Product Technical Information
July 10, 2020
Data shown is for the current revision model #. Ensure your nameplate model # matches.
Accessory Connection Diagrams
Performance Characteristics

Model Number:5KS513SAA199ZGP
Enclosure is Totally Enclosed Fan-Cooled
Stamped Nameplate Notes:
TEMP CONT HTR LDS H 115V 200W
ROT CW FACING ODE LEAD/PH SEQUENCE 1-2-3/1-2-3
INVERTER DUTY PER NEMA MG1 PART 31
ALTERNATE RATING FOR PWM CONTROL:1.0SF 40C AMBIENT
VAR TORQUE RANGE 0-60 HZ; CHP RANGE 60-63 HZ
MAXIMUM EXPOSED INTERNAL AND EXTERNAL SURFACE
TEMPERATURES DO NOT EXCEED 215C UNDER USUAL
SERVICE CONDITIONS AT 1.0SF
MAXIMUM SPACE HEATER SURFACE TEMPERATURE FOR
NORMAL OPERATION AT RATED CONDITIONS 172C
STAMP NP249A5499AP AS BELOW:
MODEL: 5KS513SAA199ZGP S/N: XXX
EX NA IIC T2D GC CSA.09.2216219
CLASS I, ZONE 2, AEX NA IIC T2D
CLASS I, DIV 2, GROUPS A, B, C, D T2D
-40 DEG C <= TAMB <= +40 DEG C

Model Number:5KS513SAA199ZGP
2P - ST EXTN - SPLIT LEAD
FOR DIRECT COUPLED LOAD ONLY
CW ROTATION FACING OPPOSITE DRIVE END
5700 CU IN - 3(3.00" NPT) WITH NON SELF TAPPING SCREWS
C/B GRD PLATE
100 0HM WINDING RTD LEADS TO AUX C/BOX ON F2 SIDE DE
115V TEMP CONT HTR LDS TO AUX BOX F2 SIDE ODE
SPACE HEATER CAUTION NAMEPLATE
BEARING RTD 100 OHM ON BOTH ENDS
NEMA TYPE GRD PAD
F1 MOUNTING
INSULATED BEARING AT DE AND ODE
PLASTIC THREADED PLUGS FOR ALL CONDUIT OPENINGS
TEFC SD O & G DHEERAJB 09/11/2014

Model Number:5KS513SAA199ZGP
Performance Characteristics
1st Winding 1st Connection
This motor is capable of two cold or one hot start with a maximum connected load inertia of 1269 Lb-Ft Sq (53.42 Kgmeter Sq)at 100% voltage, where the load torque varies with the square of the speed. Acceleration time with maximum
inertia and the above load type is 27 seconds. Safe stall time at 100% voltage is 59 seconds cold, 33 seconds hot. Rotor
inertia is 156.68 Lb-Ft Sq (6.6 Kg-meter Sq).

Model Number: 5KS513SAA199ZGP