Model Number:
Accessory Connection Diagrams
Performance Characteristics
Power Conversion
Data shown is for the current revision model #. Ensure your nameplate model # matches.
Model Number:5KS509AAG105A
Enclosure is Weather Protected One
Stamped Nameplate Notes:
NEMA ENCLOSURE WP-I, CSA ENCL DP
GE SELF DECLARED CLASS I DIV 2 MOTOR
MAX EXPOSED INTERNAL AND EXTERNAL SURFACE
TEMPERATURES UNDER USUAL SERVICE CONDITION
AT 1.00 S.F. DO NOT EXCEED 200 DEG C
VIBRATION LIMIT = 0.150 IN/SEC
TEMP CONT HTR LDS HE1-HE2 115V 200W
OFFSET CORE - DO NOT ASSEMBLE F2
MAXIMUM SPACE HEATER SURFACE
TEMPERATURE 160 DEG C
2 POLE, LS SHAFT EXTN
FORMED COIL
(2)GROUND BOLTS ON FRAME
TEMP CONTRL 115V HEATER LEADS TO ACC BOX
100 OHM WINDING RTD LEADS TO ACC BOX
SUGGESTED WINDING RTD SETTINGS
ALARM 165C TRIP 175C
PROVISION FOR BTDS BOTH ENDS
SUGGESTED BEARING RTD SETTINGS,IF PROVIDED
ALARM 115C TRIP 125C
2500 Cu. In. CBOX
PROVISION FOR JACK SCREWS
DP-WPI STOCK 09/25/16
ENGINEER: BAADKARD/BALASUBRAMANIANH
Page | 1
Model Number:5KS509AAG105A
Performance Characteristics
1st Winding 1st Connection
This motor is capable of two cold or one hot start with a maximum connected load inertia of 616 Lb-Ft Sq (25.93 Kg-meter
Sq)at 100% voltage, where the load torque varies with the square of the speed. Acceleration time with maximum inertia
and the above load type is 14 seconds. Safe stall time at 100% voltage is 31 seconds cold, 17 seconds hot. Rotor inertia
is 75.29 Lb-Ft Sq (3.17 Kg-meter Sq).
Page | 2