TU
COMPACT LOAD CELL FOR TENSION/COMPRESSION
APPLICATIONS
MECHANICAL DIMENSIONS
Main features
• Range of measurement: from 50 to 1000 kg
• Accuracy class: 0,2%
• All stainless steel construction
• Corrosion resistant
• Grade of protection: IP67 ( norme DIN 40050)
• Compact size
The TU range of load cells are designed for the
measurement of static or dynamic loads in compression
(output signal: negative) or traction (output signal: positive).
All the transducers are calibrated as load cells in units of
mass (Kg). The TU series is supplied for nominal loads from
50Kg to 1t.
This model has an IP67 protection degree so it can be used
in aggressive atmospheres often found in the chemical
industries. The transducer body is machined from a single
piece of stainless steel with no welding. This means that it is
highly resistant to mechanical shock and vibration.
The compact size means that these cells can be placed in
positions that are difficult to acess and where little space is
available.
Dimensions mm. (± 0,1)
* Recommended torque
** UNI 5931 screws of resistance class 10.9 according to UNI 3740
TECHNICAL DATA
0,2%
50...1000 kg
2mV/V
<± 0,2% FSO
< ± 0,2% FSO
< ± 0,06% FSO
< ± 1% FSO
< ± 0,01% FSO°C
< ± 0,01% FSO°C
350 Ohm
350 Ohm
> 10 GOhm
10 V
15 V
-10...+50°C
-20...+60°C
-30...+80°C
130% Ln
100% Ln
150% Ln
> 300% Ln
< 0,2 mm
IP67
4x0,25 / 5 m.
Stainless steel
Accuracy
Nominal full scale load (Ln)
Nominal output at FSO
Output tolerance at Ln
Combined errors: Non linearity
Histeresis, Repeatibility
Creep (after 30 min. at Ln)
Zero load out of balance signal
Thermal drift in Sensitivity
compensated Zero
range Calibration
Nominal input resistance
Nominal output resistance
Isolation resistance
Nominal supply voltage
Maximum supply voltage
Compensated temperature range
Maximum temperature range
Storage temperature range
Permitted static load
Permitted dinamic load
Maximum applicable load
Rupture load
Maximum elastic deformation at Ln
Grade of protection (DIN40050)
Electr. connections screened cable
Elastic element material
4 Holes M5
SCREENED CABLE
LOAD
INTRODUCTION
DIRECTION
BALL R60
M12 NUT (UNI5589)
(CH 19 - h 7)
equidistants

DTS_TU_0709_ENG
GEFRAN spa reserves the right to make any kind of design or functional modification at any moment without prior notice.
ELECTRICAL CONNECTIONS
CONVERSION TABLE
ORDER CODE
Ex.: TU - K5D
TU load cell, measurement range 0 - 50 kg.
If request, it is possible to supply models with non-standard
mechanical and/or electrical
features.
Load cell TU
0 - 200 K2C
MEASUREMENT RANGE (kg)
0 - 50
0 - 100
K5D
K1C
Cells connected in parallel
In systems that use several cells, the parallel
connection automatically sums the loads on each
individual cell.
Using this method of measurement, the maximum load
will be the sum of the loads on the individual cells and
the sensitivity will be the average value of these cells.
It is important that the user ensures that no cell is
stessed beyond its maximum rating under any load
condition.
Kg
1
0.102
0.454
N
9.807
1
4.448
Lb
2.205
0.225
1
OPTIONAL ACCESSORIES
* The screen is isolated from the transducer body.
It is recommended that the ground is connected at the
instrument end.
Red
SIGNAL
SIGNAL
EXCITATION
EXCITATION
SHIELD
CABLE EXIT
Yellow or Black
White
Green
Yellow-Green
Flange for applying suspended loads FLA 703
Ball joint SND022
APPLICATION NOTES
Mounting with double joint and flange for suspended loads
Wall mounting with ball joint.
0 - 500 K5C
0 - 1000 K1M
4x0.25 Screened cable
Shield
White
Green
Joint
Red
Yellow
Red
Yellow or Black
White
Green
Yellow-Green
Red
Yellow or Black
White
Green
Yellow-Green
Yellow-Green
Red
Yellow or Black
White
Green
SHUNT BOX
Locknut
NO LOAD ON
THIS SURFACE
NO LOAD ON
THIS SURFACE
Joint
Locknut
Joint