Gefran MD SERIES Specification Sheet

MELT PRESSURE TRANSMITTERS
MD SERIES DP404 CAN OPEN digital output
The MD series of Gefran, are pressure transmitters for using in High temperature environment. The main characteristic of this series is the capability to read temperature of the media up to 400°C. The constructive principle is based on the hydraulic tra­smission of the pressure. The fluid-filled system assures the temperature stability. The phisical measure is transformed in a electrical mea­sure by means the strain-gauge technology.
MAIN FEATURES
Electrical
• Digital output signal with DP404 CAN OPEN communica­tion protocol
• Transmission frequency (Baud rate): 10 Kbaud to 1 Mbaud (default 500 Kbaud)
• Software selection of Baud rate and ID nodes
• Operation with 1 or 2 settable alarm limits
• “Autozero” for temperature compensation
• Zero and span drift compensation
• 80% FSO calibration signal
Mechanical
• Pressure ranges:
0-35 to 0-2000 bar / 0-500 to 0-30000 psi
• Accuracy: < ± 0.25% FSO (H); < ±0.5% FSO (M)
• Hydraulic transmission system to guarantee temperature stability.(Hg)
• Quantity of Hg contained for model:
series MDE0 (30mm3); series MD1, MD2, MD3 (40mm3)
• Standard threading: 1/2-20 UNF, M18x1.5; other versions on request
• Autozero function by software
• Stainless steel 15-5 PH diaphragm with GTP+ coating
• For ranges below 100 bar – 1500 psi: stainless steel
17-7PH corrugated diaphragm with GTP+ coating
GTP+ (advanced protection) Coating with high resistance
against corrosion, abrasion and high temperature
TECHNICAL SPECIFICATIONS
Rated precision, including effects of line-
arity, repeatability and hysteresis
Sampling
Pressure ranges
Maximum applicable pressure
Measurement principle
Power supply
Typical input
Insulation resistance (at 50Vdc)
Signal at rated pressure (FSO)
Signal at ambient pressure
Calibration of ambient pressure
Signal protocol
Response time (10 at 90% FSO)
Electronic response time
(10 at 90% FSO)
Calibration signal
Protection against overvoltage and reverse
polarity of power supply
Compensated temperature range of
strain gauge housing
Maximum temperature range of strain
Gauge Housing
Thermal drift in Zero
compensated range; Calibration
Sensitivity
Max. diaphragm temperature
Influence due to variation of fluid tempe-
rature (zero)
Standard material in contact
with process medium
Thermocouple (model MD2)
Protection level
Electrical connections
H < ±0.25%FSO (100…2000 bar)
M < ±0.5%FSO (35…2000 bar)
0-500 to 0-30.000 psi
Insertion of an offset
DP404 CAN OPEN, with baud rate
selectable from 10K to 1M baud
Diaphragm:
• 15-5 PH with GTP+ coating
• 17-7 PH corrugated diaphragm
with GTP+ coating for ranges
<100 bar (1500psi)
Stem:
• 17-4 PH
STD: Type * J (isolated coupling)
16 bit (1)
0-35 to 0-2000 bari
2 x FSO
Strain gauge
12…40 Vdc
20 mA (2)
>1000 MOhm
Depends on FSO
0
(default 500 Kbaud
20 ms
2 ms
80%FSO
YES
0…+85°C
32…+185°F
-30…+105°C
-22…+221°F
<0.02 %FSO/°C
<0.01 %FSO/°F
<0.01 %FSO/°F
400°C (750°F)
15 Psi/100°F
0.02bar/°C
IP65
M12 DIN EN 50044
5-pin connector
(1) resolution: 0.01bar from 35…500bar; 0.1bar from 700…2000bar;
0.1psi from 5000 …350psi; 1psi from 7500…30000psi (2) Conditions: Power supply 24 Vdc
FSO = Full Scale Output (Signal at rated pressure)
Loading...