GE - General Electric VH Series, VCL Series Data Sheet

GE
Critical Power
New
High Reliability & Efficiency
Single phase VH & VCL Series
imagination at work
High Reliability & Efficiency
Single phase VH & VCL Series
New
VH Series
700/1000/1500/2000 VA
Uninterruptible Power Supply (UPS)
GE’s VH Series UPS is a true VFI (Voltage and Frequency Independent) on line, double conversion range providing the highest and most secure level of power protection for all business-critical applications. With a tower and/or rackmount
design, the UPS adapts to adjusting network congurations
as facility load requirements change. Delivering 0.9 output power factor, an MTBF of 730,000 hours and provided with a three year warranty as standard on both UPS and battery, the user can be assured of a high performance, high power and highly reliable level of power protection.
True Double Conversion VFI (Voltage and
Unique Superior Battery Management
Hot swappable batteries
Rack and/or tower assembly
3 year warranty
High output power factor
Features & benets
Voltage and Frequency Independent (VFI) double
conversion, true on line technology
Even when the quality of the utility is poor, the UPS will deliver a constant voltage and frequency to the critical load. When the utility fails, the UPS transfers seamlessly to battery.
0.9 output power factor
Delivers more actual power to the load; highly suited for today’s power-dense servers and data centers.
Easy, fast user battery replacement
Hot swappable battery replacement. UPS may remain live, supporting the critical load, during the battery replacement period (<1 minute).
Tower and/or rackmount, small footprint
2U high across range to maximise rack space. All assembly parts for tower and rack assembly delivered in packing box.
Failsafe bypass
The fully isolated bypass, designed with a fast and reliable static switch, provides a seamless transition from UPS to bypass if multiple fault conditions (e.g. overtemperature or overload) occur.
Superior Battery Management
Unique 7-level battery management providing protection to the battery and extending the battery life.
Matching battery cabinets
Longer battery life available with the addition of extra battery cabinet(s).
Unique high peak load handling
The VH Series standard design allows the user to support a laser printer type load on the UPS without risking UPS or battery performance.
New
VCL Series
800/1100/2000/3000 VA
Uninterruptible Power Supply (UPS)
GE’s VCL Series Uninterruptible Power Supply (UPS) is designed with Automatic Voltage Regulation (AVR) including buck/boost technology, suppressing or boosting the voltage from the utility to provide conditioned power to the attached load. Buck/boost minimizes the need to transfer to battery, maximizing the battery life. When the grid power fails, the battery steps in to continue the supply and allow for enough
time to nish the current process before gracefully initiating
an automatic shutdown of the load until the utility power returns.
Features & benets
High eciency
The VCL Series operates as standard at a >95% reducing both energy and operational costs at site.
Hot swappable, user replaceable batteries
Batteries can be replaced quickly, safely and simply while the load remains connected, eliminating the need to power
o a critical load for standard maintenance and with zero
risk to the user.
Wide input voltage window
Minimises battery use and extends the life of the battery. Allows the VCL Series to run undisturbed, when other UPS may have already switched to battery then shut down.
Voltage Independent technology with
Automatic Voltage Regulation (AVR)
Hot swappable batteries
High efficiency
Rack and/or tower assembly
2U rack height
Graphic display
Multiple outlets
For all ratings; several pieces of equipment can be connected to the VCL Series without adding PDUs or extension strips.
Free automatic shutdown software
GE’s Automatic Shutdown Software is delivered with each UPS, allowing for a graceful, controlled shutdown of the connected load in the event of a lengthy mains failure.
Data protection software and connectivity solutions
GE’s UPS come standard with two software packages: UPSMAN and RCCMD. UPSMAN is a complete protection software providing a graphical interface for monitoring the UPS. It communicates with the
UPS via the standard RS232 / USB interfaces or via an optional SNMP plug-in card. In order to avoid data corruption it enables the computer on which it is installed to shutdown gracefully if the UPS is not able to supply the required power. UPSMAN can also act as a “master computer” which can send remote shutdown commands to multiple remote computers/servers in case of a UPS failure. These remote computers/servers, centrally controlled by a computer running UPSMAN, need to run on their turn the light software package named RCCMD.
Small
networks
UPSMAN – description
Data Protection Software
Supports RS232 , USB & SNMP communication
Free software license
Written in native language
Supports most popular OS, including virtualization
As an alternative for the solution above, with a “master computer” controlling multiple remote computers in a network, the UPS can be equipped with an SNMP card. This card sends the required remote shutdown commands directly to the remote network computers, which again all run the software RCCMD.
RCCMD – description
Light background protection software
Native solution for more than 35 OS
React on shutdown commands
Electronic
point of sale
(EPOS)
GE’s iUPSGuard is a remote monitoring solution for UPS,
providing status monitoring and alarm notication that
supports all GE UPS product lines, anytime, anywhere. iUPSGuard provides current and detailed information about
UPS operation, including its conguration, internal alarms,
automatic reporting and operating conditions over the web.
Highly secure and efficient data transmission
SSL encrypted unidirectional communication
Firewall friendly – no changes required to firewall
settings or proxy servers providing easy deployment and addressing compliance objectives
Supports various communications including IP and GPRS
PCs
Servers
CCTV
Servers
VCL Series
Telecom
Medical
VH Series
Process
Control
VH Series - Technical specications
Model
Rating VA/W
Part number 25510 25511 25512 25513
AC input voltage window 60 - 140 Vac Input frequency range 45 - 66 Hz AC output voltage 100 / 110 / 115 / 120 / 127 Vac (selectable) AC output voltage tolerance ± 2% Output frequency auto-selectable or 50/60 Hz (front selectable) Output frequency stability ± 0.15% Output wave form sine wave Output power factor 0.9 Crest factor 6:1 Output THD < 2% (typical 1%) with linear load Battery type 12V, sealed lead acid, maintenance free Number x capacity of battery 3 x 7Ah 3 x 9Ah 6 x 7Ah 6 x 9Ah Runtime at typical load (75%), minutes 12 12 11 12 Battery recharge time 3 hours for 90% capacity, std. battery Input connection IEC C14 IEC C14 IEC C20 IEC C20 Output connection 4x NEMA 5-20R 6x NEMA 5-20R 6x NEMA 5-20R 6x NEMA 5-20R & 1x L5-20R Weight 35 Lbs (16 kg) 37 Lbs (17 kg) 64 Lbs (29 kg) 71 Lbs (32 kg) Dimensions (hxwxd) 3.4 x 17.2 x 18.5 inch (87 x 438 x 470 mm) 3.4 x 17.2 x 21.3 inch (87 x 438 x 540 mm) Communication port USB / RJ11 Safety ETL tested to UL1778 Standards EMC EN 62040-2 Ambient temperature 32 °F to 104 °F (0 °C to 40 °C) Maximum relative humidity 95% (non-condensing)
VH700 UL
700/630
VH1000 UL
1000/900
VH1500 UL
1500/1350
VH2000 UL
1920/1740
Option list for VH UPS Part number
Battery Pack UL 36V 14Ah (VH 700/1000) 25268
Battery Pack UL 72V 14Ah (VH 1500/2000) 25269 SNMP / Web Adapter Card 1-ph (for VH) 1024747 RS232, USB & Relay Card 18802 iUPSGuard 1 yr license 26104
Rear panel VH Series
1000VA UPS
Fans
DC connector for battery extension
Specications subject to change without prior notice
Input circuit breakerRJ11 communication port
Input socketUSB communication port
Appliance outlets
VCL Series - Technical specications
Model
Rating VA/W
VCL800 UL
800/640
VCL1100 UL
1100/880
VCL2000 UL
1920/1600
VCL3000 UL
2880/2400
Part number 25926 25927 25928 25929
AC input voltage 120 Vac AC input voltage, window 90 - 150 Vac Frequency 50 / 60 Hz ± 5 Hz (auto-sensing) Power factor 0.8 AC output voltage 120 Vac AC output voltage tolerance (until low battery) ± 5% Output frequency 50 / 60 Hz ± 1% (auto-sensing) Output frequency stability < ± 0.1 Hz (battery operation) Output wave form sine wave Crest factor 3:1 Output THD < 8% with linear load Input connection NEMA 5-15P NEMA 5-20P NEMA L5-30P Output connection 6 x NEMA 5-15R 6 x NEMA 5-20R Runtime at typical load (60%), minutes 8 8 9 9 Weight 30 Lbs (13.5 kg) 33 Lbs (15 kg) 55 Lbs (25 kg) 73 Lbs (33 kg) Dimensions (hxwxd) 3.5x17.3x16.0 inch (88x440x405 mm) 3.5x17.3x24.4 inch (88x440x620 mm) Safety ETL tested to UL1778 Standards Ambient temperature 32 °F to 104 °F (0 °C to 40 °C) Sound at 1 meter <55 dB(A), load and temperature dependent Maximum relative humidity 95% (non-condensing)
Option list for VCL UPS Part number
Specications subject to change without prior notice
SNMP / Web Adapter Card 1-ph (for VCL) 1024746 iUPSGuard 1 yr license 26104
Front panels
VH Series VCL Series
Rear panel VCL Series
USB communication port Optional SNMP communication card
test
VH Series - Uninterruptible Power Supply
Input thermal circuit breaker
Input cord
Output thermal circuit breakers
Digital Energy
%
100
75
50
25
Phone/fax protectionRS232 communication port
>
UPS status indicators
Keypads
Load LED bar
Runtime capacity
test
VCL Series - Uninterruptible Power Supply
3000VA UPS
Appliance outlets
Digital Energy
%
100
75
50
25
>
imagination at work
GEA-D 1057 US UL listed product version Rev. 12/15 1027712 / 151209 *Trademark of General Electric Company. Copyright 2015 General Electric Company. All Rights Reserved.
GE reserves the right to make changes to specications of products
described at any time without notice and without obligation to notify any person of such changes.
GE
Critical Power