GE - General Electric IEC Electronic Timers Technical Data

Logic Control
IEC Electronic Timers
Multivoltage Electronic Timers
Technical Data
Section 10
**Available Input Voltages
Direct supply Supplied with internal transformer
Current AC (50/60 Hz)/DC AC (50/60Hz)
Voltage 24-240 110-125 200-240 380-400
Product Number Code None AJ AM AU
NMETV
NMETVT
NMICV
NMIFV
NMIVV
NMMFV
NMRDV
NMRDV2 NMRDVT •• ••
NMTCIV
NMTCV
NMTCV2
NMTCVT
NMTDV
available
recommended stock
••
••
••
••
••
••
••
••
••
••
••
••
Rev. 8/15
Prices and data subject to change without notice
Control Catalog
10-17
Section 10Logic Control
IEC Electronic Timers
Multivoltage Electronic Timers
Technical Data
NMTCV Delayed ON Timer
Electronic relay whose output contact connects with a certain adjustable delay from the moment voltage is applied to supply terminals A1-A2. It has four timing ranges: see drawing. Range selection is made by dip-switches located on the front of the relay. Times are set by front potentiometer controlling an Application Specific Integrated Circuit (ASIC) specially designed for this group of relays. This allows for excellent precision and repeatability features.
Product Number NMTCV NMTCV2 NMTCVT
Number of Selectable NO-NC Contacts 121 Output Contacts Rated Insulation Voltage: Ui AC 250V 250V 250V Output Contacts Rated Insulation Voltage: Ui DC 250V 250V 250V Output Contacts Thermal Current Ith 6A 6A 6A Utilization Category AC15 Rated Voltage Ue 120/230V 120/230V 120/230V Utilization Category AC15 Rated Current Ie 2.5/1.3A 2.5/1.3A 2.5/1.3A Utilization Category DC13 Rated Voltage Ue 120/230V 110/230V 110/230V Utilization Category DC13 Rated Current Ie 0.2/0.1A 0.2/0.1A 0.2/0.1A Supply Voltage: AC (with transformer) Un --110-125V, 200-240V, 380-440V Supply Voltage: DC/AC (direct) 24-240V 24-240V - Line Voltage Frequency 50/60 Hz 50/60 Hz 50/60 Hz Supply Voltage Tolerance +10/-20% +10/-20% +10/-15% Consumption (mA) 60 (24V), 15 (240V) 60 (24V), 15 (240V) - Consumption (VA) --3.5 Input Circuit Test Voltage 2 kV 4 kV 4 kV Switch ON Response Time 0.06 sec.-100 hrs. 0.06 sec.-100 hrs. 0.06 sec.-100 hrs. Switch OFF Response Time 150 ms 150 ms 150 ms Reset Time Between 2 Cycles 100 ms 100 ms 100 ms Repeat Accuracy with 0.85 - 1.1 Un 1% 1% 1% Weight 0.120, .26 lbs. 0.120, .26 lbs. 0.120, .26 lbs. Approval & Standards VDE 0106, VDE 0110, EN 50001, EN 50002, CSA C 22.2 N° 14, UL 94, UL 508, IEC 255.5
For ambient conditions data see page 10-24, Table 2. The relays have a green LED that lights when the relay is energized (flashing during the timing) and a red LED that
lights when the output contact is made.
10-18
Control Catalog
Rev. 8/15
Prices and data subject to change without notice
Section 10Logic Control
IEC Electronic Timers
Multivoltage Electronic Timers
Technical Data
NMETV Star-Delta Starter Timer
Electronic relay timed in steps whose purpose is to control star-delta starting. When supply voltage is applied to the A1-A2 terminals, the star contact (17-18) closes for an adjustable time between 6 and 60 sec. (selectable). When this time is up, it opens, there is a pause and then the delta contact connects (17-18). The standard pause time is about 100ms. Times are set by front potentiometer controlling an ASIC specially designed for this group of relays. This allows for excellent precision and repeatability features.
Product Number NMETV NMET VT
Number of Selectable NO-NC Contacts 22 Output Contacts Rated Insulation Voltage: Ui AC 250V 250V Output Contacts Rated Insulation Voltage: Ui DC 250V 250V Output Contacts Thermal Current Ith 6A 6A Utilization Category AC15 Rated Voltage Ue 120/230V 120/230V Utilization Category AC15 Rated Current Ie 2.5/1.3A 2.5/1.3A Utilization Category DC13 Rated Voltage Ue 110/230V 110/230V Utilization Category DC13 Rated Current Ie 0.2/0.1A 0.2/0.1A Supply Voltage: AC (with transformer) Un - 110-125V, 200-240V, 380-440V Supply Voltage: DC/AC (direct) Un 24-240V ­Line Voltage Frequency 50/60 Hz 50/60 Hz Supply Voltage Tolerance +10/-20% +10/-15% Consumption (mA) 50 mA (24V), 12 mA (240) ­Consumption (VA) - 3.5 VA Input Circuit Test Voltage 4 kV 4 kV Switch ON Response Time 100 ms 100 ms Reset Time Between 2 Cycles 100 ms 100 ms Repeat Accuracy with 0.85 - 1.1 Un 2% 2% Weight 0.130, .28 lbs. 0.130, .28 lbs. Approval & Standards VDE 0106, VDE 0110, EN 50001, EN 50002, CSA C 22.2 N° 14, UL 508, IEC 255.5
For ambient conditions data see page 10-24, Table 2. The relays have a green LED that lights when the relay is energized (flashing during the timing) and a red LED that
lights when the output contact is made.
10-20
Control Catalog
Rev. 8/15
Prices and data subject to change without notice
Logic Control
Section 10
IEC Electronic Timers
Multivoltage Electronic Timers
Technical Data
NMRDV Delayed OFF Timer
Electronic relay whose output contact instantly connects when supply voltage is applied to terminals A1-A2. It disconnects with an adjustable delay from the moment the relay loses supply voltage.There are several types depending on the range of timers. There are several types depending on the range of timers.
Product Number NMRDV NMRDV2 NMRDVT
Number of Selectable NO-NC Contacts 121 Output Contacts Rated Insulation Voltage: Ui AC 250V 250V 250V Output Contacts Rated Insulation Voltage: Ui DC 250V 250V 250V Output Contacts Thermal Current Ith 6A 6A 6A Utilization Category AC15 Rated Voltage Ue 125/230V 125/230V 125/230V Utilization Category AC15 Rated Current Ie 2.5/1.3A 2.5/1.3A 2.5/1.3A Utilization Category DC13 Rated Voltage Ue 110/230V 110/230V 110/230V Utilization Category DC13 Rated Current Ie 0.2/0.1A 0.2/0.1A 0.2/0.1A Supply Voltage: AC (with transformer) Un --110-127V, 200-240V, 380-440V Supply Voltage: DC/AC (direct) Un 24-240V 24-240V - Line Voltage Frequency 50/60 Hz 50/60 Hz 50/60 Hz Supply Voltage Tolerance +10/-20 +10/-20 +10/-15 Consumption (mA) 60 (at 24V), 15 (at 240V) 1.5 (at 24V), 5 (at 240V) - Consumption (VA) --3.5 Input Circuit Test Voltage 4 kV 4 kV 4 kV Switch ON Response Time 250 ms Switch OFF Response Time 0.5 - 600s 0.5 - 600s 0.5 - 600s Reset Time Between 2 Cycles 250 ms 250 ms 250 ms Repeat Accuracy with 0.85 - 1.1 Un 5% 5% 5% Weight 0.130, .28 lbs. 0.130, .28 lbs. 0.130, .28 lbs. Approval & Standards VDE 0106, VDE 0110, EN 50002, EN 50042, CSA C 22.2 N° 14, UL 508, IEC 255.5, IEC 947.5.1, UNE 20-119
For ambient conditions data see page 10-24, Table 1. The relays have a green LED that lights when the relay is energized (flashing during the timing) and a red LED that
lights when the output contact is made.
1
For 24VDC = 300 ms.
NMTDV Delayed OFF Through Contact Timer
Electronic relay whose output contact connects instantly when connecting the Y1-Y2 terminals with a voltage-free control. It disconnects with an adjustable delay when the terminals are disconnected. The relay must be supplied with nominal voltage between A1-A2. Loss of supply voltage causes immediate disconnection. It has timing ranges: see drawing. Range selection is made by dip-switches located on the front of the relay. Times are set by front potentiometer controlling an ASIC specially designed for this group of relays. This allows for excellent precision and repeatability features.
Product Number NMTDV
Number of Selectable NO-NC Contacts 1 Output Contacts Rated Insulation Voltage: Ui AC 250V Output Contacts Rated Insulation Voltage: Ui DC 250V Output Contacts Thermal Current Ith 6A Utilization Category AC15 Rated Voltage Ue 125/230V Utilization Category AC15 Rated Current Ie 2.5/1.3A Utilization Category DC13 Rated Voltage Ue 110/230V Utilization Category DC13 Rated Current Ie 0.2/0.1A Supply Voltage: AC (with transformer) Un ­Supply Voltage: DC/AC (direct) Un 24-240V Line Voltage Frequency 50/60 Hz Supply Voltage Tolerance +10/-20 Consumption (mA) 60 (at 24V), 1.5 (at 240V) Consumption (VA) ­Input Circuit Test Voltage 4 kV Switch ON Response Time 100 ms Switch OFF Response Time 0.06 sec. - 100 hrs. Reset Time Between 2 Cycles 100 ms Repeat Accuracy with 0.85 - 1.1 Un 2% Voltage at Open Y1 - Y2 Control Terminals 1V DC Initial Current Through Control Contact 15 mA Permanent Current Through Control Contact 1 mA Weight 0.120, .26 lbs. Approval & Standards VDE 0106, VDE 0110, EN 50001, EN 50002, CSA C 22.2 N° 14, UL 508, IEC 255.5
For ambient conditions data see page 10-24, Table 2. The relays have a green LED that lights when the relay is energized (flashing during the timing) and a red LED that
lights when the output contact is made.
1
250 ms
1
250 ms
1
Rev. 8/15
Prices and data subject to change without notice
Control Catalog
10-21
Loading...