IEC Power Devices
Mini Contactors Technical Information
C-2000
Mini Contactors and Control Relays
Operating Characteristics/Technical Data:
Standards and Listings
International Certification Marks: In addition to stating the
product number, the contactor nameplate also lists the international certification marks. All contactors, control relays, overload
relays, and accessories are UL and cUL listed.
Contactors and relays also conform to International Standards:
—UL listed (Underwriters Laboratories, U.S. -UL 508, cUL);
—CE Mark;
—IEC 947-1,4 (International Electrotechnical Commission);
—BS 5424 (British Standards, UK);
—VDE 0660 (Verband Deutscher Elektotechniker, Federal
Republic of Germany);
—(S) (SEV, Switzerland-SEV 10254);
—(D) (DEMCO, Denmark);
—(N) (NEMCO, Norway);
—(FI) (SETI, Finland);
plus other specifications approvals...
—CEI 17-3, 17-7 (Comitato Electrotechnico Italiano, Italy);
—Bureau Veritas, France;
—SEMKO, Sweden.
Contactors and Control Relays
Ambient Conditions
Operating Temperature –20 to +55°C (–4 to +131°F)
Storage Temperature –30 to +80°C (–22 to +176°F)
Altitude
Derating Up to 10,000 ft . (3,000 m) Rated current
Derating 10,000 to 13,200 ft . (3,000 to 4,000 m) .9 x’s rated current
Derating 13,200 to 16,000 ft . (4,000 to 5,000 m) .8 x’s rated current
Shock Resistance (All Axis)
Closed 80% voltage - Admissible accel. 30g
Closed 80% voltage - Impulse duration 11 ms
Open no voltage - Admissible acceleration 10g
Open no voltage - Impulse duration 11 ms
Vibration Resistance
Closed 80% voltage-Admissible accel. 10g
Closed 80% voltage - Sweep between 10-200 hz
Open No voltage-Admissible accel. 5g
Open No voltage - Impulse duration 10-200 hz
Terminal Capacity
Screw Terminal Wire size (2) #14-18 AWG max.
Screw Terminal Wire temperature class 60°C/75°C wire
Quick connect (Faston 2.8mm) Wire size (2) 1mm
Quick connect (Faston 2.8mm) Max. thermal current 8 amps
Printed circuit terminal - Hole size 1.8mm
Tightening Torque 7 inch lbs.
2
Operating Position
Control Catalog
5-31
IEC Power Devices
Mini Contactors Technical Information
C-2000
Main Contacts Data - Contactors
Rated insulation voltage (IEC 947-1) 660V
Rated thermal current (UL 508) 16 amps
Frequency limits 25-400 Hz
Impedance per pole 1.76 m ohm
Power dissipation AC-1 0.7 W
Power dissipation AC-3 .13W
Insulation resistance >10 m ohm
No overlap between NO and NC contacts - Space 1mm
No overlap between NO and NC contacts - Time >2ms
Main Contacts Data - Control Relays
Rated insulation voltage (IEC 947-1) 660V
Rated thermal current (UL 508) 10 amps
Contact Rating A600, Q600
Frequency limits 25-400 Hz
Impedance per pole 2.4 m ohm
No overlap between NO and NC contacts - Space 1.1mm
No overlap between NO and NC contacts - Time >2ms
Instantaneous Auxiliary Contact Data
Rated insulation voltage (IEC 947-1) 660V
Rated thermal current (UL 508) 10 amps
Contact Rating A600, Q600
Frequency limits 25-400 Hz
Impedance per pole 2.4 m ohm
Insulation resistance >10 m ohm
No overlap between NO and NC contacts - Space 1mm
No overlap between NO and NC contacts - Time >2ms
Overload Relay Auxiliary Contact Data
Rated insulation voltage (IEC 947-1) 660V
Rated thermal current (UL 508) 6 amps
Contact Rating B600, R300
Frequency limits 25-400 Hz
Control Circuit Ratings
120 Vac, 125 Vdc
Carry Continuous Make Momentary
Time Rating Amperes Amperes Break Amperes
A600 AC 10 60 6
B600 AC 5 30 3
Q600 DC 2.5 0.55 0.55
R300 DC 1.0 0.22 0.22
For other voltages, reference NEMA ICS 3-125 or contact your nearest GE Energy
Representative.
Control Circuit Data: Pickup/Dropout % Coil Voltage
Type Coil Pick-up Drop-out
AC Controlled 80%-110% 35%-55%
DC Controlled 80%-110% 20%-40%
PLC interface (1.2w) 80%-125% 20%-30%
PLC interface (2w) 70%-125% 20%-35%
Opening/Closing Time
Making (on Energization) (ms) Breaking (on De-energization) (ms)
Type Coil Voltage NO Contact NC Contact NO Contact NC Contact
AC Controlled (ms) +10-15% 6-13 8-16 5-11 6-13
Nominal 7-12 8-16 6-10 6-13
DC Controlled (ms) +10-15% 22-36 9-12 18-27 5-7
Nominal 24-27 9-11 20-26 5-8
PLC Interface (1.2w) (ms) +25-20% 30-70 9-16 20-45 5-9
Nominal 25-45 9-16 25-35 5-9
PLC Interface (2w) (ms) +25-30% 20-50 9-16 18-35 5-9
Nominal 25-40 9-16 20-30 5-9
Maximum Operating Rate
Operations per Hour
No load 9000 OPS/H
AC1 and AC3 at rated power 1200 OPS/H
AC4 at rated power 300 OPS/H
Coil Consumption
Pick-up Pick-up Holding Holding Power Dissipation
Type Coil (Watts) (VA) (Watts) (VA) (Watts)
AC Controlled 26 4 1.4
DC Controlled 3 3
PLC Interface (1.2w) 1.2 1.2
PLC Interface (2w) 2 2
5-32
Control Catalog