IEC Manual Motor Starters
Accessories
Front Mounted (Internal) Accessories—Auxiliary and Alarm Contacts
Snap away the dust cover(s) and up to two front mounted accessories slide into the
starter, increasing application flexibility without increasing width.
Accessory Type For Use With Position Configuration Number GO-10A2C
Auxiliary Contact (Front Mount) GPS1*/GPS2* Left or right front 1NC GPAC01FBA
Auxiliary Contact (Front Mount) GPS1*/GPS2* Left or right front 1NO GPAC10FBA
Alarm Contact (Front Mount) GPS1*/GPS2* Right front 1NC GPAL01FRA
Alarm Contact (Front Mount) GPS1*/GPS2* Right front 1NO GPAL10FRA
Front Aux. Position Cover
(Package of 10) GPS1*/GPS2* Left or right front N/A GPAC0VF1A
Mounting Contact Product
Side Mounted Accessories—Auxiliary and Alarm Contacts
Snap on accessories - maximum of [(2) auxiliary contact blocks] or [(1) auxiliary contact
block plus (1) alarm/aux. block or (1) short circuit indicator] or [(1) alarm/auxiliary plus (1)
short circuit indicator] left and (2) auxiliary contact blocks or (1) shunt trip or (1) undervoltage release right.
Accessory Type For Use With Position Configuration Number GO-10A2C
Auxiliary Contact (Side Mount GPS1*/GPS2* Left 2NC GPAC02LLA
Auxiliary Contact (Side Mount) GPS1*/GPS2* Left 1NO + 1NC GPAC11LLA
Auxiliary Contact (Side Mount) GPS1*/GPS2* Left 2NO GPAC20LLA
Auxiliary Contact (Side Mount) GPS1*/GPS2* Right 2NC GPAC02LRA
Auxiliary Contact (Side Mount) GPS1*/GPS2* Right 1NO + 1NC GPAC11LRA
Auxiliary Contact (Side Mount) GPS1*/GPS2* Right 2NO GPAC20LRA
Alarm/Auxiliary Contact (Side Mount) GPS1*/GPS2* Left 1NC Alarm + 1NC Aux. GPAD0101LLA
Alarm/Auxiliary Contact (Side Mount) GPS1*/GPS2* Left 1NC Alarm + 1NO Aux. GPAD0110LLA
Alarm/Auxiliary Contact (Side Mount) GPS1*/GPS2* Left 1NO Alarm + 1NC Aux. GPAD1001LLA
Alarm/Auxiliary Contact (Side Mount) GPS1*/GPS2* Left 1NO Alarm + 1NO Aux. GPAD1010LLA
Short Circuit Alarm (Side Mount) GPS1*/GPS2* Left 1NO + 1NC GPAE11LLA
1
GPS1BSAR and GPS1BHAR (24-32 FLA starters) can accept all accessory combinations noted above except that
only one lateral auxiliary contact block may be used on this size.
2
GPAE11LLA short circuit alarm may not be used with non-metallic enclosures due to reset button interference.
Mounting Contact Product
1
1
1
1
1
1
2
Section 6
GPAC_ _ FB A
Front Mounte d Auxi li ar y Contacts
GPAC_ _ FR A
Front Mounte d Alar m Cont ac ts
GPAC_ _ LL A/GPAC_ _LRA
Side M ou nt ed Auxiliary Contacts
GPAD_ _ _ _LLA
Side M ou nt ed Alarm/Auxiliary Contact
GPAE11LLA
Side M ou nt ed Shor t Circuit Alarm
Rev. 8/15
Prices and data subject to
change without notice
Terminal Identification and Wiring Diagrams:
See page 6-42
Control Catalog
6-7
IEC Manual Motor Starters
Accessories
Side Mounted Accessories—Shunt Trip
Snap on accessories - maximum of (2) auxiliary contact blocks or (1) shunt trip or (1)
underv
oltage release right side.
Accessory Type For Use With Position Coil Voltage Number GO-10A2C
Shunt Trip GPS1*/GPS2* Right 24V 60/50 Hz GPASLRAA1
Shunt Trip GPS1*/GPS2* Right 48V 60 Hz GPASLRAAF
Shunt Trip GPS1*/GPS2* Right 60V 60 Hz, 48V 50 Hz GPASLRAAG
Shunt Trip GPS1*/GPS2* Right 120V 60 Hz, 110-127V 50 Hz GPASLRAAJ
Shunt Trip GPS1*/GPS2* Right 208V 60 Hz GPASLRAAM
Shunt Trip GPS1*/GPS2* Right 240V 60 Hz, 220V 50 Hz GPASLRAAN
Shunt Trip GPS1*/GPS2* Right 277V 60 Hz, 240V 50 Hz GPASLRAAR
Shunt Trip GPS1*/GPS2* Right 380/400V 50 Hz GPASLRAAU
Shunt Trip GPS1*/GPS2* Right 460-480V 60 Hz, 415-440V 50 Hz GPASLRAAW
Shunt Trip GPS1*/GPS2* Right 600V 60 Hz, 500V 50 Hz GPASLRAAY
Shunt Trip GPS1*/GPS2* Right 24-60V DC GPASLRADD
Shunt Trip GPS1*/GPS2* Right 110-240V DC GPASLRADJ
De-energizes the controller when external signal is applied to shunt coil.
Side Mounted Accessories—Undervoltage Release
Snap on accessories - maximum of (2) auxiliary contact blocks or (1) shunt trip or (1)
underv
oltage release right side.
Accessory Type For Use With Position Coil Voltage Number GO-10A2C
Undervoltage Release GPS1*/GPS2* Right 24V 60 Hz GPAULRAAC
Undervoltage Release GPS1*/GPS2* Right 24V 50 Hz GPAULRAAD
Undervoltage Release GPS1*/GPS2* Right 48V 60 Hz GPAULRAAF
Undervoltage Release GPS1*/GPS2* Right 48V 50 Hz GPAULRAAG
Undervoltage Release GPS1*/GPS2* Right 120V 60Hz, 110-127V 50 Hz GPAULRAAJ
Undervoltage Release GPS1*/GPS2* Right 208V 60 Hz GPAULRAAM
Undervoltage Release GPS1*/GPS2* Right 240-260V 60 Hz, 220/230V 50 Hz GPAULRAAN
Undervoltage Release GPS1*/GPS2* Right 277V 60 Hz, 240V 50 Hz GPAULRAAR
Undervoltage Release GPS1*/GPS2* Right 380/400V 50 Hz GPAULRAAU
Undervoltage Release GPS1*/GPS2* Right 460-480V 60 Hz, 415-440V 50 Hz GPAULRAAW
Undervoltage Release GPS1*/GPS2* Right 600V 60 Hz, 500V 50 Hz GPAULRAAY
Provides protection from low voltage conditions; requires 85-110% voltage across D1 and D2 prior to starting
motor; requires reset of starter upon undervoltage condition or loss of voltage.
Side Mounted Accessories—Undervoltage Release
Snap on accessories - maximum of (2) auxiliary contact blocks or (1) shunt trip or (1)
un
dervoltage release right side.
Accessory Type For Use With Position Coil Voltage Number GO-10A2C
Undervoltage Release GPS1BS* Right 24V 60 Hz GPAU20LTAAC
Undervoltage Release GPS1BS* Right 24V 50 Hz GPAU20LTAAD
Undervoltage Release GPS1BS* Right 48V 60 Hz GPAU20LTAAF
Undervoltage Release GPS1BS* Right 48V 50 Hz GPAU20LTAAG
Undervoltage Release GPS1BS* Right 120V 60 Hz, 110-127V 50 Hz GPAU20LTAAJ
Undervoltage Release GPS1BS* Right 208V 60 Hz GPAU20LTAAM
Undervoltage Release GPS1BS* Right 240-260V 60 Hz, 220/230V 50 Hz GPAU20LTAAN
Undervoltage Release GPS1BS* Right 277V 60 Hz, 240V 50 Hz GPAU20LTAAR
Undervoltage Release GPS1BS* Right 380/400V 50 Hz GPAU20LTAAU
Undervoltage Release GPS1BS* Right 460-480V 60 Hz, 415-440V 50 Hz GPAU20LTAAW
Undervoltage Release GPS1BS* Right 600V 60 Hz, 500V 50 Hz GPAU20LTAAY
With 2NO early make contacts (provides protection from low voltage conditions; early make contacts energize
release coil when operator is turned to ON position and voltage is 85-110% Ve; requires reset of starter upon
undervoltage condition or loss of voltage)
Side Mounted Accessories—Undervoltage Release
Snap on accessories - maximum of (2) auxiliary contact blocks] or (1) shunt trip or (1)
underv
oltage release right side.
Accessory Type For Use With Position Coil Voltage Number GO-10A2C
Undervoltage Release GPS1BH*/GPS2BH* Right 24V 60 Hz GPAU20LCAAC
Undervoltage Release GPS1BH*/GPS2BH* Right 24V 50 Hz GPAU20LCAAD
Undervoltage Release GPS1BH*/GPS2BH* Right 48V 60 Hz GPAU20LCAAF
Undervoltage Release GPS1BH*/GPS2BH* Right 48V 50 Hz GPAU20LCAAG
Undervoltage Release GPS1BH*/GPS2BH* Right 120V 60 Hz, 110-127V 50 Hz GPAU20LCAAJ
Undervoltage Release GPS1BH*/GPS2BH* Right 208V 60 Hz GPAU20LCAAM
Undervoltage Release GPS1BH*/GPS2BH* Right 240-260V 60 Hz, 220/230V 50 Hz GPAU20LCAAN
Undervoltage Release GPS1BH*/GPS2BH* Right 277V 60 Hz, 240V 50 Hz GPAU20LCAAR
Undervoltage Release GPS1BH*/GPS2BH* Right 380/400V 50 Hz GPAU20LCAAU
Undervoltage Release GPS1BH*/GPS2BH* Right 460-480V 60 Hz, 415-440V 50 Hz GPAU20LCAAW
Undervoltage Release GPS1BH*/GPS2BH* Right 600V 60 Hz, 500V 50 Hz GPAU20LCAAY
With 2NO early make contacts (provides protection from low voltage conditions; early make contacts energize
release coil when operator is turned to ON position and voltage is 85-110% Ve; requires reset of starter upon
undervoltage condition or loss of voltage)
Mounting Product
Mounting Product
Mounting Product
Mounting Product
Section 6
GPASLRA_ _Shunt Trip
GPAULRAA_Undervoltage Rel ea se
GPAU20LTAA_Underv ol ta ge Release
with 2NO ea rl y make contacts
GPAU20LCAA_Undervoltage Release
with 2NO ea rl y make contacts
6-8
Control Catalog
Rev. 8/15
Prices and data subject to
change without notice