Transformers
Section 14
Open Core and Coil Transformers
Machine Tool Applications
Single-Phase
60 Hz Terminal Board Connection
Input Voltage Output Voltage KVA Frame Size 95% Sec. Volt Diagram No.
220 x 440, 230 x 460, 240 x 480 Volts 110, 115, 120 Volts 0.05 6100 193 1 9T58K0042
220 x 440, 230 x 460, 240 x 480 Volts 110, 115, 120 Volts 0.075 6125 303 1 9T58K0043
220 x 440, 230 x 460, 240 x 480 Volts 110, 115, 120 Volts 0.1 8100 396 1 9T58K0044
220 x 440, 230 x 460, 240 x 480 Volts 110, 115, 120 Volts 0.15 8150 724 1 9T58K0045
220 x 440, 230 x 460, 240 x 480 Volts 110, 115, 120 Volts 0.2 8175 821 1 9T58K0046
220 x 440, 230 x 460, 240 x 480 Volts 110, 115, 120 Volts 0.25 8200 1034 1 9T58K0047
220 x 440, 230 x 460, 240 x 480 Volts 110, 115, 120 Volts 0.3 8250 1037 1 9T58K0048
220 x 440, 230 x 460, 240 x 480 Volts 110, 115, 120 Volts 0.375 8250 1441 1 9T58K0049
220 x 440, 230 x 460, 240 x 480 Volts 110, 115, 120 Volts 0.5 10225 2027 1 9T58K0050
220 x 440, 230 x 460, 240 x 480 Volts 110, 115, 120 Volts 0.75 12225 3092 1 9T58K0051
220 x 440, 230 x 460, 240 x 480 Volts 110, 115, 120 Volts 1 12300 4494 1 9T58K0052
220 x 440, 230 x 460, 240 x 480 Volts 110, 115, 120 Volts 1.5 14225 5156 1 9T58K0053
220 x 440, 230 x 460, 240 x 480 Volts 110, 115, 120 Volts 2 14300 9193 1 9T58K0054
220 x 440, 230 x 460, 240 x 480 Volts 110, 115, 120 Volts 3 14475 14513 1 9T58K0055
Inrush VA @ .20 PF, Wiring Product
50/60 Hz Terminal Board Connection
Input Voltage Output Voltage KVA Frame Size 95% Sec. Volt Diagram No.
230/460/575 Volts 115/95 Volts 0.05 6100 196 2 9T58K0062
230/460/575 Volts 115/95 Volts 0.075 8100 278 2 9T58K0063
230/460/575 Volts 115/95 Volts 0.1 8150 445 2 9T58K0064
230/460/575 Volts 115/95 Volts 0.15 8200 663 2 9T58K0065
230/460/575 Volts 115/95 Volts 0.2 8200 864 2 9T58K0066
230/460/575 Volts 115/95 Volts 0.25 8250 1137 2 9T58K0067
230/460/575 Volts 115/95 Volts 0.3 10225 1412 2 9T58K0068
230/460/575 Volts 115/95 Volts 0.375 10225 1670 2 9T58K0069
230/460/575 Volts 115/95 Volts 0.5 10225 1822 2 9T58K0070
230/460/575 Volts 115/95 Volts 0.75 12300 3524 2 9T58K0071
230/460/575 Volts 115/95 Volts 1 14225 4392 2 9T58K0072
230/460/575 Volts 115/95 Volts 1.5 14300 6753 2 9T58K0073
230/460/575 Volts 115/95 Volts 2 14475 11563 2 9T58K0074
208/277/380 Volts 115/95 Volts 0.05 6150 217 3 9T58K0082
208/277/380 Volts 115/95 Volts 0.075 8100 322 3 9T58K0083
208/277/380 Volts 115/95 Volts 0.1 8150 464 3 9T58K0084
208/277/380 Volts 115/95 Volts 0.15 8200 761 3 9T58K0085
208/277/380 Volts 115/95 Volts 0.2 8200 837 3 9T58K0086
208/277/380 Volts 115/95 Volts 0.25 8250 1198 3 9T58K0087
208/277/380 Volts 115/95 Volts 0.3 10225 1409 3 9T58K0088
208/277/380 Volts 115/95 Volts 0.375 10225 1674 3 9T58K0089
208/277/380 Volts 115/95 Volts 0.5 10225 1821 3 9T58K0090
208/277/380 Volts 115/95 Volts 0.75 12300 3771 3 9T58K0091
208/277/380 Volts 115/95 Volts 1 14225 4234 3 9T58K0092
208/277/380 Volts 115/95 Volts 1.5 14300 7091 3 9T58K0093
208/277/380 Volts 115/95 Volts 2 14475 11729 3 9T58K0094
1
See page 14-6 for wiring diagrams.
Inrush VA @ .20 PF, Wiring Product
1
1
Number
Number
Factory- or Field-Installed Options
Secondary Fusing—Factory- or field-installed secondary fuse
clips are available. They are restricted to units with terminal strips
and a single secondary voltage or secondary with one tap.
Dual Primary and Secondary Fusing—Factory- or field-installed
dual primary and secondary fusing is available on all units, including leads out and multiple secondary voltages.
Leads Out—Terminal strip is replaced by rugged primary and
secondar
14-2
y leads emanating from the top of the encapsulated coil.