GEIGER GJ5606k F03, GJ5610 F03, GJ5620 F03 Original Assembly And Operating Instructions

Page 1
1
www.geiger.de
EN
EN
DE
Original-Montage- und Betriebsanleitung
Notice originale de montage et d’utilisation
Instrucciones originales de instalación y funcionamiento
Istruzioni originali di installazione e funzionamento
EN
FR
ES
IT
Motor for Venetian blinds:
GEIGER GJ56.. AIR (GJ56.. F03)
for Venetian blinds
Page 2
2
Gerhard Geiger GmbH & Co. KG | 100W2500 0317V001en
EN
EN
1. General information
Dear customer, By purchasing a GEIGER motor you have decided on a quality product from GEIGER.
Thank you very much for your decision and the condence placed in us.
Before you put this drive into operation please observe the following safety instructions. It serves for the prevention of danger and for the avoidance of personal injury and damage to property.
The installation and operating instructions contain important information for the installer, the specialist electrician and the user. Please pass on these instructions if you transfer the product. These instructions should be kept by the user.
2. Guarantee
In the case of incorrect installation contrary to the installation and operating instructions and/
or constructional modication, the legal and contractual guarantee for property damage and
product liability lapses.
Index
1. General information ............................................................................2
2. Guarantee .............................................................................................2
3. Intended use ........................................................................................3
4. Safety instructions ..............................................................................3
5. Safety instructions for assembly .......................................................3
6. Assembly note .....................................................................................4
7. Installation instructions ......................................................................5
8. Information for the specialist electrician ..........................................7
9. Operating mode of the GEIGER GJ56.. AIR ......................................8
10. Connection to the Loxone Miniserver .............................................. 9
11. What to do if… ...................................................................................10
12. Declaration of conformity ................................................................. 11
13. Technical data ....................................................................................12
14. Maintenance .......................................................................................12
15. Notes on waste disposal ..................................................................12
Page 3
3
www.geiger.de
EN
EN
3. Intended use
The motors of the model range GJ56.. F03 with electronic end stop are designed exclusively for the operation of Venetian blinds.
The motors may not be used for the operation of roller grilles, garage doors, furniture and lifting tools.
GJ 56 xx x
Design options
Torque in Nm
For head rails at least 56 mm
GEIGER Venetian blinds motor
4. Safety instructions
I
ATTENTION: Important safety instructions. For personal safety, it is important to follow these instructions. Please keep these instructions for future reference.
f Do not allow children to play with stationary controls. Keep remote controls away
from children.
f The installation is to be checked regularly for defective balance, signs of wear or
damaged cables and springs, if relevant.
f Do observe the moving sun protection system and keep persons away until it has
closed completely.
f When operating the manual release with the sun protection system open, please be
cautious as it can fall down quickly if springs or tapes wear off or are broken.
f Do not operate the device if operations such as, for example, window cleaning are to
be carried out in the vicinity.
f Disconnect the automatic controlled device from the mains power supply if opera-
tions such as, for example, window cleaning are being carried out in the vicinity. f During operation observe the danger zone. f Do not use the installation if people or objects are in the danger zone. f Urgently shut down damaged installations until repair. f Unconditionally shut down the unit during maintenance and cleaning operations. f Pinching and shearing points are to be avoided and must be secured. f This appliance can be used by children aged 8 and above and persons whose
physical, sensorial or mental capacities are impaired, or who have no experience or
know-how if they have been supervised or been given instructions on the use of the
appliance and if they understand the possible resulting dangers. Children are not
permitted to play with the device. Cleaning and maintenance should not be carried
out by children. f The rated sound pressure level is less than 70 dB(A). f Disconnect the device from the mains power supply for maintenance and replace-
ment of parts.
If the motor is disconnected via a plug connection the operator must be able to
control - from any place to which it has access – that the plug is removed.
If this is not possible - due to design or installation - the disconnection from the
power supply must be ensured via locking in the disconnected position (e.g. isolator). f The motor tube can get very hot during prolonged use.
When working on the unit, do not touch the tube before it has cooled down.
5. Safety instructions for assembly
I
ATTENTION: Important safety instructions. Follow all installation instructions, as incorrect installation can lead to serious injuries.
f When mounting the motor without any mechanical protection of the driven parts and
of the tube which may become hot, the motor must be installed at a height of at least
2.5 m above the ground or of another level which provides access to the drive.
Page 4
4
Gerhard Geiger GmbH & Co. KG | 100W2500 0317V001en
EN
EN
f Before the motor is installed, all cables which are not needed are to be removed and
all equipment which is not needed for power-operated actuation is to be put out of
operation. f The actuating element of a manual release must be mounted at a height of less than
1.8 m.
f If the motor is controlled by a switch or pushbutton, the switch or pushbutton must
be mounted within eyeshot of the motor. The switch or pushbutton must not be
located in the vicinity of moving parts. The height of installation must be at least
1.5mabovetheoor.
f Permanently installed control devices must be attached visibly. f In case of devices extending horizontally, a horizontal distance of at least 0.4 m must
berespectedbetweenthefullyextendedpartandanyotherxedelement.
f The rated speed and the rated torque of the motor must be compatible with the
device. f The mounting accessories that are used must be designed in accordance with the
selected rated torque. f Good technical knowledge and good mechanical skills are necessary for the motor
installation. Incorrect installation can lead to serious injury.
Electricalworkmustbecarriedoutbyaqualiedelectricianinaccordancewiththe
regulations in force locally. f Only use connecting cables that are suitable with the environmental conditions and
which meet the construction requirements. (see accessories catalogue) f If the device is not equipped with a connecting cable and a plug, or other means for
disconnecting from the mains with a contact opening on each pole according to the
conditions of the overvoltage category III for full disconnection, a disconnecting
device of this type must be incorporated into the permanently installed electrical
installation according to the wiring rules. f Do not mount the connecting cables near hot surfaces. f A plug for the disconnection of the motor from the power supply must be accessible
after installation. f Damaged connecting cables must be replaced by GEIGER connecting cables of the
same type. f The device must be mounted as described in the installation instructions. Fixations
shall not be made with adhesives since they are regarded as unreliable.
6. Assembly note
When viewed from inside the room, the power supply connection of the GJ56.. F03 is located on the left side. The straps are wound on the winding rollers from the outside.
The GJ56.. F03 must be installed in alignment with the turning bars.
It is important that the GJ56.. F03 is installed centrally. Please make sure that the load is evenly distributed.
Inclined installation:
The inclined installation is permitted till 45° maximum to level.
Electric mains
Inside the room
Direction OPEN
Page 5
5
www.geiger.de
EN
EN
7. Installation instructions
I
Prior to installation please check to ensure there is no visible damage to the motor like cracks or open cables.
I
Beforexingpleasecheckthestrengthofthemasonryandofthe
surface.
Head rail opening at top:
Page 6
6
Gerhard Geiger GmbH & Co. KG | 100W2500 0317V001en
EN
EN
Head rail opening at bottom:
i
Page 7
7
www.geiger.de
EN
EN
8. Information for the specialist electrician
I
The GJ56.. AIR can be connected to the mains supply with either a 4-wire connection cable (Flat4 plug) or with a 5-wire connection cable (Flat5 plug).
H
Caution: Important installation instructions. Please follow all instructions since incorrect installation can lead to the destruction of the motor and the switching unit.
General
– The operations with the service clamps may be accomplished only by an electrical
specialist. – Motors with electronic limit stops can be connected in parallel. – In this case the maximum load of the switching unit must not be exceeded.
Connection with a 4-wired connecting cable
– When changing the running direction the switchover
must be effected through an off-position. – When changing the running direction the switchover
time must be at least 0.5 s. – With a three-phase network, please use the same
external conductor in order to control the UP and
DOWN directions. – PVC cables are not suitable for equipment used
outdoors or exposed to prolonged high levels of UV
radiation. These cables should not be used if they are
likely to touch metal parts that can heat up to tempera-
tures exceeding 70°C. – Connecting cables with plug connectors of the Hirschmann Company are tested and
approved with couplings of the Hirschmann Company.
Hirschmann plug connectors Function Wire colour
PE contact PE green/yellow
Pole 1 N blue
Pole 2 UP brown
Pole 3 DOWN black
Cable designation: 05RR-F 4G 0,75mm
2
AIR radio controlled
limit stop
blue
black
brown
green/yellow
PE NL1
L1
N
PE
Mains 230V / 50Hz
123
H
CAUTION / IMPORTANT NOTE
 The black wire of the connecting cable can be under
power.
 The black wire must be fully insulated for touch-safe
operations.
 The open end of the black wire must be insulated
with an insulated clamp or other insulated material.
Page 8
8
Gerhard Geiger GmbH & Co. KG | 100W2500 0317V001en
EN
EN
Connection with a 5-wired connecting cable
– When changing the running direction the switchover
must be effected through an off-position. – When changing the running direction the switchover
time must be at least 0.5 s. – With a three-phase network, please use the same
external conductor in order to control the UP and DOWN
directions. – PVC cables are not suitable for equipment used
outdoors or exposed to prolonged high levels of UV
radiation. These cables should not be used if they are
likely to touch metal parts that can heat up to temperatu-
res exceeding 70°C. – Connecting cables with plug connectors of the Hirsch-
mann Company are tested and approved with couplings
of the Hirschmann Company.
Hirschmann plug connectors Function Wire colour
PE contact PE green/yellow
Pole 1 DOWN black
Pole 2 UP grey
Pole 3 L brown
Pole 4 N blue
Cable designation: 05RR-F 5G 0,75mm
2
9. Operating mode of the GEIGER GJ56.. AIR
The motor can be operated in three ways. Individual control: the motor is operated with a handheld or wall transmitter. Alternatively, the
motor may be additionally operated with a locked control button. For this purpose, connect the motor with a 5-core connection cable according to the diagram. The adjustment of the end positions is only possible via a handheld or wall transmitter.
Smart Home control: the motor is connected, congured and operated with a Loxone Miniserver
or a Loxone Miniserver Go.
A subsequent change between individual control and Smart Home control is possible by repeated teaching in of the motor.
Please nd below the commissioning/ operating instructions concerning the individual control
with a Loxone Miniserver or Loxone Miniserver Go. .
AIR radio controlled
limit stop
blue
grey
brown
green/yellow
PE N
4321
L1
black
UP
DOWN
L1
N
PE
Mains 230V / 50Hz
Page 9
9
www.geiger.de
EN
EN
10. Connection to the Loxone Miniserver
Conditions
In order to integrate the GEIGER GJ56.. AIR in your Loxone system, a Miniserver Go or a Miniserver with Air Base Extension must be operational.
More information under: www.loxone.com/help/miniserver
CommissioninginLoxoneCong
Open Loxone Config and connect with your Miniserver. Then select the Air Base Exten­sion in the peripheral tree and activate the Air Monitor. Next, click „start search“ in the learning monitor. All Air devices that are in the learning mode are now listed.
Now connect the Venetian blind motor to a power source. To signal a restart, the motor twitches twice and scans the available radio channels until it finds a searching Air Base.
Now mark the GJ56.. AIR , enter a name and assign a room to it. Then, click „create device“.
The Venetian blind motor appears under the given designation in the tree. When it is clicked in the tree, it jerks twice.
Select the Venetian blind motor and drag & drop to a programming page.
“Save in Miniserver” transfers the changes made in the Config to the Miniserver.
The motor is now programmed and features the standard configuration as well as a visualiza­tion where the upper end position can be easily taught. For more information and documenta­tion please visit www.loxone.com/help/blindmotor-gj56-air
If the end positions have already been programmed with a handheld or wall transmitter they do not need to be taught again.
Page 10
10
Gerhard Geiger GmbH & Co. KG | 100W2500 0317V001en
EN
EN
11. What to do if…
Problem Solution
Motor does not run. Motor not plugged in.
Please check the plug connection.
Check connecting cable for possible damage.
Check the mains voltage and allow the cause of the voltage break down to be tested by a specialist electrician.
Instead of in the downwards direction, motor runs upwards.
End position order was not observed (set first the lower end position)
Motor only runs in one direction.
Motor in the end position. Run motor in the opposite direction. Readjust the end positions, if necessary.
After running several times, the motor breaks down and no longer responds.
The motor became too hot and has switched off. Try it again after a cooling time of about 15 min.
The blind is in the upper position, actuates the limit stop switch and can no longer be moved downwards.
The motor was installed upside down or the lower end position has been overrun and the lift tapes were wound up incorrectly. Allow free mobility of the limit stop switch. Reset the end stops.
The slats are positioned at different angles depending if the intermediate position is approached from the top or from below.
Reset the reference angle of the slats.
Page 11
11
www.geiger.de
EN
EN
12. Declaration of conformity
Gerhard Geiger GmbH & Co. KG Antriebstechnik Schleifmühle 6 D-74321 Bietigheim-Bissingen
100W1518 0117
EU Declaration of Conformity
Bietigheim-Bissingen, 02.01.2017 Dr. Marc Natusch (General Manager)
en
Product designation:
Venetian blinds motor, motor for rolling shutters, motor for awnings
Type designation:
GJ56.. GR45.. GU45.. GSI56..
Applied directives:
2006/42/EC 2014/30/EU 1999/5/EC 2011/65/EU
Applied standards:
DIN EN 60335-1 DIN EN 60335-2-97 DIN EN 62233 DIN EN 55014-1 DIN EN 55014-2 DIN EN 61000-3-2 DIN EN 61000-3-3 ETSI EN 300 220-2 ETSI EN 301 489-1 ETSI EN 301 489-3
Authorized representative for technical data:
Gerhard Geiger GmbH & Co. KG
Address:
Schleifmühle 6, D-74321 Bietigheim-Bissingen
Current declarations of conformity are available under www.geiger.de
Page 12
12
Gerhard Geiger GmbH & Co. KG | 100W2500 0317V001en
EN
EN
For further information and documentation please visit: www
.loxone.com/help/blindmotor-gj56-air
Gerhard Geiger GmbH & Co. KG
D-74321 Bietigheim-Bissingen
www.geiger.de
Loxone Electronics GmbH
A-4154 Kollerschlag www.loxone.com
13. Technical data
Technical data GJ56.. F03
GJ5606k F03 GJ5610 F03 GJ5620 F03
Voltage 230 V~/50 Hz
Current 0,40 A 0,60 A 0,85 A
Cos Phi (cosj) > 0,95
Inrush current (factor) x 1,2
Power 93 W 135 W 190 W
Torque 6 Nm 10 Nm 2 x 10 Nm
Speed 26 1/min
Protection class IP 54
Limit switch range 200 r.p.m..
Operating mode S2 4 min. S2 4 min. S2 4 min.
Length 319,5 mm 329,5 mm 356,7 mm
Diameter 55 mm
Weight approx. 1,50 kg approx. 1,70 kg approx. 2,20 kg
Ambient temperature / humidity
Operation: T = -10°C .. on request / H max. 90% Storage : T = -15°C .. +70°C / dry and non-condensing place
Subject to technical modifications
DE
V
geprüfte Sicherheit
14. Maintenance
The drive is maintenance-free.
15. Notes on waste disposal
Recycling of packaging materials
In the interest of environmental protection, please contact your local government’s recycling or solid waste management department to learn more about the services it provides.
Waste disposal of electric and electronic equipment
Electrical and electronic equipment must be collected and disposed of separately in accordance with EU regulations.
Loading...