COMPACT LOAD CELL FOR TENSION/COMPRESSION APPLICATIONS
MECHANICAL DIMENSIONS
Main features
• Range of measurement: from 50 to 1000 kg
• Accuracy class: 0,2%
• All stainless steel construction
• Grade of protection: IP67 ( norme DIN 40050)
• Compact size
The TU range of load cells are designed for the measurement of static or dynamic loads in compression (output signal: negative) or traction (output signal: positive). All the transducers are calibrated as load cells in units of mass (Kg). The TU series is supplied for nominal loads from 50Kg to 1t. This model has an IP67 protection degree so it can be used in aggressive atmospheres often found in the chemical industries. The transducer body is machined from a single piece of stainless steel with no welding. This means that it is highly resistant to mechanical shock and vibration. The compact size means that these cells can be placed in positions that are difficult to acess and where little space is available.
Dimensions mm. (± 0,1) * Recommended torque ** UNI 5931 screws of resistance class 10.9 according to UNI 3740
TECHNICAL DATA
0,2%
50...1000 kg 2mV/V
<± 0,2% FSO
< ± 0,2% FSO
< ± 0,06% FSO
< ± 1% FSO
< ± 0,01% FSO°C < ± 0,01% FSO°C
­350 Ohm 350 Ohm
> 10 GOhm
10 V 15 V
-10...+50°C
-20...+60°C
-30...+80°C 130% Ln
100% Ln 150% Ln
> 300% Ln
< 0,2 mm
IP67
4x0,25 / 5 m.
Stainless steel
Accuracy Nominal full scale load (Ln)
Nominal output at FSO Output tolerance at Ln
Combined errors: Non linearity Histeresis, Repeatibility
Creep (after 30 min. at Ln) Zero load out of balance signal Thermal drift in Sensitivity
compensated Zero range Calibration
Nominal input resistance Nominal output resistance Isolation resistance Nominal supply voltage Maximum supply voltage Compensated temperature range Maximum temperature range Storage temperature range Permitted static load Permitted dinamic load Maximum applicable load Rupture load Maximum elastic deformation at Ln Grade of protection (DIN40050) Electr. connections screened cable
Elastic element material
4 Holes M5
SCREENED CABLE
LOAD INTRODUCTION DIRECTION
BALL R60
M12 NUT (UNI5589)
(CH 19 - h 7)
equidistants
DTS_TU_0709_ENG
GEFRAN spa reserves the right to make any kind of design or functional modification at any moment without prior notice.
ELECTRICAL CONNECTIONS
CONVERSION TABLE
ORDER CODE
Ex.: TU - K5D
TU load cell, measurement range 0 - 50 kg.
If request, it is possible to sup­ply models with non-standard mechanical and/or electrical features.
Load cell TU
0 - 200 K2C
MEASUREMENT RANGE (kg)
0 - 50 0 - 100
K5D K1C
Cells connected in parallel
In systems that use several cells, the parallel connection automatically sums the loads on each individual cell. Using this method of measurement, the maximum load will be the sum of the loads on the individual cells and the sensitivity will be the average value of these cells. It is important that the user ensures that no cell is stessed beyond its maximum rating under any load condition.
Kg
1
0.102
0.454
N
9.807 1
4.448
Lb
2.205
0.225 1
OPTIONAL ACCESSORIES
* The screen is isolated from the transducer body. It is recommended that the ground is connected at the instrument end.
Red
SIGNAL
SIGNAL
EXCITATION
EXCITATION SHIELD
CABLE EXIT
Yellow or Black White
Green
Yellow-Green
Flange for applying suspended loads FLA 703 Ball joint SND022
APPLICATION NOTES
Mounting with double joint and flange for suspended loads
Wall mounting with ball joint.
0 - 500 K5C 0 - 1000 K1M
4x0.25 Screened cable
Shield
White
Green
Joint
Red
Yellow
Red Yellow or Black
White Green
Yellow-Green
Red Yellow or Black
White Green
Yellow-Green
Yellow-Green
Red Yellow or Black
White Green
SHUNT BOX