Product Technical Information
July 15, 2020
Data shown is for the current revision model #. Ensure your nameplate model # matches.
Accessory Connection Diagrams
Performance Characteristics
Model Number:5KS447DAJ6022D
Enclosure is Weather Protected One
NEMA ENCLOSURE WP-I, CSA ENCL DP
HTR LDS HE1-HE2 115V 145W
ROT CCW FACING ODE LEAD/PH SEQ 1-2-3/1-2-3
THERMOSTAT LEADS TB1-TB2 TRIP
INVERTER DUTY PER NEMA MG1 PART 31
ALTERNATE RATING FOR PWM CONTROL:1.0SF 40C AMBIENT
VAR TORQUE RANGE 5 -60 HZ
UPPER BRG LUBE OIL: 10.2 QTS
0 DEG C TO 40 DEG C : ISO 32(MINERAL OR SYNTHETIC)
-15 DEG C TO 0 DEG C : ISO 32 SYNTHETIC
SUITABLE FOR 300 HP, 380V, 50 HZ WITH
409.0 AMPS AND 1486 RPM AT 1.0 SF
Model Number:5KS447DAJ6022D
4P, VERT HOLLOW SHAFT HIGH THRUST (2D)
C/BOX 1260 CU IN - 2(4.00" NPT)
C/B GRD PLATE
SLINGER DE
OIL RESISTANT SLEEVING ON LEADS
(3)N.C. CL.F TRIP TSTAT LDS TO MAIN CONDUIT BOX
115V HTR LDS TO MAIN CONDUIT BOX
GROUND PAD
INSULATED LOWER HALF COUPLING AT UPPER END
SHAFT GROUNDING RING MOUNTED ON LOWER END BRG CAP
BEARING LIFE 8760 HRS AT 22270 LB THRUST
PART WINDING START
CG:25.10 IN FROM P-BASE FACE,STAT DEF:= 0.005 IN
RCF: 2581 CPM
NON-REVERSE BALL CARRIER,
BOLTED COUPLING, BX = 1.688", EW = .375"