EMA Full Voltage Power Devices
N
ection 1
S
NEMA Rated Full Voltage Starters - Magnetic
CR387, CR487 Mag-Break Magnetic Starters
Nonreversing, Combination NEMA Type 1, 3R, 12, 4/4X NEMA Sizes 0-5, Mag-Break Circuit Breaker Type 600 Volts Maximum 50/60 Hertz
List Price includes a holding interlock, pressure terminals for the line and load connections, plus a 3-leg block type overload relay (manual reset). All enclosures include external reset. Three heaters should be ordered as separate items. See pages 1-153 to 1-159 for selection.
CR387/487
Voltage NEMA Maximum Amp Rating Number Number Price Number Price Number Price (60Hz) Size Horsepower Rating (Amps) CR CR CR CR
2
00-208 01 18 7 387BT08MB1AAAAA 487B608MB1AAAAA 487B208MB1AAAAA 487B408MB1AAAAA
200-208 03 18 15 387BT08MC1AAAAA 487B608MC1AAAAA 487B208MC1AAAAA 487B408MC1AAAAA
00-208 15 27 25 387CT08ME1AAAAA 487C608ME1AAAAA 487C208ME1AAAAA 487C408ME1AAAAA
2 2
00-208 1 7 1/2 27 40 387CT08MG1AAAAA 487C608MG1AAAAA 487C208MG1AAAAA 487C408MG1AAAAA
200-208 2 10 45 50 387DT08MH1AAAAA 487D608MH1AAAAA 487D208MH1AAAAA 487D408MH1AAAAA
00-208 3 15 90 70 487E108MK1AAAAA 487E608MK1AAAAA 487E208MK1AAAAA 487E408MK1AAAAA
2 2
00-208 3 20 90 80 487E108ML1AAAAA 487E608ML1AAAAA 487E208ML1AAAAA 487E408ML1AAAAA
200-208 3 25 90 100 487E108MN1AAAAA 487E608MN1AAAAA 487E208MN1AAAAA 487E408MN1AAAAA
00-208 4 30 135 125 487F108MQ1AAAAA 487F608MQ1AAAAA 487F208MQ1AAAAA 487F408MQ1AAAAA
2 2
00-208 4 40 135 150 487F108MR1AAAAA 487F608MR1AAAAA 487F208MR1AAAAA 487F408MR1AAAAA
200-208 5 75 270 400 387G123CAAA 387G623CAAA 387G223CAUA 387G423CAAA
30-240 0 1/2 18 3 387BT03MA1AAAAA 487B603MA1AAAAA 487B203MA1AAAAA 487B403MA1AAAAA
2 2
30-240 01 18 7 387BT03MB1AAAAA 487B603MB1AAAAA 487B203MB1AAAAA 487B403MB1AAAAA
230-240 03 18 15 387BT03MC1AAAAA 487B603MC1AAAAA 487B203MC1AAAAA 487B403MC1AAAAA
30-240 15 27 25 387CT03ME1AAAAA 487C603ME1AAAAA 487C203ME1AAAAA 487C403ME1AAAAA
2 2
30-240 1 7 1/2 27 30 387CT03MF1AAAAA 487C603MF1AAAAA 487C203MF1AAAAA 487C403MF1AAAAA
230-240 2 10 45 40 387DT03MG1AAAAA 487D603MG1AAAAA 487D203MG1AAAAA 487D403MG1AAAAA
30-240 2 15 45 60 387DT03MJ1AAAAA 487D603MJ1AAAAA 487D203MJ1AAAAA 487D403MJ1AAAAA
2 2
30-240 3 20 90 70 487E103MK1AAAAA 487E603MK1AAAAA 487E203MK1AAAAA 487E403MK1AAAAA
230-240 3 25 90 90 487E103MM1AAAAA 487E603MM1AAAAA 487E203MM1AAAAA 487E403MM1AAAAA
30-240 3 30 90 100 487E103MN1AAAAA 487E603MN1AAAAA 487E203MN1AAAAA 487E403MN1AAAAA
2 2
30-240 4 40 135 150 487F103MR1AAAAA 487F603MR1AAAAA 487F203MR1AAAAA 487F403MR1AAAAA
230-240 4 50 135 175 487F103MS1AAAAA 487F603MS1AAAAA 487F203MS1AAAAA 487F403MS1AAAAA
30-240 5 100 270 400 387G103CAAA 387G603CAAA 387G203CAUA 387G403CAAA
2 4
60-480 01 18 3 387BT04MA1AAAAA 487B604MA1AAAAA 487B204MA1AAAAA 487B404MA1AAAAA
460-480 03 18 7 387BT04MB1AAAAA 487B604MB1AAAAA 487B204MB1AAAAA 487B404MB1AAAAA
60-480 05 18 15 387BT04MC1AAAAA 487B604MC1AAAAA 487B204MC1AAAAA 487B404MC1AAAAA
4 4
60-480 1 7 1/2 27 15 387CT04MC1AAAAA 487C604MC1AAAAA 487C204MC1AAAAA 487C404MC1AAAAA
460-480 1 10 27 20 387CT04MD1AAAAA 487C604MD1AAAAA 487C204MD1AAAAA 487C404MD1AAAAA
60-480 2 15 45 30 387DT04MF1AAAAA 487D604MF1AAAAA 487D204MF1AAAAA 487D404MF1AAAAA
4 4
60-480 2 20 45 40 387DT04MG1AAAAA 487D604MG1AAAAA 487D204MG1AAAAA 487D404MG1AAAAA
460-480 2 25 45 50 387DT04MH1AAAAA 487D604MH1AAAAA 487D204MH1AAAAA 487D404MH1AAAAA
60-480 3 30 90 50 487E104MH1AAAAA 487E604MH1AAAAA 487E204MH1AAAAA 487E404MH1AAAAA
4 4
60-480 3 40 90 70 487E104MK1AAAAA 487E604MK1AAAAA 487E204MK1AAAAA 487E404MK1AAAAA
460-480 3 50 90 90 487E104MM1AAAAA 487E604MM1AAAAA 487E204MM1AAAAA 487E404MM1AAAAA
60-480 4 60 135 100 487F104MN1AAAAA 487F604MN1AAAAA 487F204MN1AAAAA 487F404MN1AAAAA
4 4
60-480 4 75 135 125 487F104MQ1AAAAA 487F604MQ1AAAAA 487F204MQ1AAAAA 487F404MQ1AAAAA
460-480 4 100 135 175 487F104MS1AAAAA 487F604MS1AAAAA 487F204MS1AAAAA 487F404MS1AAAAA
60-480 5 200 270 400 387G104CAAA 387G604CAAA 387G204CAUA 387G404CAAA
4 5
75-600 01 18 3 387BT05MA1AAAAA 487B605MA1AAAAA 487B205MA1AAAAA 487B405MA1AAAAA
575-600 03 18 7 387BT05MB1AAAAA 487B605MB1AAAAA 487B205MB1AAAAA 487B405MB1AAAAA
75-600 05 18 15 387BT05MC1AAAAA 487B605MC1AAAAA 487B205MC1AAAAA 487B405MC1AAAAA
5 5
75-600 1 10 27 15 387CT05MC1AAAAA 487C605MC1AAAAA 487C205MC1AAAAA 487C405MC1AAAAA
575-600 2 15 45 25 387DT05ME1AAAAA 487D605ME1AAAAA 487D205ME1AAAAA 487D405ME1AAAAA
75-600 2 20 45 30 387DT05MF1AAAAA 487D605MF1AAAAA 487D205MF1AAAAA 487D405MF1AAAAA
5 5
75-600 2 25 45 40 387DT05MG1AAAAA 487D605MG1AAAAA 487D205MG1AAAAA 487D405MG1AAAAA
575-600 3 30 90 40 487E105MG1AAAAA 487E605MG1AAAAA 487E205MG1AAAAA 487E405MG1AAAAA
75-600 3 40 90 60 487E105MJ1AAAAA 487E605MJ1AAAAA 487E205MJ1AAAAA 487E405MJ1AAAAA
5 5
75-600 3 50 90 70 487E105MK1AAAAA 487E605MK1AAAAA 487E205MK1AAAAA 487E405MK1AAAAA
575-600 4 60 135 80 487F105ML1AAAAA 487F605ML1AAAAA 487F205ML1AAAAA 487F405ML1AAAAA
75-600 4 75 135 100 487F105MN1AAAAA 487F605MN1AAAAA 487F205MN1AAAAA 487F405MN1AAAAA
5 5
75-600 4 100 135 150 487F105MR1AAAAA 487F605MR1AAAAA 487F205MR1AAAAA 487F405MR1AAAAA
575-600 5 125 270 400 387G105BAAA 387G605BAAA 387G205BAUA 387G405BAAA
75-600 5 200 270 400 387G105CAAA 387G605CAAA 387G205CAUA 387G405CAAA
5
Mag-Break Circuit Breaker Type
Continuous CB Product Product Product Product
NEMA Type 1 NEMA Type 3R NEMA Type 12 NEMA Type 4/4X
• NEMA Size 5 starters with 115-120Volt, 60 Hertz coil for separate control are available at listed prices. To order, replace Digits 8 and 9 of listed Product Numbers with 02. Example: --CR487C208MG1AAAAA with 115-120 Volt, 60 Hertz coil for separate control becomes CR487C202MG1AAAAA.
• Motor full load current should not exceed continuous ampere rating of starter.
ev. 8/15
R
and data subject to
Contr
ol Catalog
1-51
EMA Full Voltage Power Devices
00 0 1 2 3 4 5 6
4
Indicating Light
1
4a
One (R
ed Only)
2
1
4b
One (Specif
y Red or Green)
(HEAVY-DUTY, CR104P)
Any
4c
Two (Includes 1 NC Auxiliary Contact)
4
(HE
AVY-DUTY, CR104P)
Any
4d
One Push-To-Test and/or Transformer Type (Red or Green)
Any
4e
Two Push-To-Test (Includes 1 NC Auxiliary Contact) and/or Transformer Type
4
Any
5
Push Buttons
5a
FORW
ARD-STOP-REVERSE
Any
5b
HIGH-LOW-OFF
Any
5c
FAST-SLOW-STOP
Any
5d
HIGH-LOW Push Button and
H-O-A Selector Switch
Any
5e
Single Push Button, Unwired
(Specify Marking)
5
Any
5f
Single Illuminated Push Button,
Unwir
ed (Specify Marking)
5
Any
6
Selector S
witches
6a
LOW-OFF-HIGH
Any
6b
SLOW-OFF-FAST
Any
6c
FORWARD-OFF-REVERSE
Any
6d
LOW-HIGH and HAND-OFF-AUTO
Any
6e
HAND-OFF-AUTO
Any
Single Selector Switch Maintained
(Specify Marking and Positions)
(Specify Two or Three Positions)
5
Any
K
ey Operated Maintained (Specify
Marking and Key-Removal Positions)
(Specify Two or Three Positions)
5
Any
6h
Nonstandar
d Markings
Any
6g
N
ote: For indicating light modifications on CR309-311 & CR390, see p. 1-124.
1
One indicating light: W
ired in parallel with operating coil.
Two indicating lights:
Red is wired in parallel with operating coil, green is wired through an auxiliary contact.
Pilot
Devices
Mounted In
Cov
er or
Flange of
CR306 CR307 CR308
CR387 CR407 CR408 CR487
Pilot
Devices
Mounted In
Cover or
Flange of
CR309 CR310 CR311 CR390 CR410 CR411 CR490
6f
Starter NEMA Size
Type of
Installation/
Starters
Item
No. Modifications
Enclosure
Type
F
actory-installed field modification kit for sizes 00-4 and size 5 without CPT. Not available in NEMA Size 00. Use Size 0 starter and modification. Maximum of three additional auxiliary contacts available on size 0-1. Specify CR104P operator and contact block by product number.
N
ection 1
S
NEMA Rated Full Voltage Starters - Magnetic
CR306, CR307, CR308, CR309, CR310, CR311, CR387, CR390, CR407, CR408, CR410, CR411, CR487, CR490 Magnetic Starters
F
actory-Installed Modifications
Starter Modifications—Factory Installed
The general information at the top of page 1-124 regarding factory-installed modifications, also applies to those listed in the table below.
Control Circuit Fusing
Per the NEC and UL508 Section 18.2 - Control Circuit Fuses must be used when the branch circuit protective device rating is too large to serve as protection for the control circuit. This depends on the control wire size and whether all control circuit wires are within the enclosure. See table below:
Provide supplemental control circuit protection if control circuits with wires longer
than
12 inches are connected to branch circuit protection exceeding the ratings below
Control Maximum Branch Circuit Maximum Supplemental Circuit Protection Rating (Amperes) Control Circuit
Wire Size Conductors Conductors Protection Rating
(A
WG) within Enclosure outside Enclosure (Amperes)
22 12 33 20 20 55 18 25 77 16 40 10 10 14 100 45 20 12 120 60 25
ev. 8/15
R
and data subject to
The
factory must provide this protection, if the circuit provided by the factory requires the fuses. The factory will provide control circuit fuses in enclosed starters and contactors with pilot devices, control relays or other control components that are factory wired; when used with line voltage control; when the size listed below is being supplied.
Non-combination starters (CR305, CR306, CR309, CR385, CR386)
Size 4 and above
Combination starters
Size 0-3 with Mag-Break Protector Size 3 with: —Circuit Breaker greater than 100 amps, or —Fuse Clips greater than 100 amps, or Size 4 and above with any circuit breakers, circuit protector or fuse clips.
Control Circuit fuses (Modification 9) must be added to the enclosed starter or contactor pricing.
All CPTs will be supplied with primary fuses. CPTs without primary fuses are no longer available.
When control circuit fuses are not factory supplied, customer provided wiring or branch circuit protection sizing to these contactors and starters may still require that the customer/installer add the fusing in the field. It will be the customer/installer’s responsibility to ensure code compliance under these conditions.