Gefran PA1 Data Sheet

PA1
RECTILINEAR DISPLACEMENT TRANSDUCER
Principal characteristics
• The transducer’s compactness makes it suitable for installation in small spaces and for detecting small shifts.
• The joint with up-take of slack and M4 threading provides greater tolerances in movement.
• Installation is simplified by the lack of electrical signal variation at output outside theoretical electrical stroke.
• Ideal for small mechanical devices, valves, and test tools and benches.
TECHNICAL DATA MECHANICAL DIMENSIONS
Useful electrical stroke (C.E.U.)
Resolution Infinite
Independent linearity (within C.E.U.)
Displacement speed ≤ 5 m/s
Life
Vibrations
Shock 50 g, 11ms.
Tolerance on resistance ± 20%
Recommended cursor current
Maximum cursor current 10mA
Maximum applicable voltage
Electrical isolation >100MΩ a 500V=, 1bar, 2s
Dielectric strength < 100 mA a 500V~, 50Hz, 2s, 1bar
Dissipation at 40°C (0W at 120°C)
Actual Temperature Coefficient of the output voltage
Working temperature -30...+100°C
Storage temperature -50...+120°C
Case material Anodised aluminium Nylon 66 G 25
Control rod material Stainless steel AISI 303
Fixing
Important: all the data reported in the catalogue linearity, lifetime, temperature coefficient are valid for a sensor utilization as a ratiometric device with a max current across the cursor Ic ≤ 0.1 mA.
25/50/75/100/125/150
see table
>25x106m strokes,or 100x106 operations, whichever is less (within C.E.U.)
5...2000Hz, Amax =0,75 mm amax. = 20 g
< 0,1 mA
see table
3 pole cabel
see table
< 1,5ppm/°C
Brackets with variable longitudinal axise
MECHANICAL / ELECTRICAL DATA
Model 25 50 75 100 125 150
Useful electrical stroke (C.E.U.) + 1 / -0 mm 25 50 75 100 125 150
Theoretical electrical stroke (C.E.T.) ± 1 mm C.E.U. +1
Resistance (on C.E.T.) 1 5 5 5 5 5
Independent linearity (within C.E.U.) ± % 0.2 0.1 0.1 0.1 0.05 0.05
Dissipation at 40°C (0W at 120°C) W 0.6 1.2 1.8 2.5 3 3.6
Maximum applicable voltage V 25 60
Mechanical stroke (C.M.) mm C.E.U. +5
Case length (A) mm C.E.U. +49.5
Total length (B) mm 113.2 163.2 213.2 263.2 313.2 363.2
ELECTRICAL CONNECTIONS
COUPLING JOINT
Connector
output
Connection
Side
Cable
output
Blue
Yellow
Brown
INSTALLATION INSTRUCTIONS
• Respect the indicated electrical connections (DO NOT
use the transducer as a variable resistance)
• When calibrating the transducer, be careful to set the stroke so that the output does not drop below 1% or rise beyond 99% of the supply voltage.
OPTIONAL FIXING KIT PKIT006
ANGULAR FREEDOM ± 10°
AXIAL FREEDOM ± 0,5mm
ORDER CODE
S
Displacement transducer PA1
3 pole PVC cable output 3x0.25 1m.
5 pole connector
output DIN 43322
Model
F
C
Ex.:PA1 - C - 100 Displacement transducer model PA1, 5 pole connector output, useful electrical stroke (C.E.U.) 100mm
M
Cable length
(in meters)
This part of the code only applies to the model with cable output
No certicate
attached
Linearity curve to be attached
Standard mounting brackets (PKIT005)
Optional mounting brackets (PKIT006)
Color of plastic heads (green)
0
L
X
S
0
0 0 0 X 0 0 0
0
0