GE - General Electric IEC Manual Motor Starters Accessories Catalog

IEC Manual Motor Starters
Accessories
Front Mounted (Internal) Accessories—Auxiliary and Alarm Contacts
Snap away the dust cover(s) and up to two front mounted accessories slide into the starter, increasing application flexibility without increasing width.
Accessory Type For Use With Position Configuration Number GO-10A2C
Auxiliary Contact (Front Mount) GPS1*/GPS2* Left or right front 1NC GPAC01FBA Auxiliary Contact (Front Mount) GPS1*/GPS2* Left or right front 1NO GPAC10FBA Alarm Contact (Front Mount) GPS1*/GPS2* Right front 1NC GPAL01FRA Alarm Contact (Front Mount) GPS1*/GPS2* Right front 1NO GPAL10FRA Front Aux. Position Cover
(Package of 10) GPS1*/GPS2* Left or right front N/A GPAC0VF1A
Mounting Contact Product
Side Mounted Accessories—Auxiliary and Alarm Contacts
Snap on accessories - maximum of [(2) auxiliary contact blocks] or [(1) auxiliary contact block plus (1) alarm/aux. block or (1) short circuit indicator] or [(1) alarm/auxiliary plus (1) short circuit indicator] left and (2) auxiliary contact blocks or (1) shunt trip or (1) under­voltage release right.
Accessory Type For Use With Position Configuration Number GO-10A2C
Auxiliary Contact (Side Mount GPS1*/GPS2* Left 2NC GPAC02LLA Auxiliary Contact (Side Mount) GPS1*/GPS2* Left 1NO + 1NC GPAC11LLA Auxiliary Contact (Side Mount) GPS1*/GPS2* Left 2NO GPAC20LLA Auxiliary Contact (Side Mount) GPS1*/GPS2* Right 2NC GPAC02LRA Auxiliary Contact (Side Mount) GPS1*/GPS2* Right 1NO + 1NC GPAC11LRA Auxiliary Contact (Side Mount) GPS1*/GPS2* Right 2NO GPAC20LRA Alarm/Auxiliary Contact (Side Mount) GPS1*/GPS2* Left 1NC Alarm + 1NC Aux. GPAD0101LLA Alarm/Auxiliary Contact (Side Mount) GPS1*/GPS2* Left 1NC Alarm + 1NO Aux. GPAD0110LLA Alarm/Auxiliary Contact (Side Mount) GPS1*/GPS2* Left 1NO Alarm + 1NC Aux. GPAD1001LLA Alarm/Auxiliary Contact (Side Mount) GPS1*/GPS2* Left 1NO Alarm + 1NO Aux. GPAD1010LLA Short Circuit Alarm (Side Mount) GPS1*/GPS2* Left 1NO + 1NC GPAE11LLA
1
GPS1BSAR and GPS1BHAR (24-32 FLA starters) can accept all accessory combinations noted above except that
only one lateral auxiliary contact block may be used on this size.
2
GPAE11LLA short circuit alarm may not be used with non-metallic enclosures due to reset button interference.
Mounting Contact Product
1
1
1
1
1
1
2
Section 6
GPAC_ _ FB A
Front Mounte d Auxi li ar y Contacts
GPAC_ _ FR A
Front Mounte d Alar m Cont ac ts
GPAC_ _ LL A/GPAC_ _LRA
Side M ou nt ed Auxiliary Contacts
GPAD_ _ _ _LLA
Side M ou nt ed Alarm/Auxiliary Contact
GPAE11LLA
Side M ou nt ed Shor t Circuit Alarm
Rev. 8/15
Prices and data subject to change without notice
Terminal Identification and Wiring Diagrams:
See page 6-42
Control Catalog
6-7
IEC Manual Motor Starters
Accessories
Side Mounted Accessories—Shunt Trip
Snap on accessories - maximum of (2) auxiliary contact blocks or (1) shunt trip or (1) underv
oltage release right side.
Accessory Type For Use With Position Coil Voltage Number GO-10A2C
Shunt Trip GPS1*/GPS2* Right 24V 60/50 Hz GPASLRAA1 Shunt Trip GPS1*/GPS2* Right 48V 60 Hz GPASLRAAF Shunt Trip GPS1*/GPS2* Right 60V 60 Hz, 48V 50 Hz GPASLRAAG Shunt Trip GPS1*/GPS2* Right 120V 60 Hz, 110-127V 50 Hz GPASLRAAJ Shunt Trip GPS1*/GPS2* Right 208V 60 Hz GPASLRAAM Shunt Trip GPS1*/GPS2* Right 240V 60 Hz, 220V 50 Hz GPASLRAAN Shunt Trip GPS1*/GPS2* Right 277V 60 Hz, 240V 50 Hz GPASLRAAR Shunt Trip GPS1*/GPS2* Right 380/400V 50 Hz GPASLRAAU Shunt Trip GPS1*/GPS2* Right 460-480V 60 Hz, 415-440V 50 Hz GPASLRAAW Shunt Trip GPS1*/GPS2* Right 600V 60 Hz, 500V 50 Hz GPASLRAAY Shunt Trip GPS1*/GPS2* Right 24-60V DC GPASLRADD Shunt Trip GPS1*/GPS2* Right 110-240V DC GPASLRADJ
De-energizes the controller when external signal is applied to shunt coil.
Side Mounted Accessories—Undervoltage Release
Snap on accessories - maximum of (2) auxiliary contact blocks or (1) shunt trip or (1) underv
oltage release right side.
Accessory Type For Use With Position Coil Voltage Number GO-10A2C
Undervoltage Release GPS1*/GPS2* Right 24V 60 Hz GPAULRAAC Undervoltage Release GPS1*/GPS2* Right 24V 50 Hz GPAULRAAD Undervoltage Release GPS1*/GPS2* Right 48V 60 Hz GPAULRAAF Undervoltage Release GPS1*/GPS2* Right 48V 50 Hz GPAULRAAG Undervoltage Release GPS1*/GPS2* Right 120V 60Hz, 110-127V 50 Hz GPAULRAAJ Undervoltage Release GPS1*/GPS2* Right 208V 60 Hz GPAULRAAM Undervoltage Release GPS1*/GPS2* Right 240-260V 60 Hz, 220/230V 50 Hz GPAULRAAN Undervoltage Release GPS1*/GPS2* Right 277V 60 Hz, 240V 50 Hz GPAULRAAR Undervoltage Release GPS1*/GPS2* Right 380/400V 50 Hz GPAULRAAU Undervoltage Release GPS1*/GPS2* Right 460-480V 60 Hz, 415-440V 50 Hz GPAULRAAW Undervoltage Release GPS1*/GPS2* Right 600V 60 Hz, 500V 50 Hz GPAULRAAY
Provides protection from low voltage conditions; requires 85-110% voltage across D1 and D2 prior to starting
motor; requires reset of starter upon undervoltage condition or loss of voltage.
Side Mounted Accessories—Undervoltage Release
Snap on accessories - maximum of (2) auxiliary contact blocks or (1) shunt trip or (1) un
dervoltage release right side.
Accessory Type For Use With Position Coil Voltage Number GO-10A2C
Undervoltage Release GPS1BS* Right 24V 60 Hz GPAU20LTAAC Undervoltage Release GPS1BS* Right 24V 50 Hz GPAU20LTAAD Undervoltage Release GPS1BS* Right 48V 60 Hz GPAU20LTAAF Undervoltage Release GPS1BS* Right 48V 50 Hz GPAU20LTAAG Undervoltage Release GPS1BS* Right 120V 60 Hz, 110-127V 50 Hz GPAU20LTAAJ Undervoltage Release GPS1BS* Right 208V 60 Hz GPAU20LTAAM Undervoltage Release GPS1BS* Right 240-260V 60 Hz, 220/230V 50 Hz GPAU20LTAAN Undervoltage Release GPS1BS* Right 277V 60 Hz, 240V 50 Hz GPAU20LTAAR Undervoltage Release GPS1BS* Right 380/400V 50 Hz GPAU20LTAAU Undervoltage Release GPS1BS* Right 460-480V 60 Hz, 415-440V 50 Hz GPAU20LTAAW Undervoltage Release GPS1BS* Right 600V 60 Hz, 500V 50 Hz GPAU20LTAAY
With 2NO early make contacts (provides protection from low voltage conditions; early make contacts energize
release coil when operator is turned to ON position and voltage is 85-110% Ve; requires reset of starter upon undervoltage condition or loss of voltage)
Side Mounted Accessories—Undervoltage Release
Snap on accessories - maximum of (2) auxiliary contact blocks] or (1) shunt trip or (1) underv
oltage release right side.
Accessory Type For Use With Position Coil Voltage Number GO-10A2C
Undervoltage Release GPS1BH*/GPS2BH* Right 24V 60 Hz GPAU20LCAAC Undervoltage Release GPS1BH*/GPS2BH* Right 24V 50 Hz GPAU20LCAAD Undervoltage Release GPS1BH*/GPS2BH* Right 48V 60 Hz GPAU20LCAAF Undervoltage Release GPS1BH*/GPS2BH* Right 48V 50 Hz GPAU20LCAAG Undervoltage Release GPS1BH*/GPS2BH* Right 120V 60 Hz, 110-127V 50 Hz GPAU20LCAAJ Undervoltage Release GPS1BH*/GPS2BH* Right 208V 60 Hz GPAU20LCAAM Undervoltage Release GPS1BH*/GPS2BH* Right 240-260V 60 Hz, 220/230V 50 Hz GPAU20LCAAN Undervoltage Release GPS1BH*/GPS2BH* Right 277V 60 Hz, 240V 50 Hz GPAU20LCAAR Undervoltage Release GPS1BH*/GPS2BH* Right 380/400V 50 Hz GPAU20LCAAU Undervoltage Release GPS1BH*/GPS2BH* Right 460-480V 60 Hz, 415-440V 50 Hz GPAU20LCAAW Undervoltage Release GPS1BH*/GPS2BH* Right 600V 60 Hz, 500V 50 Hz GPAU20LCAAY
With 2NO early make contacts (provides protection from low voltage conditions; early make contacts energize
release coil when operator is turned to ON position and voltage is 85-110% Ve; requires reset of starter upon undervoltage condition or loss of voltage)
Mounting Product
Mounting Product
Mounting Product
Mounting Product
Section 6
GPASLRA_ _Shunt Trip
GPAULRAA_Undervoltage Rel ea se
GPAU20LTAA_Underv ol ta ge Release
with 2NO ea rl y make contacts
GPAU20LCAA_Undervoltage Release
with 2NO ea rl y make contacts
6-8
Control Catalog
Rev. 8/15
Prices and data subject to change without notice
Loading...