MAX
MAX
SOLID STATE RELAY - ACCESSORIES
> 100
> 100
> 20
> 20
> 20
> 20
> 20
GQ, GS, GZ, GT, GD, GTF, GFW ACCESSORIES
HEATSINKS
DESCRIPTION
Different models of heatsinks have been designed and tested to meet size and dimension needs.
How to choose a heatsink
Set max. air temperature inside the panelboard (Tmaxa)
Set max. operating current: Imax = Inom. load + 10%
Draw on the “graphs” Tmax
Imax points.
a,
INSTALLATION
In order to obtain best reliability, it is important to install a heatsink correctly inside the panel, to reach an adequate thermal exchange between the device and the surrounding air in natural convection conditions.
How to install it correctly:
Mount it vertically ( max. 10° inclination from the vertical axis)
Vertical distance between a heatsink and the panel wall: 100 mm at leas.
Horizontal distance between a heatsink and the panel wall: 20 mm at least.
Vertical distance between two heatsinks: 300 mm at least.
Horizontal distance between two heatsinks: 40 mm at least.
Choose the smallest heatsink (starting from upwards), which
point [Tmaxa Imax] is in the gray working area of dissipation curves
Respect installation distances
10ϒ
10ϒ
Channel
Channel
Fig. 1
AIR
FAN
> 20
> 40
> 40
Channel
Channel
> 40
> 20
ARIA
FAN
> 100
> 100
AIR
> 20
> 20
> 20
FAN
> 20
> 20
> 20
> 20
> 20
> 20
Channel
Channel
> 20
> 20
> 20
> 20
> 20
> 20
Channel
> 20
> 20
Channel
> 20
> 20
Channel
Channel
VFAN
> 100
> 300
> 300
AIR
Page 2
DISSIPATION CURVES
Effective current controllable based on room temperature
DIS 15G
DIS 25G
DIS 25GD
current (A)
Controlled effective
current (A)
Controlled effective
current (A)
Controlled effective
15
12
9
6
3 0
25
20 15
10
5
0
25
20 15
10
5
0
20 40 60 80 90
30 50 70 100
Room temperature (°C)
20 40 60 80 90
30 50 70 100
Room temperature (°C)
20 40 60 80 90
30 50 70 100
Room temperature (°C)
h = 57mm
= 4,1°C/W
R
th
(*)
h = 100mm
= 3,12°C/W
R
th
(*)
h = 100mm Rth = 2,8°C/W (*)
40,25
35
24
65
54,5
35
DIS 40G
DIS 50G
DIS 60G
50
40
30
20
current (A)
10
0
Controlled effective
20 40 60 80 90
30 50 70 100
Room temperature (°C)
50
40
30
20
current (A)
10
0
Controlled effective
20 40 60 80 90
30 50 70 100
Room temperature (°C)
80
60
40
20
current (A)
0
Controlled effective
20 40 60 80 100
30 50 70 90
Room temperature (°C)
With fans
h = 100mm Rth = 1,90°C/W (*)
h = 100mm R
= 0,83°C/W
th
(*)
h = 100mm
= 0,66°C/W
R
th
(*)
100
35
100
60
100
80
Page 3
DIS 90G
DIS 908
120
100
80
60
40
current (A)
20
Controlled effective
030507090
20 40 60 80 100
25
20 15
10
current (A)
5 0
Controlled effective
20 40 60 80 90
Room temperature (°C)
30 50 70 100
Room temperature (°C)
With fans
h = 100mm Rth = 0,56°C/W (*)
h = 80mm Rth = 0,7°C/W (*)
100
126,6
100
126,6
With fans
h = 100mm
= 0,56°C/W
R
th
(*)
100
126,6
DIS 910
60
50
40
30
20
current (A)
10
Controlled effective
030507090
20 40 60 80 100
Room temperature (°C)
Should the stated point [Tmaxa Imax] be outside the working area, it is necessary to equip the heatsink with a fan and a safety thermostat.
N.B. The operating point has not to be outside the delimited area.
- DIS908/910 heatsinks are suitable for three-phase solid state relays of GZ series.
- Controlled three-phase effective current refers to the used line current of three-phase load.
- Heatsinks used with a cooling fan should be equipped with safety thermostat, so that the solid state relay can be switched off in case of fan failure.
(*) Data surveyed with 40°C ambient temperature and heatsink in vertical position surrounded by 15 cm free space; natural convection; contact surface with the heating
element = ~ 8cm
2
[38mmx 20mm]
HEAT SINKS - ORDER CODE - AVAILABLE MODELS
CODE DESCRIPTION (dimensions HxLxP) for SSR type equipment
DIS-25G heatsink in extruded aluminium 100x24x65 GS 15/25A M4 screws for relay fixing DIN rail
mounting
DIS-25GD heatsink in extruded aluminium 100x35x54 GS ≤ 40A / GD M4 screws for relay fixing DIN rail
mounting
DIS-40G heatsink in extruded aluminium 100x35x100 GS ≤ 40A / GD40A M4 screws for relay fixing DIN rail
mounting
DIS-50G heatsink in extruded aluminium 100x60x100 GS ≤ 50A / GT / GQ M5 screws for relay fixing DIN rail
mounting
DIS-60G heatsink in extruded aluminium 100x80x100 GS ≤ 50A / GT / GQ
DIS-90G heatsink in extruded aluminium 100x126x100 GS ≤ 50A / GT / GQ
DIS-908 heatsink in extruded aluminium 80x126x100 GZ
DIS-910 heatsink in extruded aluminium 100x126x100 GZ
DIS-25G-1M heatsink in extruded aluminium for group
mounting SSR, with DIS-25G profile
DIS-40G-1M heatsink in extruded aluminium for group
mounting SSR, with DIS-40G profile
DIS-50G-1M heatsink in extruded aluminium for group
mounting SSR, with DIS-50G profile
DIS-60G-1M heatsink in extruded aluminium for group
mounting SSR, with DIS-60G profile
DIS-90G-1M heatsink in extruded aluminium for group
mounting SSR, with DIS-90G profile
Page 4
POWER SOLID STATE RELAYS ACCESSORIES
THERMOSTAT
DESCRIPTION
Safety thermostat is expressly designed to prevent overtemperature. Thanks to the miniaturized case the thermal answer is excellent. Furtheron, the thermostat is a very good thermal protection, as it can be mounted very near to the critical point which has to be controlled. When it is connected in series to control voltage, the thermostat disenergises the relay as soon as the critical operating temperature is reached. Relay is energised again when temperature drops underneath the critical value (about 90°C). The thermostat is normally closed and opens when temperature exceedes 90°C (with automatic reset). Connection in series with the input control is suggested. TGRZ is installed in one of the two slots of the GZ three-phase solid state relay case. TGR is fixed by means of a small bracket and of a screw (enclosed).
The VIR-1 thermostat is supplied as a spare part for:
W21x ≥ 150A solid state power units.
INSTALLATION
TGRZ
TGR
ORDER CODE - AVAILABLE MODELS
T-GR (includes fastening bracket) T-GRZ (for GZ)
VIR-1 (for W21x ≥ 150A)
SOLID STATE RELAY ACCESSORIES
VARISTORS (MOV)
Spark Suppressors for Solid State Relay Protection
DESCRIPTION
MOV (metal-oxide-varistor) is an overvoltage protection device which improves the reliability of solid state relays when functioning
ORDER CODE
RV03
WORKING VOLTAGE (V)
120-290 Vac
RV04
RV05
291-400 Vac
401-500 Vac
Page 5
HEATSINKS ACCESSORIES
FANS
DESCRIPTION
An additional fan, applied to the heatsink of a solid state relay, improves its dissipation performance and allows the solid state relay to work at higher ambient temperatures with the same current. Fan installation benefits are shown (dashed) by the dissipation curves of the different heatsinks.
ORDER CODE - AVAILABLE MODELS
Code Description Mechanical
VEN-60 Fan kit 24Vdc, 4W 60x60x25
VEN-90
VEN-91
VEN-92 Fan kit 24Vdc, 4W 80x80x25
Fan kit 230Vac, 14W, 50Hz 80x80x40
Fan kit 115Vac, 14W, 50Hz 80x80x40
predisposition for
heatsink type
DIS-50G DIS-60G
DIS-90G
DIS-910 DIS-908
DIS-90G
DIS-910 DIS-908
DIS-90G
DIS-910
ACCESSORIES GTF / GFW
ORDER CODE - AVAILABLE MODELS
Equipment For SSR
hand guard nr. 4 screws nr. 4 plastic fastening rivets for direct
attachment to heatsink
hand guard nr. 4 M4 screws nr. 4 notched washers nr. 4 plastic fastening rivets for direct
attachment to heatsink
hand guard nr. 4 M4 screws nr. 4 notched washers nr. 4 plastic fastening rivets for direct
attachment to heatsink
hand guard nr. 4 M4 screws nr. 4 notched washers nr. 4 plastic fastening rivets for direct
attachment to heatsink
type
GTS 120A GTT 120A
GTZ ≥ 40A
GTS 120A GTT 120A
GTZ ≥ 40A
GTS 120A GTT 120A
GTZ ≥ 40A
Code Description Mechanical
VEN-60
VEN-62 Fan 24Vdc, 4W, 60x60
VEN-63 Fan 24Vdc, 4W 60x60
VEN-92
GRI-4 Fan grill
FLT-4 Filtre for fan
Fan kit 24Vdc, 4W 60x60x25
Fan kit 24Vdc, 4W 80x80x25
predisposition for
heatsink type
DIS-60G
To be includedin the grid
GRI-4
To be includedin the grid
GRI-4
DIS-90G
Equipment For SSR type
hand guard D60 nr. 4 screws M2 + notched washers nr. 4 plastic fastening rivets cable with ferrules
cable wit 3 pole connector
cable wit 3 pole connector
hand guard D80 nr. 4 M4 screws + notched washers nr. 4 plastic fastening rivets cable with ferrules
GTF40, 50 El.Fuse
GTF150 GFW40,60,100,150
GTF200, 250 GFW200,250
GTS 120A GTF60 El.Fuse
GTF150,200, 250 GFW150,200,250
GTF150,200, 250 GFW150,200,250
Page 6
ACCESSORIES SUPPORT FOR DIN BAR
PANEL ATTACHMENT SUPPORT
DIN 2 DIN 5
DIN 4
PAN 1
1886001
ORDER CODE - AVAILABLE MODELS
Code Description For SSR /
Equipment
Heatsink type
DIN-2 support for attachment to DIN bar
DIN-4 support for attachment to DIN bar with spring
GTS 15/25A DIS15G, DIS25G
W211 25/40/75/100/150A W212 25/40/75/100/150A
fastening screws
fastening screws
GTS, GTD, GTT, GTZ, DIS15G, DIS25GD,
DIN-5 support for attachment to DIN bar with spring
DIS25G, DIS40G,
fastening screws DIS50G, DIS60G, DIS90G, DIS908, DIS910
F19672 socket for relays with attachment to DIN bar GTS-L 5/10/15A fastening screws
nr. 2 plastic supports
PAN-1 kit attachment to panel GTS, GTT,
nr. 2 screws
nr. 4 washers
1886001 kit attachment to panel Wattcor series
Socket
F19672
SOLID STATE RELAY ACCESSORIES
COVERS FOR SOLID STATE RELAYS
ORDER CODE - AVAILABLE MODELS
Code Description
COP-GS-0 Pad-printed cover for GS-T 10A, 20A and GS 15A, 25A.
COP-GS-1
COP-GS-2
COP-GD-0 Pad-printed cover for GD40.
COP-GTS-0 Pad-printed cover for GTS-T 10A, 20A and GTS 15A, 25A.
COP-GTS-1 Pad-printed cover for GTS-T 25A and GTS 40A.
COP-GTS-2 Pad-printed cover for GTS 50A, 60A, 75A, 90A, 120A.
COP-GTD-0 Pad-printed cover for GTD-25
COP-GTD-1 Pad-printed cover for GTD-40
COP-GT-0 Pad-printed cover for GT 25A, 40A, 50A, 60A, 75A, 90A, 120A.
COP-GTT-0 Pad-printed cover for GTT 25A, 40A, 50A, 60A, 75A, 90A, 120A.
COP-GTS-L-0 Cover for GTS-L5
COP-GTS-L-1 Cover for GTS-L10 / GTS-L15
BBR Protective cover for RA single-phase solid state relays
Pad-printed cover for GS-T 25A and GS40A.
Pad-printed cover for GS 50A, GS 60A, GS 75A, GS 90A, GS 120A.
Page 7
SOLID STATE RELAY ACCESSORIES
FUSES AND FUSE HOLDERS
DESCRIPTION
These fuses ensure the maximum safety in solid state relay applications. Fuses with a very high cutoff power are used for this kind of applications.
MODEL SELECTION
GS-L / GTS-L / GTS-T / GTS / GS / GS-T / GTD / GTT (single-phase with antiparallel thyristor or Triac)
FUSES AND FUSE HOLDERS
Type relay i²t Nominal
voltage
Size Dimensions
(mm)
Fuse
order
Fuse holder
order code
Notes
code
GS-L5 / GTS-L5 / GTS-L4-5
GS-L10 / GTS-L10 / GTS-L4-10
GS-L15 / GTS-L15 / GTS-L4-15
GS-T 10 / GTS-T 10 72 230 10A 10x38 FUS-010 PF-10x38 plug-in
GS-T 20 / GTS-T 20 315 230 25A 10x38 FUS-025 PF-10x38 plug-in
GS-T 25 / GTS-T 25 315 230 25A 10x38 FUS-025 PF-10x38 plug-in
45
100
180
230 440
230 440
230 440
5A 10x38 FUS-06-L PF-10x38
10A 10x38 FUS-10-L PF-10x38
15A 10x38 FUS-16-L PF-10x38
plug-in
plug-in
plug-in
GQ / GS-L / GTS-L / GTS-T / GTS / GS / GTD / GTT / GTF (single-phase with antiparallel thyristor or Triac)
FUSES AND FUSE HOLDERS
Type relay i²t Nominal
voltage
230
GQ / GTS / GS 15 450
GTS / GS / GTT /
GQ / GT / GTD 25
GTF25
GTS / GS / GTT / GT / GTD 40 1010
GTF40 / GTF50 1800
GTS / GS / GTT /
GQ / GT 50
GTF60 6600
GTS / GS / GTT / GT 60 GTF75 6600
GTS / GS / GTT / GT 75 8000
GTS / GS / GTT / GQ / GT 90 11200
GTS / GS / GTT / GT 120 GTF90 / GTF120 11200
(*) PF for fuseholders: LEGRAND, PFI for fuseholders: ITALWEBER
645 450
480 16A 10x38 FUS-016 PF-10x38 plug-in
230 480 600 25A 10x38 FUS-025 PF-10x38 plug-in
230 480 40A 14x51 FUS-040 PF-14x51 plug-in
480 600 50A 22x58 FUS-050 PF-22x58 plug-in
230 480 600 63A 22x58 FUS-063 PF-22x58 plug-in
230 480 600 80A 22x58 FUS-080 PF-22x58 plug-in
230 480 80A 22x58 FUS-080 PF-22x58 plug-in
230 480 600 100A 22x58 FUS-100 PF-22x58 plug-in
230 480 600 125A
Size Dimensions
(mm)
0-0-0-TN/80
100x51x30 FUS-125N
Fuse
order
code
Fuse holder
order code
(*)
337092-
UR400A@1000V
PF-DIN no plug-in
Notes
Page 8
MODEL SELECTION
GTZ, GZ (three-phase with antiparallel thyristor)
FUSE EXTRARAPID / FUSE HOLDER
Relay i^2t Nominal
voltage
Size Dimensions
(mm)
Fuse
order
Fuse holder
order code
Notes
code
GZ 10A 100 400 10A 10x38 FUS-10-L PF-10x38 plug-in
450
GTZ, GZ 25A
GTZ, GZ 40A 1010
GTZ, GZ 55A 6600
645
400 480 25A 12x32 FUS-025 PF-10x38 plug-in
480 600 40A 14x51 FUS-040 PF-14x51 plug-in
480 600 63A 22x58 FUS-063 PF-22x58 plug-in
W21X / W312 / W401 (single-phase with antiparallel thyristor)
FUSE EXTRARAPID / FUSE HOLDER
Relay i^2t Nominal
voltage
Size Dimensions
(mm)
Fuse
order
Fuse holder
order code
Notes
code
W21x / W312 25A 1800 660 50A 22x58 FUS-050 in the product plug-in
W21x / W312 40A 11200 660 63A 22x58 FUS-063 in the product plug-in
W21x 75A 14450 660 100A 22x58 FUS-100 in the product plug-in
W21x 100A 86200 660 250A 27x60 FUS-250 in the product plug-in
W21x 150A 86200 660 250A 27x60 FUS-250 in the product plug-in
W21x 250A 200000 660 450A - FUS-450N - no plug-in
W21x 400A 1125000 660 630A - FUS-630N - no plug-in
W21x 600A 1125000 660 900A - FUS-900N - no plug-in
W401 40A 11200 460 63A 22x58 FUS-063 in the product plug-in
W401 100A 86200 460 250A 27x60 FUS-250 in the product plug-in
Relay i^2t Nominal
GFW40 10000
GFW60 12000
GFW100 18000
GTF150 GFW150 125000
GTF200 GFW200 320000
GTF250 GFW250 320000
GTF >120 / GFW (with antiparallel thyristor)
FUSE EXTRARAPID / FUSE HOLDER
Size Dimensions
voltage
480 600 80A
480 600 125A
480 600 160A
480 600 200A
480 600 450A
480 600 450A
(mm)
SI 000 DIN80
100x39x20 FUS-080 S in the product plug-in
SI 000 DIN80
100x39x20 FUS-125 S in the product plug-in
SI 000 DIN80
100x39x20 FUS-160 S in the product plug-in
SI 000 DIN80
100x39x20 FUS-200 S in the product plug-in
SI 000 DIN80
100x65x30 FUS-450 S in the product plug-in
SI 000 DIN80
100x65x30 FUS-450 S in the product plug-in
Fuse
order
code
Fuse holder
order code
Notes
Page 9
ORDER CODE - AVAILABLE MODELS
FUSES FUSEHOLDERS (*)
FUS-06-L FUS-050 FUS-900N PF 10x38
FUS-010-L FUS-063 FUS-080S PF 14x51
FUS-016-L FUS-080 FUS-125S PF 22x58
FUS-010 FUS-100 FUS-160S PF DIN (100x51x30)
FUS-016 FUS-125N FUS-200S
FUS-025 FUS-250 FUS-400S
FUS-030 FUS-450N FUS-450S
FUS-040 FUS-630N
(*) PF for LEGRAND fuseholders, PFI for ITALWEBER fuseholders
• Power transformer and isolation
TRAFO - 1
TRAFO - 1B
TRAFO - 5
TRAFO - 5B
Transformer for galvanic isolation of power supply.
Dimensions TRAFO - 1 / TRAFO - 1B L: 58mm B: 47mm H: 36mm
Dimensions TRAFO - 5 / TRAFO - 5B L: 67mm B: 52mm H: 45mm
Order code
TRAFO - 1: 3VA transformer, 230/24Vac
TRAFO - 1B: 3VA transformer, 24/24Vac
TRAFO - 5: 10VA transformer, 230/24Vac
TRAFO - 5B: 10VA transformer, 24/24Vac
• Current transformer
Hole for 2.9 x 9 self-threading screws
5,5
920 19
4430
1010
12
48
152050 9640
1
88
27
13
50 /0.05 A
38
5,5
2
In
20
These transformers are used for currents of 50/60 Hz. The main characteristic of these transformers is the high number of turns in the secondary.
This provides a very low secondary current, suitable for an electronic measurement circuit.
The secondary current can be measured as a voltage on a resistor.
Order code
330200 IN = 50Aac OUT = 50mAac
330201 IN = 25Aac OUT = 50mAac
Page 10
• Ground terminal for heat sinks
The ground terminals attached to GEFRAN heat sinks allow connection of the ground terminal with the screws supplied in the kit.
Type
TERM-25
TERM-40
TERM-60
* (WxD) = Width (mm) x Depth (mm)
Ground terminal
Contact area (WxD) *
Screw type
9x12
M5 M4 DIS-25G
11,5x12
M5 M4
14x16
M5 M5
Screw type on heat sink side
Heat sink
DIS-40G
DIS-25GD
DIS-50G DIS-60G DIS-90G
SOLID STATE RELAYS ACCESSORIES
THERMOCONDUCTIVE PASTE
THERMOCONDUCTIVE ADHESIVES
IDENTIFICATION LABELS
ORDER CODE
Code Description
SIL-1 Silicone thermoconductive paste for coupling the power module to the heat sink. 100 g tube.
SIL-GQ
SIL-GS40
SIL-GS50
LAB-1 Kit with 20 plastic identification labels for GS / GS-T / GTS / GTS-T / GTT / GT / GD / GTD power solid state relays
Graphite film 35x55mm for solid state relays GQ series. Thickness 0,12mm. 2,1W (m*K).
200x240mm sheet with n° 25 adhesives.
Graphite film 20x55mm for solid state relays GS ≤ 40A series. Thickness 0,12mm. 2,1W (m*K).
200x240mm sheet with n° 45 adhesives.
Graphite film 30x56mm for solid state relays GS ≥ 50A series. Thickness 0,12mm. 2,1W (m*K).
200x240mm sheet with n° 30 adhesives.
SOLID STATE RELAYS ACCESSORIES
CONNECTORS
ORDER CODE
Code Description
MORS1 Two-pin spring connector, plug-in, for GQ control signal
MORS2 Two-pin double spring connector, plug-in, for GQ control signal
MORS3 Two-pin screw connector, plug-in, for GQ control signal
Page 11
CONNECTORS FOR INPUTS / OUTPUTS
GTF and GFW
PRODUCT DESCRIPTION
Series of connectors for Geflex inputs/outputs/power supply
ORDER CODE
Available for GTF25-120A
9-pin connector for power and control (J1) COUT4-9
Available for GTF>120A
4-pin connector for outputs (J1) COUT4-4
3-pin connector for power supply (J2) CSIG4-3
4-pin connector for digital input (J3) CSIG4-4
4-pin connector for analog input (J4) COUT4-4
2-pin connector for line voltage (J8) CSIG2
Available for GFW
9-pin connector for alarm outputs and cooling (J1) COUT4-9
3-pin connector for power supply (J2) CSIG4-3
4-pin connector for digital input (J3) CSIG4-4
4-pin connector for analog input (J4) CSIG4-8
4-pin connector for analog input control (J5) COUT4-4
4-pin connector for analog input main (J6) COUT4-4
2-pin connector for fan power (J7) CSIG4-2
2-pin connector for line voltage (J10) CSIG2
Page 12
Accessories for GTF / GFW
CONFIGURATION KIT
KIT PC RS232 / TTL
KIT PC RS232 / RS 485
Conguration kit for standard GTF (via the TTL port) by means of PC with RS232
serial line (Windows environment). Lets you read or write all of the parameters of a single GTF A single software for all models
• Easy and rapid conguration
• Saving and management of parameter recipes
• On-line trend and saving of historical data
Component Kit:
- Connection cable PC RS232 ‹--› GTF port TTL
- CD SW GF Express installation
ORDER CODE
GF_eXK-0-0-0....................................Cod. F043956
Kit for GFW and GTF conguration with Modbus RS485 serial option by PC / PLC
equipped with RS232 serial (Windows environment). Lets you read or write all of the parameters of a single GTF / GFW A single software for all models
• Easy and rapid conguration
• Saving and management of parameter recipes
• On-line trend and saving of historical data
Component Kit:
- Connection cable PC RS232 ‹--› GTF / GFW RS485 port
- Serial line converter
- CD SW GF Express installation
KIT PC USB / RS485 or TTL
ORDER CODE
GF_eXK-1-1-0....................................Cod. F043957
kit for PC via the USB port (Windows environment) for GTF standard conguration (TTL port) for conguration of GFW and GTF with the RS485 option
Lets you read or write all of the parameters of a single GTF/GFW A single software for all models
• Easy and rapid conguration
• Saving and management of parameter recipes
• On-line trend and saving of historical data
Component Kit:
- Connection cable PC USB‹--› GTF TTL port
- Connection cablePC USB‹--› GTF/GFW RS485 serial port
- Serial line converter
- CD SW GF Express installation
ORDER CODE
GF_eXK-2-0-0....................................Cod. F049095
The human/machine interface (HMI) is simple, intuitive, and very practical thanks to the optional GFW – OP programming keyboard. Lets you read or write all of the parameters of a single GFW-M module. Connected with 9-pin D-SUB connector and housed in the front panel of the GFW-M by means of a magnetic plate.
• Alphameric display: 5 lines x 21 characters.
• Keys to display variable and set parameters.
• Magnetic housing
ORDER CODE
GFW - OP....................................Cod. F051664
Page 13
FIELDBUS CARD
ORDER CODE
Cards for Modbus RTU protocol GFX4-MOD
Cards for Profibus DP protocol GFX4-PROFI
Cards for CANopen protocol GFX4-CAN
Cards for DeviceNet protocol GFX4-DNET
Cards for Ethernet Modbus TCP protocol GFX4-ETH
Cards for Ethernet IP protocol GFX4-ETH1
Cards for EtherCAT protocol GFX4-ETH2
Cards for Profinet protocol GFX4-ETH4
Cards for Real Time Ethernet protocol GFX4-ETH5
COMMUNICATION CONNECTORS / ADAPTERS
PRODUCT DESCRIPTION
Series of connectors for all field bus types (Modbus, Profibus, CANopen, DeviceNet), to facilitate wiring of the communication cable.
Adapters to bring 9 pin SUB connector to front.
ORDER CODE
Connector for Geflex Master Modbus with cover and inside terminals CON-M-90
Connector for Geflex Master Profibus with cover and inside terminals CON-P-90
Connector for Geflex CANopen with cover and inside terminals CON-C-90
Connector for DeviceNet with cover and inside terminals CSIG-5
Connector for serial1 (local bus) type 4p4c/RJ10 CRJ10
90° adapter for 9 pin SUBD male connector (Geflex Master CANopen) AD-9M
90° adapter for 9 pin SUBD female connector (Geflex Master Modbus/Profibus) AD-9F
Page 14
CABLES
PRODUCT DESCRIPTION
Series of cables for field bus and to extend connections between Geflex GFXS1/S2.
ORDER CODE
Shielded cable, 1 pair, 22 AWG, L = 1 m Modbus type 2x0,35 CABLE
Shielded cable, 1 pair, 22 AWG, L = 1 m Profibus type PROFIBUS CABLE
Shielded cable, 2 pairs, 22 AWG, L = 1 m CANopen type CANBUS CABLE
4-pin telephone cable CV4-RJ10
Cavo l = 0,3m per collegamento seriale Modbus (RJ10) (bus locale) GFX4 <---> GFX4 e GTF/GFW <---> GTF/GFW CV4-03
Cable l = 0.3 m for Modbus serial connection (RJ10) (local bus) GFX4 <---> GFX4 and GTF/GFW <---> GTF/GFW CV4-1
Cable l = 1 m for Modbus serial connection (RJ10) (local bus) GFX4 <---> GFX4 and GTF/GFW <---> GTF/GFW CV4-2
Cable l = 5 m for Modbus serial connection (RJ10) (local bus) GFX4 <---> GFX4 and GTF/GFW <---> GTF/GFW CV4-5
DTS_ACCESSORI-SSR_05-2013_ENG