GE - General Electric E2000 Miniature Circuit Breakers Accessories Catalog

Miniature Circuit Breakers
E2000 Miniature Circuit Breakers
Applications
—Commercial —Industrial
Features
—Common for all MCBs —Can be coupled on both sides of MCBs —Gold contact version available for low current and low
voltage applications —Stack up to four CA on left and right sides —Permits the pass-through of busbars, pin and fork, top and
bottom, by changing the position of the base of the auxiliaries
Performance
Change-over contacts 1 Form C Rate current In (A) 5 Rated voltage AC Un (V) 240 Electrical endurance 10000 Terminal capacity flexible/rigid cable (mm2) 2.5 Weight (g) 70
Section 7
Functions
Auxiliary contacts are units to be added on to protection devices. They allow information about the status of the protection device to be monitored from a distance.
Auxiliary contact CA H (function H) reports the OPEN/CLOSED status. CA S/H or CA S/H G act as either an auxiliary contact (function H)
or a signal contact (function S). The user can set the function at the time of installation. When used as a signal contact, it reports information about the automatic tripping of the protection devices. A test button on the front simulates functions H or S. There are also a reset button for the contacts (function S) and a tripping signal (function S).
Approval/Marking
—CE —cURus —CEBEC —KEMA EUR
Series CA
Function Std. Pack Product No. GO-135VB
H1CA H $47.00
S/H 1 CA S/H $59.00 S/H (gold contacts) 1 CA S/H G $59.00 Padlocking Bracket 25 KS $12.00
List Price
Coupling
Busbar pass-through
Stack-on
1/2 mod.
H
S
7-12
Control Catalog
Rev. 4/16
Prices and data subject to change without notice
Miniature Circuit Breakers
E2000 Miniature Circuit Breakers
Series CB Auxiliary Switch and Bell Alarm
Applications
—Commercial —Industrial
Features
—Common for all MCBs —Can be coupled on both sides of MCBs —There are two change-over contacts – the upper one features
changeable function S/H
—CB SH/HH-R couples to the right side of the protection devices;
CB SH/HH-L couple to the left —No stack-on possibilities (only one auxiliary) —No busbar pass-through facilities
Performance
Change-over contacts 2 Form C Rate current In (A) 5 Rated voltage AC Un (V) 240 Electrical endurance 10000 Terminal capacity flexible/rigid cable (mm2) 2.5 Weight (g) 80
Section 7
Functions
The bottom auxiliary contact (function H) reports the OPEN/ CLOSED status.
The top auxiliary contact can act as either an auxiliary contact (function
H) or a signal contact (function S). The user can set the function at the time of installation. When used as a signal contact, it reports information about the automatic tripping of the protection devices.
A test button on the front simulates functions H or S. There are also a reset button for the contacts (function S) and a tripping signal (function S).
Approval/Marking
—cURus
Series CB
Function Coupling Std. Pack Product No. GO-135VB
SH/HH Right 1 CB SH/HH-R $87.00 SH/HH Left 1 CB SH/HH-R $87.00
List Price
Coupling right
Coupling left
1/2 mod.
HS
Rev. 4/16
Prices and data subject to change without notice
Control Catalog
7-13