MELT PRESSURE TRANSMITTERS FOR APPLICATIONS IN
POTENTIALLY EXPLOSIVE ATMOSPHERES
MX SERIES 4-20mA Output
The MX series of Gefran, are pressure transmitters for
using in High temperature environment.
The main characteristic of this series is the capability to
read temperature of the media up to 400°C.
The constructive principle is based on the hydraulic trasmission of the pressure.
The fluid-filled system assures the temperature stability.
ATEX
The phisical measure is transformed in a electrical measure by means the strain-gauge technology.
MAIN FEATURES
• Pressure ranges: 0-35 to 0-2000bar / 0-500 to
0-30000psi
• Extensimetric measurement principle with Wheatstone
bridge
• Precision: <±0.25% FSO (H); <±0.5% FSO (M)
• Calibration signal 80% FSO internally generated
• Completely interchangeable with all existing products
• Protection level: IP65 (6-pin connector)
• Standard threading 1/2-20UNF, M18x1.5, other versions on
request
• Stainless steel diaphragm 15-5 PH with GTP+ coating
• For ranges below 100 bar-1500 psi: 17-7 PH corrugated
stainless steel diaphragm with GTP+ coating
• Other diaphragm types available on request
MX0 The rigid rod configuration provides fast and easy
installation.
MX1 The flexible rod configuration is suitable for
applications demanding greater thermal isolation
and where installation would otherwise be difficult.
MX2 This configuration lets you measure process
pressure and temperature at the same point with a
single installation.
MX3 The configuration with exposed tip is ideal for
applications in limited space.
Main intrinsic safety characteristics
Transmitter designed and produced in compliance with Directive
ATEX 2014/34/EU and according to European standards:
for the second group (II-surfaces), category1,explosive atmosphere
with presence of gases, fumes or mists (G) protection mode Ex ia IIC
T5, T4 room temperature -20°C/+55°C/+60°C/+70°C
Maximum voltage 30 V
Maximum current 100 mA
Maximum power 0,75 W
Equivalent inductance (*) 0,23 mH
Equivalent capacity (*) 26 nF
(*) includes inductance levels and capacity of a cable:
(typical L 1microH/m and typical C 100pF/m)
with maximum length 15m.
TECHNICAL SPECIFICATIONS
Rated precision, including effects
of Linearity, Repeatability and
Hysteresis
Resolution
Pressure ranges
Maximum applicable pressure
Principle of measurement
Power supply
Maximum input
Isolation resistance (at 50 Vdc)
Signal at rated pressure (FSO)
Zero balancing
Calibration: Rated pressure
Room pressure
Maximum load
Response time (10 at 90% FSO)
Output noise (RMS 10-400Hz)
Calibration signal
Protection against overvoltages and
power supply polarity reverse
Temperature range of Strain Gauge
Housing
Thermal drift in compensated range:
Zero/Calibrat/Sensitivity
Maximum temperature of diaphragm
Influence due to fluid temperature
change (zero)
Standard material in contact
with process medium
Thermocouple (model MX2)
Protection level (with 6-pin female
connector installed)
Electrical connections
FSO = Full Scale Output (Signal at rated pressure)
Power at zener barrier or active barrier. For version MX2, the thermocouple must be connected to EX-i circuits with devices assigned to galvanic
separation and with protection mode [EX ia] IIC.
EC-Type Examination Certificate number:
CESI 02 ATEX 107
H <±0.25%FSO (100...2000 bar)
M <±0.5%FSO (35...2000 bar)
Infinite
0..35 to 0..2000bar
0..500 to 0..30000psi
2 x FS
1,5 x FS beyond 1000bar/15000psi
Strain gauge
12...30Vdc
30mA
>1000 MOhm
20mA
4mA
5% FSO
min. 10bar (150psi)
see diagram (page 3)
~ 4ms
< 0.05% FSO
80% FSO
YES
-20...+70°C
-4...+158°F
< 0.02% FSO/°C
< 0.01% FSO/°F
400°C / 750°F
0.02 bar/°C
15 psi/100°F
Diaphragm:
• 15-5 PH with GTP+ coating
• 17-7 PH corrugated diaphragm
with GTP+ coating for ranges
<100 bar (1500psi)
Stem:
• 17-4 PH
STD: type “J” (isolated junction)
IP65
6-pin conn. VPT07RA10-6PT
(PT02A-10-6P)
8-pin conn. PC02E-12-8P

MECHANICAL DIMENSIONS
MX0 MX2
D1
1/2 - 20UNF
ø7.8 -0.05
D2
[ ø0.31” -0.002 ]
ø10.5 -0.025
D3
[ ø0.41” -0.001 ]
D4
D5
A
B
C
Ch
[Hex]
MX1 MX3
D1
D2
D3
D4
D5
ø10.67
[ ø0.42” ]
ø12.7
[ ø0.5” ]
5.56 -0.26
[ 0.22” -0.01 ]
11.2
[ 0.44” ]
15.74
[ 0.62” ]
16
[ 5/8” ]
M18x1.5
ø10 -0.05
[ ø0.394” -0.002 ]
ø16 -0.08
[ ø0.63” -0.003 ]
ø16 -0.4
[ ø0.63” -0.016 ]
ø18
[ ø0.71” ]
A
B
C
Ch
[Hex]
6 -0.26
[ 0.24” -0.01 ]
14.8 -0.4
[ 0.58” -0.016 ]
19
[ 0.75” ]
19
[ 3/4” ]
NOTE : dimensions refer to rigid stem length option “4” (153 mm – 6”)
WARNING : For installation use a maximum tightening torque of 56 Nm(500 in-lb)

ELECTRICAL CHARACTERISTICS AND TEMPERATURE CLASSES
MODEL (*) LEVEL (*) LEVEL TEMPERATURE ROOM
L2 L1 CLASSES TEMPERATURE
MX0 > 165mm > 125mm T4 -20...+60°C
MX1 > 665mm > 625mm T5 -20...+55°C
T4 -20...+70°C
MX2 > 665mm > 625mm T5 -20...+55°C
T4 -20...+70°C
MX3 > 665mm > 625mm T5 -20...+55°C
T4 -20...+70°C
(*) with the level (L) in fig. 1, the table sets the
minimum distance that the electrical circuit has
to maintain from the block at high temperature.
thermal isolating material with adequate
thickness for the process temperature
pressure transmitter housing block
fluid at temperature (400°C)
ELECTRICAL CONNECTIONS Output in current (4...20mA 2 wires)
6-pin 8-pin
L1
L2
Power supply
(12...30Vdc)
Signal
(4...20mA)
Calibrtation shunt
+
n.c.
n.c.
A
C
-
B
D
E - F
n.c.
The cable sheathing is con-
nected to the transducer body
B
A
D
C
E - F
G - H
6 pin connector
VPT07RA10-6PT2
(PT02A-10-6P)
LOAD DIAGRAM (current output) SETTINGS
AREA OF
POSSIBLE
USE
8 pin connector
PC02E-12-8P Bendix
LOAD RESISTANCE RL
The diagram shows the best ratio of load to power supply for
transmitters with 4…20mA output. For correct function, use a
combination of load resistance and voltage that stays in the
shaded zone.
Accessories
Fastening bracket SF18
Protection plug for 1/2-20 UNF SC12
Protection plug for M18x1.5 SC18
Drill kit for 1/2 -20 UNF KF12
VOLTAGE
The signal setting to room pressure (ZERO) and the setting to
rated pressure (SPAN) can be made with the appropriate
trimmers, accessed inside the transmitter after removing the
two fastening screws.
The SPAN setting is made during production and must not
be changed.
Extension cables
6-pin connector with 3mt Atex cable PCAV221
6-pin connector with 4mt Atex cable PCAV104
6-pin connector with 5mt Atex cable PCAV105
6-pin connector with 10mt Atex cable PCAV106
Drill kit for M18 x 1.5 KF18
Cleaning kit for 1/2-20 UNF CT12
Cleaning kit for M18x1.5 CT18
Thermocouples for model MX2
Type “J” (for rigid rod 153mm - 6”) TTER 718

ORDER CODE
M
OUTPUT SIGNAL
4...20mA
CONFIGURATION
Rigid rod
Rigid rod + flexible
With thermocouple
Exposed tip
CONNECTOR
Standard
6 pin 6
8 pin 8
PRECISION CLASS
(ranges ≥100 bar/1500 psi)
MEASUREMENT RANGE
bar
3550B35U
70 B07D
100 B01C
200
350 B35D
500 B05C
700
1000 B01M
1400 B14C
2000 B02M
0.25% FSO
0.5% FSO M
500
B05D
B02C
B07C
750
1000 P01M
1500 P15C
3000 P03M
5000 P05M
7500 P75C
10000 P10M
15000 P15M
20000 P20M
30000 P30M
psi
Notes:
the models MX0/MX1/MX3 are available in a special version
XM3GD realized to work in the presence of gases (zone 2)
and powders (zone 22).
Marking:
Examples:
MX1-6-M-B05C-1-4-D-5-(XM3GD)
Example
MX1-6-M-B07C-1-4-D-4-000
Melt pressure transducer with flexible rod, 4…20mA output, 6-pin connector, fi-20 UNF
threading, pressure range 700 bar, precision class 0.5%, 153 mm (6”) rigid rod, 457 mm
(18”) flexible rod, temperature class T4
Sensors are manufactured in compliance with:
X
0
1
2
3
H
P05C
P75D
II 3G Ex nA IIC T4,T5,Gc
II 3D Ex tc IIIC T135°C,T100°C Dc,IP65
000
000= Special executions of the
standard version or of custom
versions may be requested.
4
T4
T55
NOTES: Series MX0 available
only in T4 class
FLEXIBLE ROD LENGTH
(mm / inches)
Standard (MX0)
0
none
Standard (MX1, MX2)
D
457mm
610mmE
760mmF
Standard (MX3)
L
711mm
Available on request
A
76mm
B
152mm
C
300mm
G
914mm
H
1067mm
I
1220mm
J
1372mm
K
1520mm
RIGID ROD LENGTH
(mm / inches)
Standard (MX0, MX1, MX2)
4
153mm
318mm5
Standard (MX3)
none
0
Available on request
1
38mm
2
50mm
3
76mm
6
350mm
400mm
7
8
456mm
1) use rod MX1 and MX2 in combination
with sheathings or rigid rods so that
total length L is ≥ 630mm
THREADING
Standard
1
1/2 - 20 UNF
M18 x 1.54
Available on request
M10 x 1
2
(ranges ≥200bar / 3000psi)
3
M14 x 1.5
18”
24”
30”
28”
3” 1)
6” 1)
12” 1)
36”
42”
48”
54”
60”
6”
12.5”
1.5” 1)
2” 1)
3” 1)
14”
16”
18”
- EMC compatibility directive
- ATEX
Product designed and available in compliance with Directive 2011/65/EU (RoHS II) only for large-scale stationary installation or industrial tools, or for B-to-B laboratory equipments for R&D purposes.
Electrical installation requirements and Conformity certificate are available on our web site: www.gefran.com
GEFRAN spa reserves the right to make aesthetic or functional changes at any time and without notice.
DTS_MX_07-2017_ENG