Lighting Contactors
4.62
.50
1.38
1.63
35.1
12.7
1.38
35.1
1.00
8.00
254
41.4
25.4
203.2
10.00
1.0
25.4
117.3
1.13
1.00
1.75
1.75
44.4
44.4
A
B
A
K.O.'s SAME TOP & BOTTOM
28.7
25.4
ÿ.25
ÿ6.4
HOLE FOR PADLOCK
3 POINT MTG.
FOR #10 SCREWS
A
A
(BACK)
(BOTH
SIDES)
ACOMBINATION KNOCKOUT FOR
1/2 or 3/4-INCH CONDUIT
COMBINATION KNOCKOUT FOR
3/4 or 1-INCH CONDUIT
B
10.00
D
4.8
.19
3.5
88.9
3.5
88.9
1.5
38.1
COMBINATION KNOCKOUT FOR
1/2, 1 1/4 OR 1 1/2 INCH CONDUI
T
C
254.0
5.00
127.0
203.2
8.00
C (PART 1 ONLY)
13.54
343.9
10.00
254.0
16.75
425.5
17.50
444.5
6.50
165.1
7.67
194.7
2.50
63.5
2.00
50.8
7.00
177.8
1.75
44.5
1.75
44.5
15.54
394.7
PILOT LIGHTS
PUSH BUTTONS
HOLE FOR PADLOCK
HOLE FOR PADLOCK
4 PT. MTG FOR
1/4-20 SCREWS
C*
B*
A
C
B
A
A- COMBINATION KNOCKOUT FOR
1/2 OR 3/4 INCH CONDUIT
B- COMBINATION KNOCKOUT FOR
3/4 OR 1 INCH CONDUIT
C- COMBINATION KNOCKOUT FOR
1/2, 1-1/4 OR 1-1/2 INCH CONDUIT
* NOTE : KNOCKOUTS REVERSED ON BOTTOM
CR460 Series Lighting Contactors – Project Submittal Form
Item No. Proposition No.
CR460 Series lighting contactors feature:
—A modular design that permits fast, on-site configuration
—2-12 power poles that latch easily onto the base as either
NO or NC and that can be added at any time
—30 amp rating
—Snap-in auxiliary contacts
Main Power Pole Ratings
Maximum AC Voltage and Amp Ratings
Load Type Amps Continuous 1 Phase 3 Phase
Ballast 30 347 Vac 600 Vac
General Use 30 600 Vac 600 Vac
Tungsten 20 277 Vac 480 Vac
AC Resistive 30 600 Vac 600 Vac
Power pole
configuration Electrically Held Contactor Mechanically Held Contactor
NO NC Standard Type 1 Enclosure Oversized Type 1 Enclosure Standard Type 1 Enclosure Oversized Type 1 Enclosure
2 0 ❐ CR463L20A*A10A0 ❐ CR463L20A*A10AA ❐ CR463M20##A10A0 ❐ CR463M20##A10AA
3 0 ❐ CR463L30A*A10A0 ❐ CR463L30A*A10AA ❐ CR463M30##A10A0 ❐ CR463M30##A10AA
4 0 ❐ CR463L40A*A10A0 ❐ CR463L40A*A10AA ❐ CR463M40##A10A0 ❐ CR463M40##A10AA
6 0 ❐ CR463L60A*A10A0 ❐ CR463L60A*A10AA ❐ CR463M60##A10A0 ❐ CR463M60##A10AA
8 0 ❐ CR463L80A*A10A0 ❐ CR463L80A*A10AA ❐ CR463M80##A10A0 ❐ CR463M80##A10AA
10 0 ❐ CR463LB0A*A10A0 ❐ CR463LB0A*A10AA ❐ CR463MB0##A10A0 ❐ CR463MB0##A10AA
12 0 ❐ CR463LD0A*A10A0 ❐ CR463LD0A*A10AA ❐ CR463MD0##A10A0 ❐ CR463MD0##A10AA
___ ___ __________________ __________________ __________________ __________________
Maximum Horsepower Rating (Normal Starting Duty)
1 Pole Single Phase 3 Poles, Three Phase
Volts 110-120V 220-240V 200-208V 220-240V 440-480V 550-600V
HP 1 2 3 5 10 15
* 60Hz Coil Voltage (✓) for Electrically Held
115- 200- 230- 460- 575-
24V 120V 208V 240V 277V 488V 600V
❐ C ❐ J ❐ L ❐ S ❐ T ❐ U ❐ Y
Extended description (if any):
—Common components for both electrically and mechanically
held versions
—Continuously rated, interchangeable coils
—Finger-safe terminals
## Control Module (✓) for Mechanically Held
Control Volts 115-120V 277V 115-120V 277V
24-28V ❐ BJ ❐ BN ❐ MJ ❐ MN
110-120V ❐ CJ ❐ CN ❐ NJ ❐ NN
200-277V ❐ DJ ❐ PN ❐ PJ ❐ PN
2-wire Control 3-wire Control
Coil Voltage Coil Voltage
Section 3
Type 1, Standard Enclosure Type 1, Oversized Enclosure
Control Catalog
3-8
Rev. 8/15
Prices and data subject to
change without notice