GE
Product Information Packet
November 7, 2016
Model Number:
Accessory Connection Diagrams
Performance Characteristics
Power Conversion
Data shown is for the current revision model #. Ensure your nameplate model # matches.

Model Number:5KS326ATE204A
Enclosure is Dripproof
Stamped Nameplate Notes:
4 POLE DRIP PROOF
CONDUIT BOX MATERIAL: STAMPED STEEL
CONDUIT BOX VOL: 253 CU IN
NO. OF MOTOR LEADS: 3
GREASE TYPE: CHEVRON SRI-2 POLYUREA
SOUND POWER DATA: 75.5
INVERTER DUTY PER NEMA MG1 PART 31
FOR VARIABLE TORQUE LOADS
Page | 1

Model Number:5KS326ATE204A
Performance Characteristics
1st Winding 1st Connection
This motor is capable of two cold or one hot start with a maximum connected load inertia of 1345 Lb-Ft Sq (56.62 Kgmeter Sq)at 100% voltage, where the load torque varies with the square of the speed. Acceleration time with maximum
inertia and the above load type is 33 seconds. Safe stall time at 100% voltage is 56 seconds cold, 45 seconds hot. Rotor
inertia is 8.37 Lb-Ft Sq (0.35 Kg-meter Sq).
Page | 2

Model Number: 5KS326ATE204A

Model Number: 5KS326ATE204A
Page | 4