TR5N
Resistance Thermometers for the Measure of Temperature on Extruders
Main features
• Temperature limits: - 40 ... + 250° C
(see table for the type of used thermocouple cable)
• Tolerance: Norme UNI 7937, IEC 751:
± 0.15° C to 0° C for class A (1/2 DIN)
± 0.30° C to 0° C for class B (1 DIN)
• Stainless steel AISI 303 sheath
• Adjustment spring thread connection: 8mm diameter,
300mm length
MODELS
with bayonet fitting
F
Li
Lc
ORDER CODE
N X
5
R
T
CODE
Element + Nr. of Wires
Single 2 wires
Single 3 wires
Double 2 wires 3
Precision Class
PT100 classe A (1/2 DIN)
PT100 classe B (1 DIN)
Cable (DIN standards)
PVC 1
GSC
Screened GSC
TTS
TES
(*) Not available with dual element 2/3 wire (3)
Not available with single-element 4-wire (5)
Sheath Material
AISI 303
Sheath Diameter (mm)
5
6
8
(*) Standard sheath length 15mm
(**) Standard sheath length 15 - 25 - 35mm
(***) Standard sheath length 10mm
Connection Thread
1/4” GAS “A”= 12mm
M12 x 1
M12 x 1.5
M12 x 1.75
Connection Material
Nickel plated brass
1
2
A
B
2
3 (*)
5
6
Q
H *
I **
J ***
B
O
P
Q
1
0
0 0 0
X
Certificates
Conformity ReportA
LENGTHS AND
ACCESSORIES
Li = Immersion Length (mm) *
10 - 15 - 25 - 35mm
(*) Non-standard lengths can be supplied
for 6mm and 8mm diameters only
Connectors
A
B
C
Lc = Cable length (dm)
Standard length from 10 to
100dm with 5dm step
Standard male
Standard male + female
Standard male + panel
GEFRAN spa reserves the right to make any kind of design or functional modification at any moment without prior notice
DTS_TR5N_12-2015_ENG