Gefran TC6 Data Sheet

TC6
Thermocouples for use in a wide range of industrial applications
Main features
• Temperature limits:
- 40 ... + 350° C for type T
- 40 ... + 750° C for type J
- 40 ... + 900° C for type E
- 40 ... + 1000° C for type K (see table for sheath diameters)
• Tolerance (IEC standard 584.2/Class 2): for type T: ± 1° C (- 40 ... + 133° C) ± 0.0075 [t] (t > + 133° C) for type J, E, K: ± 2.5° C (- 40 ... + 333° C) ± 0.0075 [t] (t > + 333° C)
• Ceramic insulation of the thermocouple element
• Application versatility
MODELS
without fitting
TC6 A
TC6 B
with adjustable
compression fitting
B
A
F
Li
Li
TC6 C
with welded fitting
Le
A
F
Li
TC6 D
with welded fitting
under the head
A
F
Li
TC6 E
with female fitting and
welded ring
Le
F
Li
Ø
Ø
Ø
Ø
Ø
ORDER CODE
CODE
Model
Without fitting With adjustable compression fitting With welded fitting
With welded fitting under the head
With female fitting and welded ring
(*) Available just with: 1/2” GAS thread
Element + Hot Junction
Single Insulated Single Grounded Double Insulated Double Grounded
Thermocouple Type
Fe - Cu/Ni Ni/Cr - Ni/Al Cu - Cu/Ni T Ni/Cr - Cu/Ni E
Connection Head
Mignon
DIN J DIN B DIN BUS EEX d IIC 2GD CEAA
(*) For single element only
T C 6 0
A
B
C D
E*
1 2 3 4
J K
A*
B C E F H
0 0 0
A
XX
(*) Available for TC6C and TC6E models only
X
Certificates
LENGTHS AND ACCESSORIES
Li = Immers. Length (mm)
Standard Length from 50 to
1000mm with 50mm step
Le = Extens. Length (mm) *
Standard Length from 35 to
200mm with 10mm step
B
Conformity ReportA
Sheath Material
AISI 304 AISI 310
AISI 316 INCONEL 600
Sheath Diameter (mm)
5
6
8 10 12
Connection Thread *
1/8” GAS “A”= 10mm 1/4” GAS “A”= 12mm 3/8” GAS “A”= 15mm 1/2” GAS “A”= 15mm
1/8” NPT 1/4” NPT 3/8” NPT 1/2” NPT
(*) To be shown for B, C, D, E models only
Connection Material *
Nickel-Plated Brass
300 Series Stainless Steel
A B C F
H
I J K L
A B C D G H
I J
1**
(*) To be shown for B, C, D, E models only
2
(**) Available for TC6B model only
Mod. B Mod. C e D
MOUNT (F) A (mm) B (mm) A (mm)
G 1/8 10 35 10 G 1/4 12 35 12 G 3/8 15 40 15 G 1/2 15 40 15
1/8 NPT 11 35 11 1/4 NPT 16 40 16 3/8 NPT 16 40 16 1/2 NPT 20 45 20
C
E
F
H
Availability of Mounts /Sheathing Diameter
Mount (F) ø5 ø6 ø8 ø10 ø12 G 1/8 x x - - ­G 1/4 x x x - ­G 3/8 x x x x ­G 1/2 x x x x x 1/8 NPT x x - - ­1/4 NPT x x x - ­3/8 NPT x x x x ­1/2 NPT x x x x x
GEFRAN spa reserves the right to make any kind of design or functional modification at any moment without prior notice
DTS_TC6_12-2015_ENG