GE Industrial Motors E7342 Product Information Packet

Page 1
GE
Product Information Packet
November 7, 2016 Model Number:
5KS405ATE218A
Catalog Number:
E7342
Instruction Manual:
GEI-M1023
Connection Diagram:
GEM2034E-FIG8
Outline Drawing:
358B6203AD
Accessory Connection Diagrams
Bearing Thermocouple:
None
Heater:
None
RTD:
None
Thermistor:
None
Thermostat:
None
Winding Thermocouple:
None
Bearing RTD:
None
Table of Contents
Specification
01
Performance Characteristics
02
Outline Drawing
03
Connection Drawing(s)
04
Power Conversion
Data shown is for the current revision model #. Ensure your nameplate model # matches.
Page 2
Model Number:5KS405ATE218A
November 7, 2016
Marks:
MODEL NUMBER:
5KS405ATE218A
Estimated Weight:
1150 Lbs
Outline Drawing:
358B6203AD
Time Rating:
CONT
Connection Diagram:
GEM2034E-FIG8
Enclosure:
DP
Instruction Book:
GEI-M1023
Encl Construction:
OPEN
Design Code:
40AD1003A
Ambient Max(°C):
40
Type:
KS
Alt Ambient Max(°C):
--
Frame:
405TS
Insulation Class:
F
Phases:
3
NEMA Design:
A
Poles:
4
Nominal Efficiency:
95.4 %
Output Power:
125HP 92.5KW
Guaranteed Efficiency:
94.5
RPM:
1785
3/4 Load Efficiency:
96.2
Voltage:
460
KVA Code:
G
Hertz:
60
Max KVAR:
29.6
Amps - FL:
139
Power Factor:
86.5
Service Factor:
1.15
Bearing - DE:
6317
Alt Service Factor:
--
Bearing - ODE:
6313
Enclosure is Dripproof Stamped Nameplate Notes:
Additional Information:
4 POLE DP LRA AT 460 VOLTS: 968.3 AMPS NO. OF MOTOR LEADS: 6 CONDUIT BOX VOLUME (IN^3): 1240 CONDUIT BOX MTL: STAMPED STEEL GREASE TYPE: CHEVRON SRI-2 POLYUREA GREASE NOT USABLE AT 200 VOLTS 50 HZ DATA: 125 HP, 400V, 163 AMPS AT 1.0SF, 1480 RPM DMK, 06/04, DATA UPDATE 2/2005 INVERTER DUTY PER NEMA MG1 PART 31 FOR VARIABLE TORQUE LOADS
Page | 1
Page 3
Model Number:5KS405ATE218A
November 7, 2016
Performance Characteristics
1st Winding 1st Connection
Design: 40AD1003A
Marks:
LOAD %
125.0
115.0
100.0
75.0
50.0
25.0
0.0
% EFF
95.53
95.74
96.2
96.24
96.03
94.19
0.00
% PF
88.66
88.64
88.24
86.07
79.67
60
3.91
AMPS
172.65
158.54
137.82
105.93
76.45
51.76
39.25
TORQ(FL)#FT
368
TORQ(LR)%FL
194.9
TORQ(BD)%FL
282.55
AMPS(LR)
964.83
PF AT START
0.33
This motor is capable of two cold or one hot start with a maximum connected load inertia of 3104 Lb-Ft Sq (130.68 Kg­meter Sq)at 100% voltage, where the load torque varies with the square of the speed. Acceleration time with maximum inertia and the above load type is 33 seconds. Safe stall time at 100% voltage is 56 seconds cold, 40 seconds hot. Rotor inertia is 27.97 Lb-Ft Sq (1.18 Kg-meter Sq).
Open Circuit A-C:
0.995
Short Circuit D-C:
0.03
Short Circuit A-C:
0.037
X/R Ratio:
11.158
Stator Slots:
60
Rotor Slots:
50
Page | 2
Page 4
Model Number: 5KS405ATE218A
November 7, 2016
Marks:
Page 5
Model Number: 5KS405ATE218A
November 7, 2016
Marks:
Connection Diagram
GEM2034E-FIG8
Page | 4
Loading...