Gefran GTZ 25, GTZ 40, GTZ 55 Data Sheet

Main applications
Thermoforming
Plastic extrusion lines
Industrial ovens and
furnaces
Heat treatments
Control applications with
high switching speed
Mold heating/cooling control units
Refrigeration
Air conditioning
GTZ 25 / 40 / 55
THREE-PHASE SOLID STATE RELAYS WITH LOGIC CONTROL Vdc / Vac
Main features
Control input from VDC/VAC logic signal
3-phase alternating current solid state
relay with integrated hestsink
Zero crossing switching
3-phase nominal current
3x25/40/55A
Nominal voltage up to 600VCArms
• Integrated SCR thermal protection with LED signal
• Optional alarm output (for interrupted load diagnostics or for SCR overtem­ perature
Optoinsulation (input/output) 4000Vrms
Integrated overvoltage suppressor
Non-repetitive voltage up to 1200Vp
Component selection to operate at
 max.declaredcurrentwith ≤40°C
temperature
DIN bar mounting with fast clip-on
In Conformity with EN60947-4-3 and
UL508
PROFILE
3-phase “zero crossing” power solid state unit for control of resistive and inductive loads, complete with aluminum heatsink and DIN guide connection. Integrated device designed for industrial applications demanding control of high power levels and frequent switching, with loads up to 3x55A (AC51) at 400/480/600Vac. Control is logic type (VDC or VAC), signa­led by LEDs. Each phase is controlled by means of semiconductors. The constructive elements, special pro­duction process, and new, sturdy case, provide excellent reliability and continuity of service. The device is sized for continuous opera­tion at nominal current at room tempera­ture of 40°C. All versions are protected against overvol­tages and against junction overtempera­ture, with signal LEDs and (optional) solid state alarm output. An optional alarm output is available for interrupted load diagnostics. The device is supplied complete with covers to protect against direct contacts (covers are removable for wiring). Accessories available: fuses, fuse hol-
ders, support for panel mounting, thermo­stats and fans.
TECHNICAL DATA
General features
Category of use: AC51, AC53a
Nominal voltage (Ue): 400Vac (max. range 24...440Vac) (TRIAC) 480Vac (max. range 24..530Vac) (SCR) 600Vac (max. range 24..660Vac) (SCR)
Nominal frequency: 50/60Hz
Peak voltage: <800Vp for models with Ue=400Vac <1200Vp for models with Ue=480Vac, Ue=600Vac
Uninterrupted nominal service.
Critical dV/dt OFF-state: 500V/µs for models with Ue=400Vac 1000V/µs for models with Ue=480Vac, Ue=600Vac
Switching voltage for zero
Activation time: ≤1/2 cycle
Deactivation time: ≤1/2 cycle
Potential drop at rated current: ≤ 1,4Vrms
IP20 protection
Weight: GTZ 25:1100g GTZ 40, 55:1350g
: < 20V
Control inputs
DC INPUT (Type “D”):
Voltage of command circuit (Uc): 5..32Vdc Activation voltage: >4.5Vdc Deactivation voltage: <3Vdc Max. input: 18mA@5Vdc- 22mA@32Vdc Max. reverse voltage: 36Vdc
AC INPUT (Type “A”):
Control voltage: 20...260Vac/Vdc Activation voltage: > 15Vac/Vdc Deactivation voltage: < 6Vac/Vdc Current draw: <= 8 mAac/dc@260Vac/Vdc Additional fuse (3A max) shall be instal­led on the control input circuit.
Outputs
GTZ 25/...
Nominal current (Imax): AC51: 3x25 A AC53a: 3x5 A
GTZ 40/...
Nominal current (Imax): AC51: 3x40 A AC53a: 3x8 A
GTZ 55/...
Nominal current (Imax): AC51: 3x55 A AC53a: 3x15 A
Insulation
Nominal insulation voltage input/output:
2.5KV ac for models with Ue=400Vac
4KV ac for models with Ue=480Vac, Ue=600Vac Nominal impulse withstand voltage (Uimp): 2500Vac
Ambient conditions
• Working temperature: -20°C...80°C
• Max. relative humidity: 50% to 40°C
• Max. installation altitude: 2000 slm
• Pollution level : 2
• Storage temperature: -20...85°C
• Class: A (industrial device)
• Suitable for use in pollution degree 2 environmental
Thermal protection
SCR temperature is constantly monitored inside the device. If the maximum temperature limit is exceeded (T=110°C), current to the load is interrupted and the yellow signal LED lights up.
Options
Option -1 (Thermal protection alarm output).
The alarm output option activates closing of an isolated contact (max 32VAC/VDC, 150mA, conducting resistance <=15 ohm) when it detects the following fault condition: control signal active but SCR/ heatsink is in overtemperature (GTZ ther­mal protection)
Option -2 (Thermal protection alarm output and inter­rupted load). Only for GTZ with Type “A” input.
The alarm output option activates closing of an isolated contact (max 32VAC/VDC, 150mA, conducting resistance <=15 ohm) when it detects the following fault condi­tions:
- Control signal active but no current in at least one three-phase branch (interrupted load)
- Control signal active but no power line voltage (no line)
- Control signal active but SCR / heatsink is in overtemperature (GTZ thermal pro­tection). Maximum delay in tripping of load interrupt alarm < 400ms. Maximum length of wires between GS and load for correct operation of load diagno­stics < 25m
Power supply
Fan supply (only for models GTZ 40/55A): 230Vac 14W (VEN90) 115Vac 14W (VEN91) 24Vdc 4W (VEN92)
Installation notes
Use the high speed fuses specified in the catalog according to the connection exam­ple provided. Applications with solid state power units must also include an automatic safety switch to cut out the load power line.
FACEPLATE DESCRIPTION GTZ with DC control (Models GTZ-xx/xx-D-x)
L1 : Phase 1 input L2 : Phase 2 input L3 : Phase 3 input T1 : Phase 1 output
L1 L2 L3
GTZ 40/600-0-1
VEN-90 fan:230Vac
AC51: 40A 600Vac AC53a: 8A 50/60Hz
T1 T2 T3
L1 L2 L3 A1+
T1T2 T3 A2-
Alarm
On
B1
B2 A1
5..32 Vdc
A2
T2 : Phase 2 output T3 : Phase 3 output A1 : Control signal (+) A2 : Control signal (-) B1 : Alarm output (option) B2: Alarm output (option) Led ON: Red led signal indicator Led Alarm: Yellow led (alarm overtemperature junction)
FACEPLATE DESCRIPTION GTZ with AC control (Models GTZ-xx/xx-A-x)
L1 : Phase 1 input L2 : Phase 2 input L3 : Phase 3 input T1 : Phase 1 output
L2 L3
L1
GTZ 40/600-0-1
fan:230Vac
VEN-90
600Vac
AC51: 40A AC53a: 8A
50/60 Hz
Out-Al
T1 T2 T3
L2L1 L3
T2T1 T3
Alarm
A1+
A2-
B1
B2
A1
20..260 Vac
A2
On
T2 : Phase 2 output T3 : Phase 3 output A1 : Control signal (AC) A2 : Control signal (AC) B1 : Alarm output (option) B2: Alarm output (option) Led ON: Red led signal indicator Led Alarm: Yellow led (alarm overtemperature junction) Led OUT-AL: Red Led interrupted load alarm (with option 2 only)
For maximum reliability, the device MUST
50mm Max
80mm 8
be installed correctly in the panel in order to have adequate heat exchange betwe­en the heatsink and the surrounding air under conditions of natural convection. Mount it vertically (max.10 inclination from the vertical axis)
• Vertical distance between a heatsink and the panel wall >100mm
• Horizontal distance between a heatsink and the panel wall: 20mm at least
• Vertical distance between two heatsink: 300mm at least.
• Horizontal distance between two heat­sink: 20mm. at least Check that cable raceways do not reduce these distances; should it happen, mount the GTZ overhanging from the panel, so that the air can flow vertically on the heat­sink without obstables.
• Maximum surrounding air temperature 40°C (for UL).
• Open type equipment
• max. voltage limits and derivative of transients in line, for which the solid state unit has internal protection devices.
• presence of dispersion current < 10mA (max. value with rated voltage and jun­ction temperature of 125°C).
Limits of use
• dissipation of thermal power of device with restrictions on temperature of instal­lation site.
• requires exchange with outside air or an air conditioner to transfer dissipated power outside the panel.
• installation requirements (distances between devices to guarantee dissipation under conditions of natural convection)
TECHNICAL DATA OF THE MAIN CIRCUIT
Model Imax Ie (*)
[Arms]
GTZ 25/400 3x25 250 450 GTZ 25/480 3x25 400 645 GTZ 40/480 3x40 600 1010 GTZ 55/480 3x55 1150 6600 GTZ 40/600 3x40 600 1010 GTZ 55/600 3x55 1150 6600
(*) Ie = Nominal current (Standard CEI EN 60947-4-3)
Non-repetitive
overcurrent t=20ms [A]
DIMENSIONS
Models: GTZ-25/xx-x-x (25A) Models: GTZ-40/xx-x-x, GTZ-55/xx-x-x (40 and 55A)
127mm 127mm
30mm
L1 L2 L3
GTZ 25/400-0-1
AC51: 25A 400Vac AC53a: 5A 50/60Hz
T1 T2 T3
L1L2 L3 A1+
T1 T2 T3 A2-
Alarm
On
B1
B2 A1
5..32 Vdc
A2
L1 L2 L3
GTZ 40/600-0-1 VEN-90 fan:230Vac
AC51: 40A 600Vac AC53a: 8A 50/60Hz
T1 T2 T3
L1L2 L3 A1+
T1 T2 T3 A2-
Alarm
On
B1
B2 A1
5..32 Vdc
A2
I2t
[A2s]
8
30mm
100mm
Depth:
- Models GTZ-xx/xx-D-x : 150 mm
- Models GTZ-xx/xx-A-x : 158 mm