Gefran TC1 Data Sheet

TC1
Ø
Thermocouple for use in the plastics industry
Main characteristics
• Max. temperature limit: - 40 ... + 250° C (see table for thermocouple cable used)
• Reference tolerances: Standards IEC 584.2 class 2: for type J, K: ± 2.5° C (- 40 ... + 333° C)
• Cable to DIN standard
• Low cost
MODELS
TC1 A: without mount
Ø
TC1 B: with sliding mount
Ø
Li
Li
A
F
B
Lc
Lc
TC1 C: with welded mount
A
F
Li
B
Lc
ORDER CODE
E
D
A
B
C
T C 1
CODE
Without mount
With sliding compression mount
With welded mount
Isolated single Grounded single Isolated double Grounded double
Fe - Cu/Ni Ni/Cr - Ni/Al
GSC
Shielded GSC
TTS TES
(*) Not available with 3mm sheathing (**) Not available with 3, 4, 5mm sheathing / Not available with dual element
Stainless steel
Sheathing diameter (mm)
3 4 5 6 8
(*)Not available with double element
G 1/8 G 1/4 G 3/8 G 1/2 1/8 NPT 1/4 NPT 3/8 NPT 1/2 NPT
To be specified only for models B and C
Nickel-plated brass
AISI 303
To be specified for model B Always specify for model C (2)
Model
A
B
C
Element + heat junction
1 2 3 4
Element type
J K
Cable (to DIN standard)
2*
3**
5 6
Sheathing material
A
E*
F*
H
I
J
Mount threading (F)
A B C D
G
H
I
J
Mount material
1 2
0 0 0 X
CONNECTOR TYPE
Certificates
A
Li = Immersion length (mm)
Standard length from 50 to 1000mm
G*
* Not available with shielded GSC cable
Not available with Mignon connector cable
A B C D E
Certificate of conformity
LENGTHS AND ACCESSORIES
with 50mm pitch
Armature
Stainless steel sheathing
Connector type
Lc = Cable length (dm)
Standard length from 5 to 100dm
with 5dm pitch
Standard male
Standard male + female
Standard male + panel
Mignon male
Mignon male + female
TC1B TC1C
MOUNT (F) A (mm) B (mm) A (mm) B (mm) G 1/8 10 35 10 20 G 1/4 12 35 12 25 G 3/8 15 40 15 30 G 1/2 15 40 15 30 1/8 NPT 11 35 11 25 1/4 NPT 16 40 16 30 3/8 NPT 16 40 16 30 1/2 NPT 20 45 20 35
Availability of Mount/Sheathing diameter
ø3 ø4 ø5 ø6 ø8 G 1/8 x x x x ­G 1/4 x x x x x G 3/8 x x x x x G 1/2 - - x x x 1/8 NPT x x x x ­1/4 NPT x x x x x 3/8 NPT x x x x x 1/2 NPT - - x x x
GEFRAN spa reserves the right to make aesthetic or functional changes at any time and without notice.
DTS_TC1_12-2015_ENG