GE - General Electric AF-650GP Specification Sheet

AF-650GP™General Purpose Drive
Standard Specifications
Section 15Drives
Environmental Conditions
Enclosures IP20 Chassis, IP00 Chassis, IP21/NEMA 1, IP55/NEMA 12,
Installation Location Do not install in locations where product could be
Storage Temperature -25° to 65°C Ambient Temperature -10° to +50°C (24 hour average max of 45°C) Ambient Humidity 5 to 95% RH (non-condensing) Vibration 1.0g Cooling Method Fan Cooled all ratings. Fan Control Auto, 50% level,
IP54/NEMA 12, IP66/NEMA 4
exposed to dust, corrosive gas, inflammable gas, oil mist, vapor, water drops or direct sunlight. There must be no salt in the atmosphere. Condensation must not be caused by sudden changes in temperature. For use at altitudes of 3280 ft . (1000M) or less without derating.
75% level, 100% level adjustable
Standards
Approvals CE, UL, cUL , and C-Tick
Suitable for use on a circuit capable of delivering not more than 100,000 rms symmetrical amperes for 230V and 460V.
Input Power Supply
Rated Input AC Voltage 200-240 Vac, 3-phase, 50-60 Hz, +/- 10% V
Maximum Voltage Imbalance 3% of rated supply voltage True Power Factor > 0.9 nominal at rated load Displacement Power Factor > 0.98 Switching on input power supply Maximum twice/minute up to 10HP, Maximum
Environment according to EN60664-1 Overvoltage category III/pollution degree 2
380-500 Vac, 3-phase, 50-60 Hz, +/- 10% V 525-600 Vac, 3-phase, 50-60Hz, +/- 10% V 525-690 Vac, 3-phase, 50-60 Hz, +/- 10% V
once/minute above 10HP
Output
Rated Output Voltage 0-100% of supply voltage Output Frequency 0-1000 Hz; 0-800Hz for 460V above 100HP and
Switching on output Unlimited Accel/Decel Times 0.01-3600 seconds Control Method Sinusoidal P WM Control (V/Hz, Avd. Vector Control,
525/600/690 V above 100HP
Sensorless Vector, and Flux Vector with motor feedback)
Control
Starting Torque 160% starting torque for 1 minute (constant torque),
Carrier Frequency (Motor Noise) Selectable - 1, 1.5, 2, 2.5, 3, 3.5, 4, 5, 6, 7, 8, 10,
Torque Boost Selectable by up to 5 individual V/Hz settings in V/Hz
Acceleration/Deceleration Time 0.01-3600 seconds (4 acceleration and deceleration
Data Protection Password Protection for Quick Menu or Main Menu,
Pattern Operation Settings via Built-In Logic Controller Sequencer Jump Frequency Control 4 jump (or skip) frequencies via parameter set to avoid
Slip Compensation Maintains motor at constant speed with load fluctuations Torque Limit Control Output torque can be controlled within a range of 0.0
8 Preset Speeds 8 programmable preset speeds selectable by 3 digital
Trim Reference Setting Available for speed reference offset via potentiometer,
DC Injection Braking Starting frequency: 0.0-1000 Hz, 0-800Hz for 460V
Jogging Operation Operation via On key or digital input (Fwd or Rev) Auto-Restart After Power Failure Restarts the drive without stopping after instantaneous
Energy Savings Controls output voltage to minimize motor loss during
Start Mode Function This functionality smoothly catches a spinning motor
110% starting torque for 1 minute (variable torque)
12, 14, 16 kHz
Mode or by 0 - 300% setting of Torque Boost parameter in Adv. Vector Mode
times are selectable via digital inputs. Acceleration and deceleration patterns can be selected from linear or S-curve)
0-9999.
mechanical vibration
to 160% (0.1 and steps)
inputs
voltage input, or current input
above 100HP and 525-690 V above 50HP Braking time: 0.0-60.0 seconds Braking level: 0-100% of rated current
power failure
constant speed operation
Logic Controller (LC) Sequencer
Logic Controller Events Up to 37 types of Programmable Events Comparators Array of 6 Comparators Timers Array of 8 Timers, adjustable from 0.0 to 3600 sec Logic Rules Array of 6 Boolean Logic Rules Logic Controller States Array of 20 Logic Controller Action States
Process Controller (PID)
Process CL Feedback Select Up to 2 references. Selectable - No function, Motor
Process PID Control Normal or Inverse Process PID Anti Windup Disabled or enabled Process PID Start Speed 0.0-200 Hz Process PID Proportional Gain 0.00-10.00 Process PID Integral Time 0.1 - 10000.0 ms Process PID Differential Time 0.0 - 10 s Process PID Differential Gain 1.0-50.00 Process PID Feed Forward Factor 0-500% On Reference Bandwidth 0-200%
Feedback, Separate Encoder, Encoder Option Module, or Resolver Option Module
Operation
Operation Method Keypad operation: Hand, Off, Auto
Frequency Reference Signal Left or Right Arrow buttons on keypad in Manual Mode
References Up to 3 Input References can be selected from Analog
Input Signals 6 - Digital Inputs, 24 Vdc PNP or NPN
Digital Input: Programmable for Start/Stop,
Forward/Reverse, Jog Timer operation: Stop after predetermined time frame Built-in RS-485 Modbus RTU USB Port for programming drive with optional PC Software
Speed Potentiometer: 0 to +10 Vdc, 10 to 0 Vdc 0-10Vdc analog input 0/4-20ma analog input
Input #1 or #2, Frequency Input #1 or #2, Network, or Potentiometer
1 - Safe Stop Digital Input suitable for category 3
installations to meet EN-954-1 2 - Pulse Inputs rated to 110kHz or 1 - Pulse Input and
1 - Encoder Input 24 Vdc rated to 4096 PPR 2 - Analog Inputs -10 to +10V scalable or 0/4 to 20 mA
scalable Digital Input Settings: No Operation Reset after drive trip or alarm Drive at stop with no holding current Quick Stop according to Quick Stop Decel Time 1 Stop on input going low Start Maintained Start arfter signal applied for Minimum of 2ms Reversing Start Reverse Enable Start Forward only Enable Start Reverse only Jog Multi-Step Frequency selection (1 to 8 Steps) Hold Drive Frequency Hold Reference Speed Up; activated by Hold Drive Frequency
or Hold Reference Slow Down; activated by Hold Drive Frequency
or Hold Reference Drive Parameter Setup Select 1-4 Precise Start or Stop; Activated when drive parameter
precise start or stop function is selected Catch Up or Slow Down; Activated by signal to add to
or subtract from input reference to control speed Pulse Input selectable from 100 - 110000Hz Accel / Decel Time select. Set Input to Accel / Decel
Times 1 to 4 Digital Potentiometer Input Increase or Decrease Mechanical Brake Feedback
Rev. 8/15
Prices and data subject to change without notice
Control Catalog
15-27
AF-650GP™General Purpose Drive
Standard Specifications
Section 15Drives
Operation (continued)
Output Signals 2 - Digital Outputs 24 Vdc (Digital Outputs are used in
Protective Functions Line Phase Loss
place of 2 of the Digital Inputs) 2 - Form C Relays rated to 2A at 240 Vac 1 - Analog Output 0/4 to 20mA Relay Output Settings: No Operation Control Ready Drive Ready Drive Ready in Remote Standby No Drive Warnings Drive Running Drive Running No Drive Warnings Drive Running on Remote Alarm Alarm or Warning At Torque Limit Out of Current Range Below Current Above Current Out of Speed Range Below Speed Above Speed Out of Feedback Range Below Feedback Above Feedback Thermal Overload Warning Reverse Bus OK Torque Limit and Stopped Brake and no Warning Brake Ready and No Faults Brake Chopper Fault External Interlock Out of External Reference Range Below External Reference Above External Reference Fieldbus Controlling Drive No Alarm Running in Reverse Local Mode Active Remote Mode Active Start Command Active Hand Mode Active Auto Mode Active
DC Overvoltage DC Undervoltage Drive Overload Motor Overtemperature Motor Thermistor Overtemperature Torque Limit Overcurrent Ground Fault Short Circuit Control Word Timeout Brake Resistor Short-Circuited Brake Chopper Short-Circuited Brake Check DC Link Voltage High DC Link Voltage Low Internal Fan Fault External Fan Fault Power Board Overtemperature Missing U Phase Missing V Phase Missing W Phase Internal Fault Control Voltage Fault Auto Tune Check - Wrong Motor Parameters Auto Tune Low Inom - Motor current is too low Current Limit Mechanical Brake Low Drive Initialized to Default Value Keypad Error No Motor Soft Charge Fault Auto Tuning Fault Serial Comms Bus Fault Hardware Mismatch Speed Limit
Keypad
Keypad Features LCD Display with 6 Alpha-numeric lines. Multi-Language
Keypad Keys Status - shows status of drive
Password 2 Level Password Protection Alternate Motor Parameters Up to 4 Separate complete parameter set-ups are
Graphical Trending Trend Speed, Power, Frequency or any value
Support
Hot Pluggable, Remote Mount Option, and CopyCat
Feature, IP65 rating when remote mounted on enclosure
LED's - Green - drive is on, Yellow - indicates a warning,
Red - indicates an alarm, Amber - Indicates active Menu keys and H-O-A keys
Quick Menu - Enters Quick Start, Parameter Data Check,
or Trending Modes Main Menu - Used for programming all drive parameters Alarm Log - Used to display Alarm list Back - Reverts to previous step or layer in parameter structure Cancel - Used to cancel last change or command Info - Displays information about a command,
parameter, or function in any display. Hand/Off/Auto - Used to control drive locally or put
drive in remote mode Reset - Used to reset Warnings or Alarms
available
programmed in status display
RS485 Modbus RTU Serial Communications
Physical Level: EIA/RS485 Transmission Distance: 1640 ft (500m) Node Address: 32 Transmission Speed: 2400, 4800, 9600, 19200, 38400,or 115200 (bits/s) Transmission Mode: Half Duplex Transmission Protocol Modbus RTU Character Code: Binary Character Length: 8 Bits Error Check: CRC
Mounting Clearance
All AF-650GP™drives can be mounted Side-by-Side
without spacing. For all drives rated 100HP or below allow 3.4 inches
(100mm) free space above and below. For all drives rated 125HP and above allow 8.9 inches
(225mm) free space above and below.
15-28
Control Catalog
Rev. 8/15
Prices and data subject to change without notice