GE - General Electric Reduced Voltage Starters Solid State Catalog Page

Page 1
Reduced Voltage Starters
Solid State
ASTAT XT Soft Starter
Digital Soft Starters for 3ph Standard Induction Motors
GE’s new solid state ASTAT XT Soft Starter features microprocessor control digital technology. Setup and adjustment is performed through a six-button keypad and parameters or messages are displayed through a user-friendly LCD multi-language interface with two rows, sixteen alphanumeric characters each. The design includes isolated I/O and a high level of protection in circuits to minimize the disturbance effects while working in the harshest industrial environment.
ASTAT XT Soft Starter offers reliable performance and smooth acceleration for a variety of standard AC motors, up to 1400A and up to 690V, reducing mechanical shock to the driving system, resulting in extended component and motor life.
ASTAT XT Soft Starter offers many traditional features such as a motor overload function, adjustable ramps, current limit , kick start, as well as other high end features like inside-delta operation, torque control, pump control and a reliable motor and unit set of protections.
Section 2
Features
—Ratings up to 1400 Amps and up to 690 VAC —Friendly multi-language interface with two rows, sixteen
characters each —Built-in with three extra power terminals for external bypass —In-line or inside-delta operation modes —Torque control and pump control advanced features —Motor protection according IEC 10,20 and NEMA 10, 20, 30,
even if ASTAT XT Soft Starter is in bypass —Built in RS485 port communications, and ModBus protocol
as standard —Profibus-DP and DeviceNet optional interfaces for
communications
Standards
CE: Full Range cUL, UL: For units up to 820A. “U” type
2-2
Control Catalog
Rev. 8/15
Prices and data subject to change without notice
Page 2
Reduced Voltage Starters
Solid State
ASTAT XT Soft Starter
Product Number Configuration
QT 1 0008 U21MS
Section 2
ASTAT XT Soft Mains Voltage Current Ratings UL Certification1Control Voltage2Control Inputs Starter Range
1 = 230-500V U = UL 1 = 110VAC 1 = 90-230VAC M = Standard Options 2 = 460-600V N = non-UL 2 = 230VAC 2 = 24VDC P = Profibus 3 = 690V D = DeviceNet
Notes:
cUL Certification
1
ASTAT XT Soft Starter up to 600V, and up to 170A (Product Numbers up to QT10170_ or QT2) are always cUL certified. Option “N” not available Units QT2, from QT20008_, up to QT20820_ are always cUL certified. Option “N” not available. Units QT1, or QT2 from QTx0950_ up to QTx1400 are not UL certified. Option “U” not available. Units QT3__, rated to 690V, are not UL certified. Option “U” not available
Control and Inputs Voltage
2
ASTAT XT Soft Starter standard Control Voltage is option 2, Voltage 230VAC, +10%, -15%
3
ASTAT XT Soft Starter standard configuration for Inputs is option 1, Voltage 90-230VAC, +10%, -15%
All ASTAT XT Soft Starter models rated 950A and up must
be operated with a bypass contactor.
3
Communications Future
Rev. 8/15
Prices and data subject to change without notice
Control Catalog
2-3
Page 3
Reduced Voltage Starters - Solid State
educed Voltage Starters
R
S
Solid State
ASTAT XT Soft Starter
and IEC Ratings. Recommended Unit Type and Motor Ratings.
NEMA
Light Duty Normal Duty Heavy Duty
NEMA 10 NEMA 20 NEMA 30
Current Current Current
Rating 230V 460V 575V Rating 230V 460V 575V Rating 230V 460V 575V
A HP HP HP A HP HP HP A HP HP HP Number
Line Voltage 82--- --- 82--- --- 82--- --- QT10008U11MS 230VAC 17 5 --- --- 17 5 --- --- 12 3 --- --- QT10017U11MS
Line
Voltage 8 --- 55 8--- 55 8--- 55 QT20008U11MS
460 - 600VAC 17 --- 10 15 17 --- 10 15 12 --- 7.5 10 QT20017U11MS
Line
Voltage --- --- --- --- 8 --- --- 5.5 8 --- --- 5.5 QT30008N11MS
690V --- --- --- --- 17 --- --- 15 12 --- --- 7.5 QT30017N11MS
For 230V Control Voltage - Change the "1" in digit place 9 to "2". Example QT10031U11MS becomes QT10031U21MS. No Price Adder. For 24V DC Digital I/O - Change the "1" in digit 10 to "2". Example QT20072U11MS becomes QT20072U12MS. No Price Adder. For Profibus DP Communications - Change the "M" in digit 11 to "P". Example QT10390U11MS becomes QT10390U11PS. Price adder is $850.00 For DeviceNet Communications - Change the "M" in digit 11 to "D". Example QT20085U11MS becomes QT20085U11DS. Price adder is $950.00
All ASTAT XT Soft Starter models rated 950A and up must be operated with a bypass contactor.
34 10 --- --- 31 10 --- --- 31 10 --- --- QT10031U11MS 54 20 --- --- 44 15 --- --- 44 15 --- --- QT10044U11MS 65
20 --- --- 58 20 --- --- 55 20 --- --- QT10058U11MS
72 25 --- --- 72 25 --- --- 66 --- --- QT10072U11MS
40 --- --- 85 30 --- --- 80 30 --- --- QT10085U11MS
104 130
50 --- --- 105 40 --- --- 99 40 --- --- QT10105U11MS
156 60 --- --- 145 50 --- --- 130 50 --- --- QT10145U11MS
60 --- --- 170 60 --- --- 134 50 --- --- QT10170U11MS
170 262
100 --- --- 210 75 --- --- 203 75 --- --- QT10210U11MS
387 150 --- --- 310 100 --- --- 310 100 --- --- QT10310U11MS
150 --- --- 390 150 --- --- 361 150 --- --- QT10390U11MS
414 480
200 --- --- 460 150 --- --- 432 --- --- QT10460U11MS 610 250 --- --- 580 200 --- --- 552 200 --- --- QT10580U11MS 820 ---
--- 25 30 31 --- 20 25 31 --- 20 25 QT20031U11MS
34 54
--- 40 50 44 --- 30 40 44 --- 30 40 QT20044U11MS
65 --- 50 60 58 --- 40 50 55 --- 40 50 QT20058U11MS
--- 50 60 72 --- 50 60 66 --- 50 60 QT20072U11MS
72
104
--- 75 100 85 --- 60 75 80 --- 60 75 QT20085U11MS
130 --- 100 125 105 --- 75 100 99 --- 75 100 QT20105U11MS
--- 125 150 145 --- 100 150 130 --- 100 125 QT20145U11MS
156 170
--- 125 150 170 --- 125 150 134 --- QT20170U11MS
262 --- 200 250 210 --- 150 200 203 --- 150 200 QT20210U11MS
--- 300 400 310 --- 250 300 310 --- 250 300 QT20310U11MS
387 414
--- 350 390 --- 300 400 361 --- 300 QT20390U11MS
480 --- 400 500 460 --- 350 432 --- 350 400 QT20460U11MS
--- 500 580 --- 400 552 --- 400 500 QT20580U11MS
610 820
--- 820 --- 500 500 690 --- 500 QT20820U11MS
--- --- --- 31 --- --- 22 31 --- --- 22 QT30031N11MS
---
---
--- --- --- 44 --- --- 37 44 --- --- 37 QT30044N11MS
--- --- --- --- 58 --- --- 55 55 --- --- 45 QT30058N11MS
--- --- --- 72 --- --- 55 66 --- --- 55 QT30072N11MS
---
---
--- --- --- 85 --- --- 75 80 --- --- 75 QT30085N11MS
--- --- --- --- 105 --- --- 90 99 --- --- 90 QT30105N11MS
--- --- --- 145 --- --- 132 130 --- --- 90 QT30145N11MS
---
---
--- --- --- 170 --- --- 160 134 --- --- 132 QT30170N11MS
--- --- --- --- 210 --- --- 200 203 --- --- 200 QT30210N11MS
--- --- --- 310 --- --- 250 310 --- --- 250 QT30310N11MS
---
---
--- --- --- 390 --- --- 355 344 --- --- 315 QT30390N11MS
--- --- --- --- 460 --- --- 400 432 --- --- 400 QT30460N11MS
--- --- --- 580 --- --- 560 488 --- --- 400 QT30580N11MS
---
---
--- --- --- 650 --- --- 630 552 --- --- 560 QT30650N11MS
--- --- --- --- 950 --- --- 900 950 --- --- 900 QT30950N11MS
--- --- --- 1100 --- --- 1000 1076 --- --- 1000 QT31100N11MS
---
---
--- --- --- 1400 --- --- --- 1400 --- --- --- QT31400N11MS
--- 820 250 --- --- 690 250 --- --- QT10820U11MS
Normal Duty Heavy Duty
IEC Class 10 IEC Class 20
A 690V
KW A 690V KW Number
Product List Price
Product List Price
ection 2
2-4
Contr
ol Catalog
ev. 8/15
R
and data subject to
Prices change without notice
Page 4
Reduced Voltage Starters
Solid State
ASTAT XT Soft Starter
Technical Specifications
Section 2
Ratings
Main Voltage 3Ph AC supply - 230 to 500VAC +10%, -15% for QT1xxx units
Starter Current Rating for 3Ph AC motors - From 8A up to 1400A.
Motor Current Rating 3 phase Induction motors - Motor rated current
Control Voltage 1ph AC supply - 230VAC, +10, -15%, 50/60Hz, or
Frequency Range 50/60Hz systems - Wide from 45Hz to 65Hz.
460 to 600VAC +10%, -15% for QT2xxx units
690VAC +10%, -15% for QT3xxx units
from 50% to 100% of starter current
110VAC, +10, -15%, 50/60Hz (optional)
Auto-tracking frequency range
Control Specifications
Control System Digital control with microcontroller.
Operation Mode In-Line (three wires) or Inside-Delta (six wires) of the motor
Run Operation Soft Start and Soft Stop by multiple choices,
Operator Interface By LCD display, keypad and indication LEDs
Initial Voltage 10-50% Un. Up to 80% with expanded settings function
Starting Current 100-400% In. Can be extended up to 500%,
Acceleration Ramp time 1-30 sec. Can be extended up to 90sec,
Deceleration Ramp time 1-30 sec. Can be extended up to 90sec,
Current Limitation 100-400% of motor rated current .
Bypass By external contactor while motor is full protected by ASTAT XT Soft Starter.
Monitoring Motor Current, Line Voltage, motor thermistor
Starting ramp, with progressive increase in voltage
including torque control both at Start or Stop phases
Display: LCD with two rows, 16 characters each
Type: Multi-language, Dip Switch selectable for English,
Keys: Six keys, Mode, Reset , Set, Select and Up / Down
LEDs: ON, Start , Run, Soft Stop, Stop, Save / Slow Speed,
Can be extended up to 500% by using extended settings
and current limitation
Italian, Spanish and German
Dual Set / Reverse and Fault
by using extended settings
by using extended settings
by using extended settings
resistance, Test & Maintenance and Statistics
Environmental Conditions
Operating Temperature -10 up to 50ºC, derating from 40ºC
Storage Temperature -20ºC up to 70ºC
Maximum Altitude Up to 1000 mts. Ask your dealer for installation at higher altitude
Humidity 95% at 50ºC or 98% at 45ºC
Protection Degree IP20 for units up to 72A, IP00 for units from 85A up to 1400A
Pollution Degree Class 3
Standards
Global Standards CE for the full range. UL , cUL for specified units up to 820A
EMC Emissions EN 55011: CISPR 11 Class A
Immunity EN 55082-2: ESD 8KV air, IEC 801-2;
Safety EN 600947-1: Related to safety requirements. UL508C
Electric RF field 10 V/m, 20-1000Mhz, IEC 801-3
Fast transients 2KV, IEC 801-4
Additional emergency safe stop functionality may be
required for your application.
Rev. 8/15
Prices and data subject to change without notice
Control Catalog
2-5
Page 5
Reduced Voltage Starters
IEC Class 10
Sec.
Multiples of motor FLA Rating In
1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0
10000
1000
100
10
1
COLD
HOT
IEC Class 20
Sec.
Multiples of motor FLA Rating In
1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0
10000
1000
100
10
1
COLD
HOT
NEMA 10
Sec.
Multiples of motor FLA Rating In
1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0
10000
1000
100
10
1
COLD
HOT
NEMA 20
Sec.
Multiples of motor FLA Rating In
1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0
10000
1000
100
10
1
COLD
HOT
NEMA 30
Sec.
Multiples of motor FLA Rating In
1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0
10000
1000
100
10
1
COLD
HOT
Section 2
Solid State
ASTAT XT Soft Starter
Technical Specifications
Overload Protections, Thermal Characteristics
The ASTAT XT Soft Starter allows motor protection according IEC Class 10 or Class 20 and NEMA 10, 20 or 30, user free selectable by ASTAT internal dedicated parameter.
Maximum number starting / hour
Starting 2 24 12 8 current I/In
1
In= rated current of ASTAT XT Soft Starter in the specified class IEC/NEMA.
1
Ramp time
10s 20s 30s
3 16 85 4 12 64
2-8
Control Catalog
Rev. 8/15
Prices and data subject to change without notice
Loading...