75 and HC15/HC25-DSB75-Adapter for mounting the HC25 module
SIM card reader integrated on DSB75
U.FL-LP antenna cable
Handset type Votronic HH-SI-30.3/V1.1/0
•PC as MMI
Figure 9: Reference equipment for Type Approval
HC25_HO_v00.220 Page 31 of 39 2007-03-20 Confidential / Preliminary
HC25 Hardware Interface Overview

7.2 Compliance with FCC Rules and Regulations

32
s
7.2 Compliance with FCC Rules and Regulations
The Equipment Authorization Certification for the Siemens reference application described in
Section 7.1 will be registered under the following identifiers:
FCC Identifier: QIPHC25 Industry Canada Certification Number: 267W-HC25 Granted to Siemens AG
Manufacturers of mobile or fixed devices incorporating HC25 modules are authorized to use the FCC Grants and Industry Canada Certificates of the HC25 modules for their own final prod­ucts according to the conditions referenced in these documents. In this case, the FCC label of the module shall be visible from the outside, or the host device shall bear a second label stating "Contains FCC ID QIPHC25".
IMPORTANT: Manufacturers of portable applications incorporating HC25 modules are required to have their final product certified and apply for their own FCC Grant and Industry Canada Certificate related to the specific portable mobile. This is mandatory to meet the SAR requirements for por­table mobiles (see Section 1.4 for detail).
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to wh ich the rece iver is connected.
Consult the dealer or an experienced radio/TV technician for help.
HC25_HO_v00.220 Page 32 of 39 2007-03-20 Confidential / Preliminary
HC25 Hardware Interface Overview

8 Appendix

39
s
8 Appendix

8.1 List of Parts and Accessories

Table 17: List of parts and accessories
Description Supplier Ordering information
HC25 Siemens Standard module (Siemens IMEI)
Siemens ordering number: L30960-N1050-A100 Customer IMEI mode:
Siemens Ordering number: L30960-N1060-A100 Siemens Car Kit Portable Siemens Siemens ordering number: L36880-N3015-A117 DSB75 Support Box Siemens Siemens ordering number: L36880-N8811-A100 HC15/HC25-DSB75-Adapter Siemens Siemens ordering number: L30960-N1001-A100 Votronic Handset VOTRONIC Votronic HH-SI-30.3/V1.1/0
VOTRONIC
Entwicklungs- und Produktionsgesellschaft für elek-
tronische Geräte mbH
Saarbrücker Str. 8
66386 St. Ingbert
Germany
Phone: +49-(0)6 89 4 / 92 55-0
Fax: +49-(0)6 89 4 / 92 55-88
e-mail: contact@votronic.com SIM card holder incl. push
button ejector and slide-in tray
Board-to-board connector Molex Sales contacts are listed in Table 18. Antenna connector Hirose Sales contacts are listed in Table 19.
Molex Ordering numbers: 91228
91236
Sales contacts are listed in Table 18.
HC25_HO_v00.220 Page 33 of 39 2007-03-20 Confidential / Preliminary
HC25 Hardware Interface Overview
8.1 List of Parts and Accessories
39
Table 18: Molex sales contacts (subject to change)
s
Molex For further information please click:
http://www.molex.com
Molex China Distributors Beijing, Room 1319, Tower B, COFCO Plaza No. 8, Jian Guo Men Nei Street, 100005 Beijing P.R. China Phone: +86-10-6526-9628 Phone: +86-10-6526-972 Phone: +86-10-6526-9731 Fax: +86-10-6526-9730
Table 19: Hirose sales contacts (subject to change)
Hirose Ltd. For further information please click:
http://www.hirose.com
Molex Deutschland GmbH Felix-Wankel-Str. 11 4078 Heilbronn-Biberach Germany Phone: +49-7066-9555 0 Fax: +49-7066-9555 29 Mail: mxgermany@molex.com
Molex Singapore Pte. Ltd. Jurong, Singapore Phone: +65-268-6868 Fax: +65-265-6044
Hirose Electric (U.S.A.) Inc 2688 Westhills Court Simi Valley, CA 93065 U.S.A. Phone: +1-805-522-7958 Fax: +1-805-522-3217
American Headquarters Lisle, Illinois 60532 U.S.A. Phone: +1-800-78MOLEX Fax: +1-630-969-1352
Molex Japan Co. Ltd. Yamato, Kanagawa, Japan Phone: +81-462-65-2324 Fax: +81-462-65-2366
Hirose Electric GmbH Herzog-Carl-Strasse 4 73760 Ostfildern Germany Phone: +49-711-456002-1 Fax: +49-711-456002-299 Email info@hirose.de
Hirose Electric UK, Ltd Crownhill Business Centre 22 Vincent Avenue, Crownhill Milton Keynes, MK8 OAB Great Britain Phone: +44-1908-305400 Fax: +44-1908-305401
Hirose Electric Co., Ltd. 5-23, Osaki 5 Chome, Shinagawa-Ku Tokyo 141 Japan Phone: +81-03-3491-9741 Fax: +81-03-3493-2933
Hirose Electric Co., Ltd. European Branch First class Building 4F Beechavenue 46 1119PV Schiphol-Rijk Netherlands Phone: +31-20-6557-460 Fax: +31-20-6557-469
HC25_HO_v00.220 Page 34 of 39 2007-03-20 Confidential / Preliminary
HC25 Hardware Interface Overview

8.2 Fasteners and Fixings for Electronic Equipment

39
s
8.2 Fasteners and Fixings for Electronic Equipment
This section provides a list of suppliers and manufacturers offering fasteners and fixings for electronic equipment and PCB mounting. The content of this section is designed to offer basic guidance to various mounting solutions with no warranty on the accuracy and sufficiency of the information supplied. Please note that the list remains preliminary although it is going to be updated in later versions of this document.

8.2.1 Fasteners from German Supplier ETTINGER GmbH

Sales contact: ETTINGER GmbH http://www.ettinger.de/main.cfm Phone: +49-81-046623-0 Fax: +49-81-046623-99
The following tables contain only article numbers and basic parameters of the listed compo­nents. For further detail and ordering information please contact Ettinger GmbH.
Please note that some of the listed screws, spacers and nuts are delivered with the DSB75 Support Board. See comments below.
Article number: 05.71.038 Spa ce r - Alum in um /
Wall thickness = 0.8mm
Length 3.0mm Material AlMgSi-0,5 For internal diameter M2=2.0-2.3 Internal diameter d = 2.4mm External diameter 4.0mm Vogt AG No. x40030080.10
HC25_HO_v00.220 Page 35 of 39 2007-03-20 Confidential / Preliminary
HC25 Hardware Interface Overview
8.2 Fasteners and Fixings for Electronic Equipment
39
s
Article number: 07.51.403 Insulating Spacer for M2
Self-gripping Length 3.0mm Material Polyamide 6.6 Surface Black Internal diameter 2.2mm External diameter 4.0mm Flammability rating UL94-HB
1.
2 spacers are delivered with DSB75 Support Board
1
Article number: 05.11.209 Threaded Stud M2 .5 - M2 Type E /
External thread at both ends Length 3.0mm Material Stainless steel X12CrMoS17 Thread 1 / Length M2.5 / 6.0mm Thread 2 / Length M2 / 8.0mm Width across flats 5 Recess yes Type External / External
HC25_HO_v00.220 Page 36 of 39 2007-03-20 Confidential / Preliminary
HC25 Hardware Interface Overview
8.2 Fasteners and Fixings for Electronic Equipment
39
Article number: 01.14.131 Screw M21
DIN 84 - ISO 1207 Length 8.0mm Material Steel 4.8 Surface Zinced A2K Thread M2 Head diameter D = 3.8mm Head height 1.30mm Type Slotted cheese head screw
s
1.
2 screws are delivered with DSB75 Support Board
Article number: 01.14.141 Screw M2
DIN 84 - ISO 1207 Length 10.0mm Material Steel 4.8 Surface Zinced A2K Thread M2 Head diameter D = 3.8mm Head height 1.30mm Type Slotted cheese head screw
HC25_HO_v00.220 Page 37 of 39 2007-03-20 Confidential / Preliminary
HC25 Hardware Interface Overview

8.3 Mounting Advice Sheet

39
s
Article number: 02.10.011 Hexagon Nut
DIN 934 - ISO 4032 Material Steel 4.8 Surface Zinced A2K Thread M2 Wrench size / Ø 4 Thickness / L 1.6mm Type Nut DIN/UNC, DIN934
1.
2 nuts are delivered with DSB75 Support Board
1
8.3 Mounting Advice Sheet
To prevent mechanical damage, be careful not to force, bend or twist the module. Be sure it is positioned flat against the host device. The advice sheet on the next page shows a number of examples for the kind of bending that may lead to mechanical damage of the module.
HC25_HO_v00.220 Page 38 of 39 2007-03-20 Confidential / Preliminary
HC25 Hardware Interface Overview
8.3 Mounting Advice Sheet
39
s
HC25_HO_v00.220 Page 39 of 39 2007-03-20 Confidential / Preliminary
Loading...