Gefran TC5N Data Sheet

TC5N
Ø
Thermocouple for use in the plastics industry
Main characteristics
• Max. temperature limit: - 40 ... + 250° C (see table for thermocouple cable used)
• Reference tolerances: Standards IEC 584.2 class 2: for type J, K: ± 2.5° C (- 40 ... + 333° C)
• Mount threading adjustment spring: ø 8mm, length 300mm.
• Cable to DIN standard
MODELLO
TC5 N: with bayonet mount
F
Li
Lc
ORDER CODE
A
B
C
D
E
C 5 N
T
CODE
Element + heat junction
Isolated single
Grounded single Isolated double Grounded double
Element type
Fe - Cu/Ni Ni/Cr - Ni/Al
Cable (to DIN standard)
GSC Shielded GSC TTS TES
1
2 3 4
J K
2
3 (*)
5 6
(*) Not available with dual element
Tip material
AISI 303
Tip diameter (mm)
5 6 8
(*) Standard sheathing length 15mm (**) Standard sheathing length: 15 - 25 - 35mm (***) Standard sheathing length 10mm
Mount threading (F)
G1/4 M12 x 1
M12 x 1,5 M12 x 1,75
Mount material
Nickel-plated brass
Q
H * I ** J ***
B O
P Q
1
0 0 0 X X
(*) Lengths differ from standard only for sheathing diameters 6 and 8 mm
CONNECTOR TYPE
A
LENGTHS AND ACCESSORIES
Li = Immersion length (mm) *
10 - 15 - 25 - 35mm
A B C D E
Connector type
Lc = Cable length (dm)
Standard length from 5 to 100dm
Certificates
Certificate of conformity
Standard male
Standard male + female
Standard male + panel
Mignon male
Mignon male + female
with 5dm pitch
GEFRAN spa reserves the right to make aesthetic or functional changes at any time and without notice
DTS_TC5N_12-2015_ENG