GE - General Electric Modular Metering Meter Mod III Catalog Page

Meter Mod III
Page Updated 10 / 2015
Meter Stack Modules Single-Phase Plus Accessories Product Features
—UL listed —800 amp, 4-wire cross bus (aluminum), except where noted below. —Ring-type and Ringless Sockets —Front Accessible Field Phase Balancing by Meter Module —(1) 14-4 Equipment Ground per Socket, Factory Installed
Section 2Modular Metering
TMP8512R TMPR8220R
Ring Type Socket
Product Socket Amps No. of Sockets Number
125A 2 TMP8212R 125A 3 TMP8312R 125A 4 TMP8412R 125A 5 TMP8512R 125A 6 TMP8612R 200A 2 TMP8220R 200A 3 TMP8320R 200A 4 TMP8420R 200A 5 TMP8520R 200A 5 TMP8520RBUS
4 4 4 4 4
4 4
One snap-type, aluminum sealing ring (TSR5) per socket included.
Ringless Type Socket (Includes 5th Jaw Standard)
Product
Socket Amps No. of Sockets Number
125A 2 TMPR8212R 125A 3 TMPR8312R 125A 4 TMPR8412R 125A 5 TMPR8512R 125A 6 TMPR8612R 200A 2 TMPR8220R 200A 3 TMPR8320R 200A 4 TMPR8420R 200A 5 TMPR8520R 200A 5 TMPR8520RBUS 200A 5 TMPR8520RHB 200A 5 TMPR8520RHBBUS
1
4,5 4,5 4,5 4,5 4,5 4,5 4,5 4,5 4,5
2
Product Features
—UL listed —1200 amp, 4-wire cross bus (aluminum) —Ring-type and Ringless Sockets —Front Accessible Field Phase Balancing by Meter Module —(1) 14-4 Equipment Ground per Socket, Factory Installed
Ring-Type Socket
Product
Socket Amps No. of Sockets Number
125A 2 TMP12212R 125A 3 TMP12312R 125A 4 TMP12412R 125A 5 TMP12512R 125A 6 TMP12612R 200A 2 TMP12220R 200A 3 TMP12320R 200A 4 TMP12420R 200A 5 TMP12520R 200A 5 TMP12520RBUS
Ringless Type Socket (Includes 5th Jaw Standard)
Product Socket Amps No. of Sockets Number
125A 2 TMPR12212R 125A 3 TMPR12312R 125A 4 TMPR12412R 125A 5 TMPR12512R 125A 6 TMPR12612R 125A 2 TMPR12212RHB 125A 3 TMPR12312RHB 125A 4 TMPR12412RHB 125A 5 TMPR12512RHB 125A 6 TMPR12612RHB 200A 2 TMPR12220R 200A 3 TMPR12320R 200A 4 TMPR12420R 200A 5 TMPR12520R 200A 5 TMPR12520RHB 200A 5 TMPR12520RBUS 200A 2 TMPR12220RHB 200A 3 TMPR12320RHB 200A 4 TMPR12420RHB
4,5
4
1
4 4 4
4 4
Ring Type Socket Factory Phase Balanced (w/Copper Bus)
Product Socket Amps No. of Sockets Number
125A 2 TMP8212RAB 125A 2 TMP8212RAC 125A 2 TMP8212RBC 125A 3 TMP8312RAB 125A 3 TMP8312RAC 125A 3 TMP8312RBC 125A 4 TMP8412RAB 125A 4 TMP8412RAC 125A 4 TMP8412RBC
Tenant Main Circuit Breakers 10,000 AIC
Wire Size Product
Socket Amps Ampere Rating Load Lugs Number
125 60 (1) #8-#3 CU; #8-#3 AL THQL2160 125 70 (1) #6-1/0 CU; #4-#1/0 AL THQL2170 125 80 (1) #6-1/0 CU; #4-#1/0 AL THQL2180 125 90 (1) #6-1/0 CU; #4-#1/0 AL THQL2190 125 100 (1) #2-2/0 CU; #2-2/0 AL THQL21100 125 110 THQL21110 125 125 (1) #2-2/0 CU; #2-2/0 AL THQL21125 125 125 TMQL21125SF 200 100 (1) #1-300 CU; #1-300 AL TQD22100 200 125 (1) #1-300 CU; #1-300 AL TQD22125 200 150 (1) #1-300 CU; #1-300 AL TQD22150 200 175 (1) #1-300 CU; #1-300 AL TQD22175 200 200 (1) #1-300 CU; #1-300 AL TQD22200 200 225 Use TMQD
2
Tenant Main Circuit Breakers 22,000 AIC
Socket Amps Ampere Rating Load Lugs Number
125 60 (1) #8-3 CU; #8-2 AL THHQL2160 125 70 (1) #6-1/0 CU; (1) #4 1/0 THHQL2170 125 80 (1) #6-1/0 CU; #4-1/0 AL THHQL2180 125 90 (1) #6-1/0 CU; #4-1/0 AL THHQL2190 125 100 (1) #6-1/0 CU; #4-1/0 AL THHQL21100 125 110 THHQL21110 125 125 (1) #2-2/0 CU; # 2-2/ AL THHQL21125 200 100 (1) #1-300 CU; #1-300 AL THQD22100 200 125 (1) #1-300 CU; #1-300 AL THQD22125 200 150 (1) #1-300 CU; #1-300 AL THQD22150 200 175 (1) #1-300 CU; #1-300 AL THQD22175 200 200 (1) #1-300 CU; #1-300 AL THQD22200 200 225 Use TMQD
Wire Size Product
Tenant Main Circuit Breakers 42,000 AIC
Wire Size Product
Socket Amps Ampere Rating Load Lugs Number
125 60 (1) #10-1/0 CU; #10-1/0 AL TMQL2160 125 70 (1) #10-1/0 CU; #10-1/0 AL TMQL2170 125 80 (1) #10-1/0 CU; #10-1/0 AL TMQL2180 125 90 (1) #10-1/0 CU; #10-1/0 AL TMQL2190 125 100 (1) #10-1/0 CU; #10-1/0 AL TMQL21100 125 125 (1) #10-1/0 CU; #10-1/0 AL TMQL21125
Tenant Main Circuit Breakers 100,000 AIC
Wire Size Product Socket Amps Ampere Rating Load Lugs Number
200 60 (1) #6-1/0 CU; #6-1/0 AL TMQD22060 200 70 (1) #6-1/0 CU; #6-1/0 AL TMQD22070 200 80 (1) #6-1/0 CU; #6-1/0 AL TMQD22080 200 90 (1) #6-1/0 CU; #6-1/0 AL TMQD22090 200 100 (1) #6-4/0 CU; #6-4/0 AL TMQD22100 200 125 (1) #6-4/0 CU; #6-4/0 AL TMQD22125 200 150 (1) #6-4/0 CU; #6-4/0 AL TMQD22150
4
200 175 (1) #6-4/0 CU; #6-4/0 AL TMQD22175
4
200 200 (1) #6-4/0 CU; #6-4/0 AL TMQD22200 200 225 (1) #6-4/0 CU; #6-4/0 AL TMQD22225
1
Available with factory installed horn-type by-pass. Add HB suffix to Product
Number. Includes factory installed fifth jaw.
2
Includes horn by-pass.
3
Sub-feed lug, no overcurrent protection.
4
For Florida units, add "F" suffix to the product number. (For example, TMP8212R
4
becomes TMP8212RF.) These units have an additional cotter pin that has been added to the meter socket assembly that will keep the meter socket from detach­ing from the base. This change meets the new MEG requirements and should not be used outside of the state of Florida.
5
For products with horned bypass factory installed in the unit , add "HB" suffix to the
product number. (For example, TMPR8212R becomes TMPR8212RHB.)
3
Rev. 11/13
Data subject to change without notice
BuyLog™Catalog
2-17
Molded Case Circuit Breakers
Q-Line Circuit Breakers
Cable-in Cable-out (lug-lug) 240V Class
TQD 240 Vac, Internal Common Trip
# of Ampere 240 Vac Poles Rating Interrupting Rating Product Number
2 100 10kA TQD22100WL 2 125 10kA TQD22125WL 2 150 10kA TQD22150WL 2 175 10kA TQD22175WL 2 200 10kA TQD22200WL 2 225 10kA TQD22225WL 3 100 10kA TQD32100WL 3 125 10kA TQD32125WL 3 150 10kA TQD32150WL 3 175 10kA TQD32175WL 3 200 10kA TQD32200WL 3 225 10kA TQD32225WL
Section 6
1,2
TJD432400WL
TQD 240 Vac, Internal Common Trip with Factory Installed 120 Vac Shunt Trip
# of Ampere 240 Vac Poles Rating Interrupting Rating Product Number
3 125 10kA TQD32125ST1 3 150 10kA TQD32150ST1 3 175 10kA TQD32175ST1 3 200 10kA TQD32200ST1 3 225 10kA TQD32225ST1
THQD 240 Vac, Internal Common Trip
# of Ampere 240 Vac Poles Rating Interrupting Rating Product Number
2 100 22kA THQD22100WL 2 125 22kA THQD22125WL 2 150 22kA THQD22150WL 2 175 22kA THQD22175WL 2 200 22kA THQD22200WL 2 225 22kA THQD22225WL 3 100 22kA THQD32100WL 3 125 22kA THQD32125WL 3 150 22kA THQD32150WL 3 175 22kA THQD32175WL 3 200 22kA THQD32200WL 3 225 22kA THQD32225WL
TJD 240 Vac, Internal Common Trip
# of Ampere 240 Vac Poles Rating Interrupting Rating Product Number
2 250 22kA TJD422250WL 2 300 22kA TJD422300WL 2 350 22kA TJD422350WL 2 400 22kA TJD422400WL 2 400 Molded Case Switch 22kA TJD422Y400 3 250 22kA TJD432250WL 3 300 22kA TJD432300WL 3 350 22kA TJD432350WL 3 400 22kA TJD432400WL 3 400 Molded Case Switch 22kA TJD432Y400
1
Refer to table on page 6-103 for lug and wire range data.
2
Includes line and load lugs. For optional configurations see page 6-3.
3
For additional shunt trip options see page 6-41.
4
TJD uses same accessories as J600 line. TJD not listed HACR.
UL listed HACR (heating, air conditioning and refrigeration).
3
1,2
1,2
1,2
4
4
4
4
4
6-28
BuyLog™Catalog
Rev. 11/13
Data subject to change without notice
Section 11Panelboards
A-Series™Panelboards
Pro-Stock, Unassembled Lighting Panels
5
Typical Main Breakers
—Skip Step 5 if you selected a main breaker kit ending in “WB” —
no breaker is required.
—To correlate breaker types with the kAIC rating in specific panel-
—All TQD and Spectra —For TEY and THQB main breakers, see branch breakers tables in
Step 7. boards, see the table for Step 4. For more rating details, see A-Series
Lighting Panels Rating Series Labels (DEH-40007).
Digital, Solid State Spectra™RMS Breakers (3-pole) For use with appropriate main breaker kit (see Step 4).
Breaker Rating Plug
Poles Sensor Product Number Rating Product Number Product Number (Cu/Al)
1
Any rating plug within a given current sensor group may be paired with any breaker in that group.
2
Except for “WB” kits, lugs must be ordered separately for Spectra™breakers. All Spectra™breakers also require an appropriate rating plug.
Current Amp Wire Range
SEDA36AT0100
100
150 SELA36AT0150 125 SRPE150A125
3 70 SRPF250A70
250
3 400
2 400 SGLA26AT0400 300 SRPG400A300 TCLK265 #6-600 MCM
3 600
2 600 SGLA26AT0600 500 SRPG600A500 TCLK265
SEHA36AT0100 SELA36AT0100 SEPA36AT0100 TCAL18 #12-3/0 SEDA36AT0150 110 SRPE150A110
SEPA36AT0150 150 SRPE150A150
SFLA36AT0250 125 SRPF250A125 TCAL29 #8-350 MCM SFPA36AT0250 150 SRPF250A150
SGHA36AT0400 150 SRPG400A150 SGLA36AT0400 175 SRPG400A175 TCLK365 SGPA36AT0400 200 SRPG400A200
SGHA26AT0400 250 SRPG400A250 MCM or (1)
SGPA26AT0400 350 SRPG400A350 Cu: (2) 2/0-400
SGLA36AT0600 SGPA36AT0600
SGPA26AT0600 600 SRPG600A600
100 SRPE100A100
90 SRPF250A90 100 SRPF250A100 110 SRPF250A110
175 SRPF250A175 200 SRPF250A200 225 SRPF250A225 125 SRPG400A125
225 SRPG400A225 Al: (2) 2/0-500
400 SRPG400A400 MCM or (1) 250 SRPG600A250 #8-600 MCM 300 SRPG600A300 TCLK365 350 SRPG600A350 400 SRPG600A400
1
Main or subfeed breakers for use with AQ panels (208/120 Vac 3-phase or 240 Vac single phase). See Step 4.
10kAIC 22kAIC 10kAIC 22kAIC
Amp Product
Rating Number Number Number Number
100 TQD22100X2 THQD22100X2 TQD32100X2 THQD32100X2 125 TQD22125X2 THQD22125X2 TQD32125X2 THQD32125X2 150 TQD22150X2 THQD22150X2 TQD32150X2 THQD32150X2 175 TQD22175X2 THQD22175X2 TQD32175X2 THQD32175X2 200 TQD22200X2 THQD22200X2 TQD32200X2 THQD32200X2 225 TQD22225X2 THQD22225X2 TQD32225X2 THQD32225X2 250 TJD422250L2 TJD432250L3 300 TJD422300L2 TJD432300L3 350 TJD422350L2 TJD432350L3 400 TJD422400L2 TJD432400L3
3
2-pole 3-pole
Product Product
Main or subfeed breakers for use with AE panels (480/277 Vac 3-phase). See Step 4.
3-pole
Amp Rating Product Number Product Number Product Number
100 TED134110WL THED134110WL MB233WB 125 TED134125WL THED134125WL MB233WB 150 TED134150WL THED134150WL MB233WB 175 –– MB233WB 200 –– MB233WB 225 –– MB233WB 250 –– TJJ436250L3 300 –– TJJ436300L3 350 –– TJJ436350L3 400 –– TJJ436400L3
3
Any load-side lugs on TQD breakers must be removed before assembly. TQD breakers with X2 product number suffix feature line-side lugs only.
18kAIC 22kAIC 30kAIC
main breakers require line-side lugs.
Terminal Lugs for Front Connection
3
Product
2
11-16
BuyLog™Catalog
Rev. 11/13
Data subject to change without notice
Loading...