GE Industrial Motors M9806 Product Information Packet

Product Technical Information
June 23, 2020
Data shown is for the current revision model #. Ensure your nameplate model # matches.
Model Number:
5KS449SAA1049B
Catalog Number:
M9806
Instruction Manual:
GEI-56128
Connection Diagram:
GEM2034E-FIG2
Outline Drawing:
239C6800ACV
Accessory Connection Diagrams
Bearing Thermocouple:
None
Heater:
3027JE-1C
RTD:
235A3027XY
Thermistor:
None
Thermostat:
None
Winding Thermocouple:
None
Bearing RTD:
None
Table of Contents
Specification
01
Performance Characteristics
02
Outline Drawing
03
Connection Drawing(s)
04
Spare parts
05
Model Number:5KS449SAA1049B
June 23, 2020
Page | 1
Marks:
MODEL NUMBER:
5KS449SAA1049B
Estimated Weight:
2840 Lbs
Outline Drawing:
239C6800ACV
Time Rating:
CONT
Connection Diagram:
GEM2034E-FIG2
Enclosure:
TEFC
Instruction Book:
GEI-56128
Encl Construction:
X$D
Design Code:
49BD0125E
Ambient Max(°C):
40
Type:
KS
Alt Ambient Max(°C):
--
Frame:
449TS
Insulation Class:
F
Phases:
3
NEMA Design:
B
Poles:
2
Nominal Efficiency:
95.0 %
Output Power:
200HP 148KW
Guaranteed Efficiency:
94.5 %
RPM:
3580
3/4 Load Efficiency:
95.4 %
Voltage:
2300/4000
KVA Code:
G
Hertz:
60
Max KVAR:
36.8
Amps - FL:
43.1/24.9
Power Factor:
91.0
Service Factor:
1.15
Bearing - DE:
6314ZC3
Alt Service Factor:
--
Bearing - ODE:
6314ZC3
Enclosure is Totally Enclosed Fan-Cooled Stamped Nameplate Notes:
TEMP CONT HTR LDS HE1-HE2 115V 125W FOR DIRECT COUPLED LOAD ONLY ROT CCW FACING ODE LEAD/PH SEQ 3-2-1/1-2-3 GE SELF DECLARED CLASS I DIV2 GROUP A,B,C,D MOTOR MAX EXPOSED INTERNAL AND EXTERNAL SURFACE TEMPERATURES UNDER USUAL SERVICE CONDITIONS AT 1.00 S.F. DO NOT EXCEED 200 DEG C MAX SPACE HEATER SURFACE TEMPERATURE 160 DEG C
Additional Information:
2P - TS EXTN C/BOX 2500 CU IN - 2(4.00" NPT) OIL RESISTANT SLEEVING ON LEADS TWO SETS OF 100 OHM WINDING RTDS RTD LEADS EXIT TO ACCESSORY BOX W/ TERM BOARD 115V TSTAT CTRLD HTR LDS TO ACCESSORY BOX W/ TERM BOARD GROUND PAD F1 MOUNTING, OFFSET CORE - DO NOT ASSEMBLE F2 FORMED COIL SUGGESTED WINDING RTD SETTINGS ALARM 165C TRIP 175C
Model Number:5KS449SAA1049B
June 23, 2020
Page | 2
Performance Characteristics
1st Winding 1st Connection
Design: 49BD0125E
Marks:
LOAD %
125.0
115.0
100.0
75.0
50.0
25.0
0.0
% EFF
94.87
95.07
95.5
95.46
95.03
92.46
0.00
% PF
91.39
91.42
91.2
89.68
84.85
68.02
6.47
AMPS
31.03
28.48
24.72
18.86
13.35
8.56
5.92
TORQ(FL)#FT
293.17
TORQ(LR)%FL
169.89
TORQ(BD)%FL
308.8
AMPS(LR)
173.1
PF AT START
0.26
This motor is capable of two cold or one hot start with a maximum connected load inertia of 762 Lb-Ft Sq (32.08 Kg-meter Sq)at 100% voltage, where the load torque varies with the square of the speed. Acceleration time with maximum inertia and the above load type is 33 seconds. Safe stall time at 100% voltage is 77 seconds cold, 42 seconds hot. Rotor inertia is 51.17 Lb-Ft Sq (2.15 Kg-meter Sq).
Open Circuit A-C:
2.176
Short Circuit D-C:
0.026
Short Circuit A-C:
0.076 X/R Ratio:
9.765
Stator Slots:
48 Rotor Slots:
38