Gefran GFX-4 Data Sheet

Main application
• Packaging
• Extrusion
• Thermoforming
• Injection moulding
• Textile
GFX-4
4 LOOP MODULAR POWER CONTROLLER
Main features
4 independent loop control unit. Compact, ready to use, equipped also with fieldbus interface.
Unit consisting of:
• Controller
• 30, 60, 80kW solid state relay
• Current transformers (one or four)
• Fuses-holder (option)
• 4 universal main inputs
• 4 heat/cool independent PID
• 4 main output internally wired to the SSR
• 4 auxiliary analog inputs (option)
• 4 configurable output (option): relay / logic / TRIAC / continuous
• 2 configurable relay alarm output
• 2 digital inputs
• Standard digital communication: Modbus RTU
• Optional Fieldbus communication: Profibus DP, CANopen, DeviceNet, Modbus RTU, Ethernet Modbus TCP, Ethernet IP, EtherCAT, ProfiNET
• DIN rail or panel mounting
PROFILE
GFX4 is a four independent loop control­ler, designed to manage electrical power. GFX4 is a compact unit bounding different technological elements like:
• controller
• solid state relay
• current transformers
• fuses-holders (option) The final result is a cost saving in terms of space and cabling. GFX4 consisting of:
• power management unit
• analog and digital inputs,
• analog and digital outputs
• standard digital communication
• integrated solid state relays
• fuses-holder (option) Geflex controls autonomously the four loop controllers, furnishing a complete diagnostics like the loaded current, the control of the zones, the alarms state. A specific step by step software tool has been develop in order to assist the pro­duct configuration based on the different applications. Communication with the outside is of pri­mary importance. Geflex dialogs with the operator terminals according to the most popular protocols: from the simple and efficient Modbus to, by a second optional fieldbus communi-
cation, the by-now indispensable Profibus DP, CANopen, DeviceNet, Modbus RTU, Ethernet Modbus TCP, Ethernet IP, EtherCAT, ProfiNET.
The product’s furnished with a standard
configuration, simple and quickly to modify. The assignment of different functions to the outputs is very simple.
MODELS
(see table in order code)
3 different sizes, depending on the elec­tric power managed, are available.
GFX4 80 Maximum contemporaneous power up to 80kW@480V. Each zone could reach up to 19,2 kW. This limit could be extend to 23,7 kW using the “smart power management” (not all the zone contemporaneous). Nominal current 40A for zone, not con­temporary maximum 57A
GFX4 60
Maximum contemporaneous power up to 60kW@480V. Each zone could reach up to 15,3 kW. Nominal current 32A for zone Fuse holder could be provide as an option.
GFX4 30
Maximum contemporaneous power up to 30kW@480V. Each zone could reach up to 7,6 kW. Nominal current 16A for zone Fuse holder could be provide as an option.
INPUTS
Process analogue
4 universal process input could accept: thermocouple, thermoresistance, current and tension linear. The type could be choose by software and no external converting device are required.
Digital
2 digital input. The functionality could be selected within a wide range including setpoint selection, MAN/AUTO, alarm memory reset and many other.
Incorporated CT
From 1 to 4 CT control each zone and the relative alarm control is start up (HB..).
Auxiliary analogue (option)
4 further analogue inputs are available, typically for external current transformer reading.
OUTPUTS
By default a different meaning is applica­ble.
POWER
Power is controlled with double SCR in anti-parallel, zero crossing switching prin­ciple, with configurable proportional cycle time. Different load connection are available: monophase, dualphases, three-phases.
FUSES (option)
The fuses are orderable on the GFX4 30KW and 60kW model. Thanks to this, you save time, wiring is simplified, and dimensions in the panel are reduced.
PROGRAMMING
The Geflex modules can be programmed:
• using GFX-OP
• using Winstrum tool software
• using Industrial PC or PLC.
The software can be used to define the state of alarm outputs or a preset power level to be supplied in case of broken probe. This assures continuity of service in the individual zone.
Tuning
• Self-tuning: calculation of PID parameters at system art.
• Auto-tuning continuous: continuous adjustment of PID
• Autotuning one-shot: output modulation and event-driven automatic PID parame­ters re-calculation
Special functions
• Soft-start: power parcellization time­based
• Software Off: disabling of the control, outputs are turned off
• Inputs\outputs: direct management of inputs/outputs, independently from inter­nal firmware
• Simulation of four independent Geflex units.
Output alarms configurable via software.
Heating control
For each zone an heating control internally connected to power unit is present, then no further connections needed between power unit and controller.
Cooling control (option)
For each zone a cooling control is present 4 types of outputs are available: relay, logic, triac, continuous. A current transfor­mer is furnished with TRIAC output.
Alarms
Two relay output configurable as minimum and maximum alarm are available for each unit.
LEDs
Eight monitoring led are available in order to provide diagnostic information.
RN RUN stet of the CPU ER Error DI1 DI1 digital input state DI2 DI2 digital input state O1 Outupt 1 state O2 Outupt 2 state O3 Outupt 3 state O4 Outupt 4 state
FUNCTIONS
Control
The Geflex control algorithm works with any type of thermal process. Different control modes are available: from a simple ON/OFF control to PID single or double acting heat/cool (for cooling, simply indicate the fluid used). Sophisticated and efficient automatic tuning algorithms for control parameters provide precise process control without the presence of an operator.
Alarms
There are 8 alarm assignable to each single canal or to all (AND / OR logic) and configurable as absolute, relative, direct, reverse, window, latching or not, inhibit at power-on.
Diagnostics
Geflex assures efficient process monito­ring from a thermal and electrical point of view, allowing the operator to foresee bre­akdowns or malfunctions and take timely action (for example, in case the tempe­rature safety limit is exceeded, broken probe, load fault). The LBA alarm precisely checks the con­trol loop, while the on-board current tran­sformer (one always present, four availa­ble in option) lets you directly monitor load and trip the HB alarm in case of current failure or SSR in short circuit. Detection of short circuit or opening of input probe, open loop alarm (LBA), inter­rupted load alarm (HB). Over temperature alarm
STANDARD DIGITAL COMMUNICATION
The product is furnished with standard digital communication [PORT 1] used as GFX4 connection to a HMI or Industrial PC. Also by a dedicated connector (10 pins)
it’s possible to connect the actual range
of Gefllex. A second standard digital communication (PORT 2) configurable by most popular protocol: CANopen DeviceNet Profibus DP Modbus RTU Ethernet Modbus TCP Ethernet IP, EtherCAT, ProfiNET
is available as option.
Net address
Assigned by two rotative selectors.
GENERAL DESCRIPTION
3
4
5
13
6
2
12
1
7
11
10
8
9
8
14
1. DIN rail frontal
2. power terminal: screws
3. power terminal
4. ventilation grid (attention NOT obstruct)
5. hook/release device back DIN rail
6. hole for screws
7. microswitchs of configuration
8. standard digital communication
9. rotative selector switch
10. connectors J1, J2, J3, J4
11. fuses-holder (only for 30KW and 60KW models)
12. fuses-holder terminal (F1, F2, F3, F4)
13. power terminal (U1, U2, U3, U4)
14. ventilation grid (attention NOT obstruct)
DIMENSIONS - INSTALLATION
82
109,5
92,5 35 19,5
92,5 35 19,5
147
140
4
140
140
147
42140
140
111,5
182
195
101,5
109,5
4132
101,54
132 4