Product Technical Information
July 17, 2020
Data shown is for the current revision model #. Ensure your nameplate model # matches.
Accessory Connection Diagrams
Performance Characteristics

Model Number:5KS444XAJ6408A
Enclosure is Totally Enclosed Fan-Cooled
Stamped Nameplate Notes:
IEEE-STD-841-2009
VERTICAL 841
DE BRG 85BC02J30, ODE BRG 130BT03MD00
INVERTER DUTY PER NEMA MG1 PART 31
ALTERNATE RATING FOR PWM CONTROL:1.0SF 40C AMBIENT
VAR TORQUE RANGE 0-60 HZ
GE SELF DECLARED CLASS I DIV 2 MOTOR
MAX EXPOSED INTERNAL AND EXTERNAL SURFACE
TEMPERATURES UNDER USUAL SERVICE CONDITIONS
AT 1.00 S.F. DO NOT EXCEED 200 DEG C
API 610 12TH EDITION SHAFT DIMENSIONS

Model Number:5KS444XAJ6408A
4 POLE,VERT SOLID SHAFT HIGH THRUST (1D)
PAINTED FRAME ID & SHAFT,
FAN COVER INSIDE & ODE E/S OUTSIDE
700 CU IN - 3.00" NPT
BEARING LIFE 8760 HRS AT 13095 LB THRUST
BEARING LIFE 26280 HRS AT 9706 LB THRUST
INPRO SEAL LOWER END
OIL RESISTANT SLEEVING ON LEADS
ROUTINE TEST REPORT AND 5 POINT VIBRATION TEST
REPORT INCLUDED IN C/B
COPPER WASHER UNDER HEADS OF BEARING CAP BOLTS,
APPLY TITE-SEAL (A50CD427A) ON BEARING CAP SCREWS,
RABBETS AND PLUG THREADS.
STAINLESS STEEL T-DRAIN.
FRAME GROUND PAD
ACTUAL EFFICIENCY =
RCF: XXXX CPM AT C/BOX SIDE, XXXX CPM AT
90 DEG FROM C/ BOX SIDE

Model Number:5KS444XAJ6408A
Performance Characteristics
1st Winding 1st Connection
This motor is capable of two cold or one hot start with a maximum connected load inertia of 1876 Lb-Ft Sq (78.98 Kg-meter
Sq)at 100% voltage, where the load torque varies with the square of the speed. Acceleration time with maximum inertia
and the above load type is 23 seconds. Safe stall time at 100% voltage is 55 seconds cold, 27 seconds hot. Rotor inertia
is 47.44 Lb-Ft Sq (2 Kg-meter Sq).

Model Number: 5KS444XAJ6408A

Model Number: 5KS444XAJ6408A

Model Number: 5KS444XAJ6408A
Conduit & Accessories Box Assembly