Gefran ME SERIES Data Sheet

MELT PRESSURE TRANSMITTERS
ME SERIES PERFORMANCE LEVEL ‘c’
Output 4...20mA
The ME Performance Level ‘c’ series of Gefran are pressure transmitters for using in high temperature envi­ronment. The main characteristic of this series is the capability to read temperature of the media up to 400°C. The constructive principle is based on the hydraulic tra­smission of the pressure. The fluid-filled system assures the temperature stability. The phisical measure is transformed in a electrical mea­sure by means of the strain-gauge technology.
MAIN FEATURES
• Pressure ranges from: 0-17 to 0-2000 bar / 0-250 to 0-30000 psi
• Accuracy: < ±0.25% FSO (H); < ±0.5% FSO (M)
Fluid-filled system for temperature stability
Mercury filling volume: ME0 (30mm3); ME1, ME2, ME3 (40mm3)
1/2-20UNF, M18x1.5 standard threads; other types avai- lable on request
• Autozero function on board / external option
• Standard diaphragm is 15-5 PH stainless steel with GTP+ coating
• 17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100 bar-1500 psi
GTP+ (advanced protection) Coating with high resistance against corrosion, abrasion and high temperature
AUTOZERO FUNCTION
All signal variations in the absence of pressure can be eli­minated by using the Autozero function. This function is activated by closing a magnetic contact located on the transmitter housing. The procedure is permitted only with pressure at zero.
TECHNICAL SPECIFICATIONS
Accuracy (1)
Resolution 16 bit
Measurement range
Maximum overpressure (without degrading performances)
Measurement principle Extensimetric
Power supply 13...30Vdc
Maximum current absorption
Output signal Full Scale FSO 20mA
Zero balance (tollerance ± 0.25% FSO)
Response time (10...90% FSO) 8ms
Output noise (RMS 10-400Hz) < 0.025% FSO
Calibration signal 80% FSO
Power supply polarity reverse protection
Compensed temperature range housing
Operating temperature range hou­sing
Storage temperature range housing -40...+125°C
Thermal drift in compesated range: Zero / Calibration / Sensibility
Diaphragm maximum temperature 400°C / 750°F
Zero drift due to change in process temperature (zero)
Standard material in contact with process medium
Thermocouple (model ME2) STD : type “J” (isolated junction)
Protection degree (with 6-pole female connector)
FSO = Full scale output : (1) BFSL method (Best Fit Straight Line): includes combined effects of Non-Linearity, Hysteresis and Repeatability.
H <±0.25%FSO (100...2000 bar) M <±0.5%FSO (35...2000 bar)
0..17 to 0..2000bar
0..250 to 0..30000psi
2 x FS
1.5 x FS above 1000bar/15000psi
23mA
(40mA with relay optional)
4mA
YES
0...+85°C
-30...+85°C
< 0.02% FSO/°C
< 0.02 bar/°C
Diaphragm:
• 15-5PH with GTP+ coating
• 17-7 PH corrugated diaphragm with GTP+ coating for ranges <100bar (1500psi) Stem: • 17-4 PH
IP65
MECHANICAL DIMENSIONS
ME0
D1
D2
D3
D4
D5
A
B
C
Ch
[Hex]
D1
D2
ME2
1/2 - 20UNF
ø7.8 -0.05
[ ø0.31” -0.002 ]
ø10.5 -0.025
[ ø0.41” -0.001 ]
ø10.67
[ ø0.42” ]
ø12.7
[ ø0.5” ]
5.56 -0.26
[ 0.22” -0.01 ]
11.2
[ 0.44” ]
15.74
[ 0.62” ]
16
[ 5/8” ]
M18x1.5
ø10 -0.05
[ ø0.394” -0.002 ]
ME1
D3
D4
D5
A
B
C
Ch
[Hex]
ø16 -0.08
[ ø0.63” -0.003 ]
ø16 -0.4
[ ø0.63” -0.016 ]
ø18
[ ø0.71” ]
6 -0.26
[ 0.24” -0.01 ]
14.8 -0.4
[ 0.58” -0.016 ]
19
[ 0.75” ]
19
[ 3/4” ]
ME3
NOTE : dimensions refer to rigid stem length option “4” (153 mm – 6”)
WARNING : For installation use a maximum tightening torque of 56 Nm (500 in-lb)
SELF DIAGNOSTICS
0
100
200
300
400
500
600
700
800
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
Vcc (Volt)
R (ohm)
Below the conditions detected by the sensor self-diagnostics:
· Cut cable / device non connected / broken power supply, output <3.6mA
· Pin detachment, output >21mA
· Pressure above 200% of the span, output >21mA
· Voltage monitor in case of overvoltage/undervoltage/voltage variation in the electronics, output <3.6mA
· Program sequence error, output <3.6mA
· Overtemperature on the electronics, output <3.6mA
· Error on the primary element output or on the first amplification stage, output <3.6mA
OPTIONAL RELAY OUTPUT FOR EXCESS PRESSURE PROTECTION
Safety relay characteristics:
· Activation threshold to be defined in the order code
· Rated carry current: 1A
· Rated voltage: 24Vdc ± 20%
· Switch accuracy: 2 x sensor accuracy
· Hysteresis: 2% FSO
SUPPLY OUTPUT RELAY STATUS
OFF - OPEN
ON < X%fs CLOSED
ON > X%fs OPEN
ON output < 3,6mA OPEN
ON output > 21mA OPEN
NAMUR COMPLIANCE
The sensors are tested according to Namur NE21 recommendations. The same compatibility is valid for the NE43 Namur recommendation with the following sensor behaviour in case of breakdown:
· Cut cable: breakdown information as the signal is <3,6mA
· Device not connected: breakdown information as the signal is <3,6mA
· Broken power-supply: breakdown information as the signal is <3,6mA
or in case of performance problems:
· most common failures on primary sensors: the signal goes to>21mA
Note: in all the remaining situations, the output signal is always inclu­ded between 3,6 and 21mA.
Recommendation: the error level set by the customer (e.g. maximum pressure value) has to be inside the nominal range.
AUTOZERO FUNCTION
LOAD DIAGRAM
The diagram shows the optimum ratio between load and power supply for transmitters with 4…20mA output. For correct function, use a combination of load resistance and voltage that falls within the two lines in the graph above.
The Autozero function is activated through a magnetic contact (external magnet supplied with the sensor). See the manual for a complete Autozero fun­ction explanation.
ELECTRICAL CONNECTIONS
EXTERNAL AUTOZERO
EXTERNAL AUTOZERO
CURRENT OUTPUT
CONTROLLER
POWER SUPPLY
7-pin
F
The cable shield is tied to connector via cable clamp
RELAY OUTPUT
OUTPUT
POWER SUPPLY
AUTOZERO
C
B
D-G
A-E
The cable shield is tied to connector via cable clamp
CONTROLLER
POWER SUPPLY
OUTPUT
POWER SUPPLY
RELAY CONTACT
AUTOZERO
7-pin
F
C
B
D-G
A-E
ELECTRICAL CONNECTIONS
6 pin connector VPT07RA10-6PT2
(PT02A-10-6P)
7 pin connector (AMPHENOL) 62IN-5016-10-7P-4-M
8 pin connector (Binder)
M16 DIN/EN45326 (09-0173-00-08)
ACCESSORIES
Connectors
6-pin female connector (IP65 protection degree) CON300 7-pin female connector (IP65 protection degree) CON345 8-pin female connector (IP65 protection degree) CON027
Extension cables
6-pin connector with 8m (25ft) cable C08WLS 6-pin connector with 15m (50ft) cable C15WLS 6-pin connector with 25m (75ft) cable C25WLS 6-pin connector with 30m (100ft) cable C30WLS
8-pin connector with 8m (25ft) cable C08WLS8 8-pin connector with 15m (50ft) cable C15WLS8 8-pin connector with 25m (75ft) cable C25WLS8 8-pin connector with 30m (100ft) cable C30WLS8
Accessories
Mounting bracket SF18 Dummy plug for 1/2-20UNF SC12 Dummy plug for M18x1.5 SC18 Drill kit for 1/2-20UNF KF12 Drill kit for M18x1.5 KF18 Cleaning kit for 1/2-20UNF CT12 Cleaning kit for M18x1.5 CT18 Fixing pen clip PKIT 379 Autozero pen PKIT 378
Thermocouple for ME2 model
Type “J” (153mm - 6” rigid rod) TTER 601
Cable color
code
Conn. Wire
A-2 Red
B-4 Black
C-1 White
D-6 Green
E-7 Blue
F-3 Orange
5 Grey
8 Pink
ORDER CODE
M
OUTPUT SIGNAL
4...20mA E
VERSION
Rigid rod 0 Rigid + flexible rod 1 With thermocouple 2
Exposed capillary 3
CONNECTOR
6 pin 6 7 pin 7 8 pin 8
ACCURACY CLASS
(ranges ≥ 100 bar/1500 psi)
0.25% FSO
0.5% FSO M
MEASUREMENT RANGE
bar psi
17 B17U 250 P25D 35 B35U 500 P05C 50 B05D 750 P75D
70 B07D 1000 P01M 100 B01C 1500 P15C 200 B02C 3000 P03M 350 B35D 5000 P05M 500 B05C 7500 P75C 700 B07C 10000 P10M
1000 B01M 15000 P15M 1400 B14C 20000 P20M 2000 B02M 30000 P30M
THREADING
1/2 - 20 UNF 1
M18 x 1.5 4
Example
ME1-6-M-B07C-1-4-D-P
Melt pressure transducer, 4...20mA output, 6-pin connector, 1/2-20 UNF threading, 700 bar
pressure range, 0.5% accuracy, 153 mm (6”) rigid rod, 457 mm (18”) flexible rod; Performance
Level=’c’.
Sensors are manufactured in compliance with:
H
Standard
0000
X 000 X 00
Output Relay Version (activation threshold): X=no relay B=80%fs A=70%fs C=90%fs
000= Special executions
E External Autozero (*)
- Magnetic Autozero
(*) as an alternative to the CAL function
P Performance Level=’c’
FLEXIBLE ROD LENGTH
(mm/inches)
Standard (ME0)
0 none
Standard (ME1,ME2)
457mm 18”
D E 610mm 24” F 760mm 30”
Standard (ME3)
711mm 28”
L
Available on request
76mm 3”
A B 152mm 6” C 300mm 12” G 914mm 36” H 1067mm 42”
I 1220mm 48” J 1372mm 54” K 1520mm 60”
RIGID ROD LENGTH
(mm/inches)
Standard (ME0, ME1, ME2)
153mm 6”
4
5 318mm 12.5”
Standard (ME3)
0 none
Available on request
38mm 1.5”
1
2 50mm 2”
3 76mm 3”
6 350mm 14”
7 400mm 16”
8 456mm 18”
- EMC directive
- machinery directive
Product designed and available in compliance with Directive 2011/65/EU (RoHS II) only for large-scale stationary installation or industrial tools, or for B-to-B laboratory equipments for R&D purposes
Electrical installation requirements and Conformity certificate are available on our web site: www.gefran.com
GEFRAN reserves the right to make any kind of design or functional modification at any moment without prior notice
DTS_ME-PLc_07-2017_ENG