Product Technical Information
June 24, 2020
Data shown is for the current revision model #. Ensure your nameplate model # matches.
Accessory Connection Diagrams
Performance Characteristics
Model Number:5KS256XAA104D2
Enclosure is Totally Enclosed Fan-Cooled
Stamped Nameplate Notes:
IEEE-STD-841-2009
DE BRG 45BC03JP30 ODE BRG 45BC03JP30
STAMP NP249A5564P051 AS BELOW:
MODEL:5KS256XAA104D2 S/N: XXX
CSA CERTIFIED CSA09.2216219 FOR EX NA IIC 200 C GC
CL1ZONE2 AEXNAIIC 200 C; CL1DIV2 GRP ABCD 200 C
IN -25C <= AMB <= 40C, 1.0 SF ON SINE-WAVE PWR
SURF TEMP 300 C AT 1.15 SF ON SINE-WAVE PWR
OR 200 C VT OR 200 C CT OR 200 C CHP PWM CONTROL
ALTERNATE RATING FOR PWM CONTROL 1.0 SF 40 C AMB
VT 0-60 HZ, CT 15-60 HZ, CHP 60-90 HZ.
Model Number:5KS256XAA104D2
2P - T EXTN
STANDARD FLOOR MOUNT
C/BOX 137 CU IN-1.25 NPT
F1 CONDUIT BOX MOUNTING
PAINTED FRAME ID & SHAFT,
FAN COVER INSIDE & ODE E/S OUTSIDE
ROUTINE AND 5 POINT VIBRATION TESTS INCL IN C/BOX
INPRO SEAL BOTH ENDS
GROUND SCREW ON FRAME
SHAFT RUNOUT LIMIT .001" TIR
COPPER WASHER UNDER HEADS OF BEARING CAP BOLTS
APPLY TITE-SEAL (A50CD427A) ON BEARING CAP SCREWS, RABBETS,
AND PLUG THREADS
OIL RESISTANT SLEEVING ON LEADS