Gema OptiFlex A1, AS07 Operating Instructions And Spare Parts List

En
Translation of the original operating instructions
Operating instructions and spare parts list
OptiFlex A1
Control system
(AS07 type)
V 12/13
Documentation - OptiFlex A1 (AS07) Control system
© Copyright 2012 Gema Switzerland GmbH
All rights reserved.
This publication is protected by copyright. Unauthorized copying is prohibited by law. No part of this publication may be reproduced, photocopied, translated, stored on a retrieval system or transmitted in any form or by any means for any purpose, neither as a whole nor partially, without the express written consent of Gema Switzerland GmbH.
MagicCompact, MagicCylinder, MagicPlus, MagicControl, OptiFlex, OptiControl, OptiGun, OptiSelect, OptiStar and SuperCorona are registered trademarks of Gema Switzerland GmbH.
OptiFlow, OptiCenter, OptiMove, OptiSpeeder, OptiFeed, OptiSpray, OptiSieve, OptiAir, OptiPlus, OptiMaster, MultiTronic, EquiFlow, Precise Charge Control (PCC), Smart Inline Technology (SIT) and Digital Valve Control (DVC) are trademarks of Gema Switzerland GmbH.
All other product names are trademarks or registered trademarks of their respective holders.
Reference is made in this manual to different trademarks or registered trademarks. Such references do not mean that the manufacturers concerned approve of or are bound in any form by this manual. We have endeavored to retain the preferred spelling of the trademarks, and registered trademarks of the copyright holders.
To the best of our knowledge and belief, the information contained in this publication was correct and valid on the date of publication. Gema Switzerland GmbH makes no representations or warranties with respect to the contents or use of this publication, and reserves the right to revise this publication and make changes to its content without prior notice.
For the latest information about Gema products, visit www.gemapowdercoating.com.
For patent information, see www.gemapowdercoating.com/patents or www.gemapowdercoating.us/patents.
Printed in Switzerland
Gema Switzerland GmbH Mövenstrasse 17 9015 St.Gallen Switzerland
Phone: +41-71-313 83 00 Fax.: +41-71-313 83 83
E-Mail: info@gema.eu.com
V 12/13
OptiFlex A1 (AS07) Table of contents 1
Table of contents
General safety regulations 3
Safety symbols (pictograms) ................................................................................... 3
Proper use ............................................................................................................... 3
Product-specific safety measures ........................................................................... 4
OptiFlex A1 Control system ....................................................................... 4
About this manual 5
General information ................................................................................................ 5
Function description 7
Field of application .................................................................................................. 7
Scope of delivery .................................................................................................... 7
OptiFlex A1 Control system - components ............................................................. 8
OptiFlex A1 Control system - possible configurations ............................................ 9
Automatic equipment without reciprocator ................................................. 9
Automatic equipment with reciprocator ...................................................... 9
Technical data 11
OptiFlex A1 Control system .................................................................................. 11
Electrical data .......................................................................................... 11
Pneumatic data ........................................................................................ 11
Dimensions .............................................................................................. 11
Commissioning 13
Set-up and assembly ............................................................................................ 13
Assembly notes ........................................................................................ 13
OptiFlex A1 Control cabinet ..................................................................... 14
Start-up ................................................................................................................. 14
General information ................................................................................. 14
Power supply............................................................................................ 14
Compressed air ........................................................................................ 15
Spare parts list 17
Ordering spare parts ............................................................................................. 17
OptiFlex A1 control cabinet - spare parts list ........................................................ 18
OptiFlex A1 control cabinet - spare parts ............................................................. 19
OptiFlex A1 - Pneumatics (systems without OptiAir CA10) – spare parts list ...... 20
OptiFlex A1 - Pneumatics (systems without OptiAir CA10) – spare parts ............ 21
V 12/13
OptiFlex A1 (AS07) General safety regulations 3
General safety regulations
This chapter sets out the fundamental safety regulations that must be followed by the user and third parties using the OptiFlex A1 (AS07) control system.
These safety regulations must be read and understood in full before the OptiFlex A1 (AS07) control system is put into operation.
Safety symbols (pictograms)
The following warnings with their meanings can be found in the Gema Switzerland operating instructions. The general safety precautions must also be followed as well as the regulations in the operating instructions.
DANGER!
Danger due to electrically live or moving parts. Possible consequences: death or serious injury
WARNING!
Improper use of the equipment could damage the machine or cause it to malfunction. Possible consequences: minor injuries or damage to equipment
INFORMATION!
Useful tips and other information
Proper use
1. The OptiFlex A1 (AS07) control system is built to the latest specification and conforms to the recognized technical safety regulations and is designed for the normal application of powder coating.
2. Any other use is considered non-compliant. The manufacturer shall not be liable for damage resulting from such use; the user bears sole responsibility for such actions. If the OptiFlex A1 (AS07) is to be used for other purposes or other substances outside of our guidelines then Gema Switzerland GmbH should be consulted.
V 12/13
4 General safety regulations OptiFlex A1 (AS07)
3. Observance of the operating, service and maintenance instructions specified by the manufacturer is also part of conformity of use. The OptiFlex A1 (AS07) should only be used, maintained and started up by trained personnel, who are informed about and are familiar with the possible hazards involved.
4. Start-up (i.e. the execution of a particular operation) is forbidden until it has been established that the OptiFlex A1 (AS07) has been set up and wired according to the guidelines for machinery (2006/42 EG). EN 60204-1 (machine safety) must also be observed.
5. Unauthorized modifications to the OptiFlex A1 (AS07) exempt the manufacturer from any liability from resulting damage.
6. The relevant accident prevention regulations, as well as other generally recognized safety regulations, occupational health and structural regulations are to be observed.
7. Furthermore, the country-specific safety regulations also must be observed.
Explosion protection
Protection
type
Temperature class
II 3D
IP54
T6 (zone 21) T4 (zone 22)
Product-specific safety measures
- Installation work performed by the customer must be carried
out according to local regulations.
- Before starting up the plant a check must be made that no
foreign objects are in the booth or in the ducting (input and exhaust air)
- All components must be grounded according to the local
regulations before start-up.
OptiFlex A1 Control system
The OptiFlex A1 (AS07) control system is a constituent part of the equipment and is therefore integrated in the system's safety concept.
If it is to be used in a manner outside the scope of the safety concept, then corresponding measures must be taken.
NOTE: For further information, see the more detailed Gema safety
regulations!
V 12/13
OptiFlex A1 (AS07) About this manual 5
About this manual
General information
These operating manual contains all important information which you require for the working with the OptiFlex A1 (AS07) control systemOptiFlex-A1-de.doc. It will safely guide you through the start-up process and give you references and tips for the optimal use of your new powder coating system.
Information about the functionality of the individual system components ­booth, gun control unit, manual gun or powder injector - should be referenced to their enclosed corresponding documents.
DANGER: Working without operating instructions Working without operating instructions or with individual pages
from the operating instructions may result in damage to property and personal injury if relevant safety information is not observed.
Before working with the device, organize the required documents and
read the section "Safety regulations".
Work should only be carried out in accordance with the instructions of
the relevant documents.
Always work with the complete original document.
V 12/13
OptiFlex A1 (AS07) Function description 7
Function description
Field of application
The OptiFlex A1 Control system was especially designed to meet the requirements of production, and also the custom electrostatic coating requirements.
The flexible, modular structure of the OptiFlex A1 Control system is readily adaptable to any modifications in the installation.
Scope of delivery
The scope of delivery depends on the type and the number of installed control units (see therefore chapter "OptiFlex A1 Control system ­components").
V 12/13
8 Function description OptiFlex A1 (AS07)
OptiFlex A1 Control system - components
OptiFlex A1 control cabinet Function
- Equipment main switch
- Key switch for switching on/off the guns
- Interlocks on the mounting plate
- Max. 15 places for gun or axis control units
- Pneumatic functions by OptiAir CA10
- Option: connectable LM02 Level sensor
OptiStar CG08 Gun control unit Function
- OptiStar CG08 standard gun control unit
- Max. 250 stored programs possible
- DVC (Digital Valve Control)
- PCC (Precise Charge Control)
OptiMove CR07 Axis control unit Function
- Axis control unit for ZA0x Reciprocator
- Pendulum operating mode or sequence programs
- Max. 255 stored programs possible
OptiAir CA10-A/B pneumatic-fluidizing unit Function
- Air distribution for OptiFlex A1 and gun control units
- Airmover control unit
- Fluidization in the powder hopper
- Manual prefluidization
OptiAir CA10-C pneumatic unit Function
- Air distribution for OptiFlex A1 and gun control units
LM02 Level sensor Function
- Level detection in the powder hopper
V 12/13
OptiFlex A1 (AS07) Function description 9
OptiFlex A1 Control system - possible configurations
Automatic equipment without reciprocator
Automatic equipment with reciprocator
Control units
Fluidized powder hopper with injector and Airmover
Powder guns
Control units Reciprocator with guns
Fluidized powder hopper with injector and Airmover
V 12/13
OptiFlex A1 (AS07) Technical data 11
Technical data
OptiFlex A1 Control system
Electrical data
OptiFlex A1 (AS07)
Main input voltage 100-240 VAC
Device input voltage
100-240 VAC
(for gun control units)
200-240 VAC
(for axis control units)
Frequency 50/60 Hz
Input power (sum of the power values of all control units)
40 VA per gun control unit
1.1 kVA per axis control unit
Protection type (control units) IP54
Temperature range (operation) 10-40°C / 50-104 °F
Pneumatic data
OptiFlex A1 (AS07)
Min. input pressure 6 bar / 87 psi
Max. input pressure 8 bar / 116 psi
Max. water vapor content of the compressed air
1.3 g/m³
Max. oil vapor content of the compressed air
0.1 mg/m³
Total air consumption
8 Nm³/h per gun (plus powder
hopper air requirement)
Dimensions
OptiFlex A1 (AS07)
Width 600 mm
Depth 697 mm
Height max. 1838 mm
NOTE: Further specifications will be found in the corresponding manuals
of the components!
V 12/13
OptiFlex A1 (AS07) Commissioning 13
Commissioning
Set-up and assembly
Assembly notes
After unpacking and installing the OptiFlex system, the control cabinet is to be fitted to the floor with the supplied steel bolts. The mounting holes are located in the Z-profiles on both cabinet sides.
The internal connections have already been made at the factory. The control unit connections to the external plant parts must be done at the start-up.
The connection possibilities for the individual control units are found in the corresponding operating manuals.
When connecting, pay attention particularly to the length and the radii of the pneumatics hoses!
Set-up and assembly
Compressed ai
r
inpu
t
Main valve
Terminal block
recommended
V 12/13
14 Commissioning OptiFlex A1 (AS07)
OptiFlex A1 Control cabinet
Combination examples:
- 1 OptiAir with max. 15 OptiStar control units
- 1 OptiAir with 2 OptiMove and 13 OptiStar control units
Start-up
General information
These general information serves to obtain an overview of the possible OptiFlex A1 system combinations.
Detailed information will be found in the corresponding operating manuals!
Power supply
- As mains supply, a single phase alternating current is
required
- If the OptiStar CG08 gun control unit is used, it can be
connected to tensions of 100-240 VAC
- If the OptiMove reciprocator control unit is used, a mains
voltage of 230 VAC must be available
- Frequencies of 50 or 60 Hz can be used
- The input power value is evident in the technical data
section
- All electrical components are implemented in accordance
to IP54 protection type regulations
V 12/13
OptiFlex A1 (AS07) Commissioning 15
NOTE: The OptiFlex A1 powder coating control system may can be switched on only if the booth is in operation! If the booth switches off, the control system must also switch off!
Compressed air
- The OptiAir pneumatic-fluidizing unit is always used as
main compressed air input, compressed air distributor and for fluidizing air monitoring
- The OptiFlex A1 Control system just requires a
connection to the main compressed air system
- The compressed air values are evident in the technical
data section
Air requirement with increased powder output
The control system offers the possibility to work with increased powder output in sufficiently dimensioned compressed air systems. The pressure
regulator on the filter unit is preset by factory to 5.5 bar with an air flow of
5 m
3
/h per control unit. If another value is set on the pressure regulator,
then the system parameter 2 on each OptiStar Control unit needs to be
adjusted according to the following instructions:
NOTE: In order to achieve the largest accuracy, the air pressure is to be set
during operation by average compressed air consumption!
> 5 s
Compressed air setting - parameter setting O
p
tiStar CG08 automatic gun control unit
Conversion bar-psi
5.5 bar = 80 psi
6.0 bar = 87 psi
6.5 bar = 94 psi
5.5
6.0
6.5
V 12/13
OptiFlex A1 (AS07) Spare parts list 17
Spare parts list
Ordering spare parts
When ordering spare parts for powder coating equipment, please indicate the following specifications:
- Type and serial number of your powder coating
equipment
- Order number, quantity and description of each spare
part
Example:
- Type OptiFlex A1 (AS07)
Serial number 1234 5678
- Order no. 203 386, 1 piece, Clamp - Ø 18/15 mm
When ordering cable or hose material, the required length must also be given. The spare part numbers of this bulk stock is always marked with
an *. Wearing parts are always marked with a #.
All dimensions of plastic hoses are specified with the external and internal diameter:
Example:
Ø 8/6 mm, 8 mm outside diameter (o/d) / 6 mm inside diameter (i/d)
WARNING! Only original Gema spare parts should be used, because the
explosion protection will also be preserved that way. The use of spare parts from other manufacturers will invalidate the Gema guarantee conditions!
V 12/13
18 Spare parts list OptiFlex A1 (AS07)
OptiFlex A1 control cabinet - spare parts list
1 OptiStar CG08 Gun control unit - see corresponding operating manual
2 OptiMove CR07 Axis control unit - see corresponding operating manual
3 OptiAir CA10-A Pneumatic-fluidizing unit - see corresponding operating manual
OptiAir CA10-B Pneumatic-fluidizing unit - see corresponding operating manual
Pneumatic unit (systems without OptiAir CA10) - see corresponding spare parts list
4 Main switch – see enclosed wiring diagram
5 Key switch – see enclosed wiring diagram
6 Lock - complete 262 110
Plate (for pos. 6, not shown) 262 145
Key (for pos. 6, not shown) 259 908
7 Roof 1008 813
8 Standard module 1008 806
9 Support 1007 873
10 Crossbeam 1008 812
11
Mounting plate, system-dependent – see enclosed wiring diagram
NOTE: Further specifications will be found in the corresponding manuals
and spare parts list of the components!
V 12/13
OptiFlex A1 (AS07) Spare parts list 19
OptiFlex A1 control cabinet - spare parts
OptiFlex A1 control cabinet - spare parts
5
9
6
4
10
7
8
3
2
1
11
V 12/13
20 Spare parts list OptiFlex A1 (AS07)
OptiFlex A1 - Pneumatics (systems without OptiAir CA10) – spare parts list
9 Plug cap - 1"a 258 679
10 Compressed air distributor – 18-fold 1008 805
11 Plug - Ø 8 mm 238 023
12 Pressure gauge - 1-10 bar, 1/8"a 259 179
13 Adapter nipple - 1"a-1/2"i 252 875
14 Screw-in nipple - 1/4"a-Ø 10 mm 266 990
15 Double nipple - 1/2"a-1/2"a 243 540
17 Solenoid valve - without pos. 17.1 1005 120
17.1 Valve coil - 230 VAC (for pos. 17) 1005 117
17.2 Valve coil - 110 VAC (for pos. 17) 1005 116
17.3
Valve coil - 24 VDC (for pos. 17)
1005 119
26 Hose connector - Ø 17 mm, 1/2"a 223 069
Pressure regulator unit - complete, pos. 30-34
1010 400
30 R/F unit- 0.5-8.5 bar, 1/2"i 1005 841
31 Elbow joint - 1/2"a-1/2"i 223 166
32 Pipe nipple - 1/2"a, 90 mm 1008 807
33 Adapter - 1/2"i-1/2"i 202 622
34 Double nipple - 1/2"a-1/2"a, divisible 243 582
V 12/13
OptiFlex A1 (AS07) Spare parts list 21
OptiFlex A1 - Pneumatics (systems without OptiAir CA10) – spare parts
OptiFlex A1 - Pneumatics (systems without OptiAir CA10) – spare parts
9
11
31 31
30
26
12
10
14
32
33
31
17
34
13
15