Gefran CM Data Sheet

CM
LOAD CELL FOR COMPRESSION APPLICATIONS
MECHANICAL DIMENSIONS
Main features
• Range of measurement: from 100 to 50.000 Kg
• Accuracy class: 0,2%
• All stainless steel construction
• Corrosion resistant
• Grade of protection: IP67 (DIN 40050)
CM series load cells are strain gauge transducers used to measure loads in static and dynamic applications, in compression, with high accuracy. They are machined from a single block of metal, so the primary sensing element, the mountings and the case contain no welds allowing smaller dimensions and an enhanced grade of protection. The configuration of the point of measurement, with 8 strain gauges, reduces errors caused by imperfect applications of the load. Typical applications of load cells connected in parallel are: silos, hoppers, large weighing platforms. The stainless steel construction is suitable for use in aggressive environments in the chemical and petrochemical industries.
ø A ø B ø C ø D E H K L L1 L2 ø M ø N R VITI Nm*
TECHNICAL DATA
0,2%
100...50.000 Kg 2mV/V
<± 0,2% FSO
< ± 0,2% FSO
< ± 0,06% FSO
< ± 1% FSO
80%FSO ± 1%
< ± 0,01% FSO°C < ± 0,01% FSO°C < ± 0,01% FSO°C
700 Ohm 700 Ohm
> 10 GOhm
10 V 15 V
-10...+50°C
-20...+60°C
-30...+80°C 130% Ln 100% Ln
150% Ln
> 300% Ln
< 0,2 mm
Cable: IP67
Connector: IP65
VPT02A10-6PT2
6x0,25 / 5 m.
Stainless steel
Accuracy Nominal full scale load (Ln)
Nominal output at FSO Output tolerance at Ln
Combined errors: Non linearity Histeresis, Repeatibility
Creep (after 30 min. at Ln) Zero load out of balance signal Calibration signal * Thermal drift in Sensitivity
compensated Zero range Calibration
Nominal input resistance Nominal output resistance Isolation resistance Nominal supply voltage Maximum supply voltage Compensated temperature range Maximum temperature range Storage temperature range Permitted static load Permitted dinamic load Maximum applicable load Rupture load
Maximum elastic deformation at Ln Grade of protection (DIN40050)
Electr. connections: Connector
Screened cable
Elastic element material
* The exact value is indicated on the instrument nameplate
100 2000
87
6,5
10,5
100
6 11,7 15,7 45,7
30
13,5
20 24 30
6XM6
9
3500 7000
98,5 10,5 16,5
120
10 17,5 21,5 51,5
30 13,5
24
30
30
6XM10
60
10000 30000
102,2
13 19
126
12,5
­14 54 40 17 35
­50
6XM12
100
50000
125
17 25
155
16,5
­16 77 61 27 45
-
100
6XM16
200
Ln (Kg)
Dimensions mm. (± 0,1) * Recommended torque with UNI 5931 screws of resistance class 10.9 according to UNI 3740.
LOAD INTRODUCTION DIRECTION
BALL R
BALL R
ELECTRICAL CONNECTIONS
CONVERSION TABLE
If the transducer is supplied complete with prewired connection cable, the colour code is that indicated in the table.
Cells connected in parallel
In systems that use several cells, the parallel connection automatically sums the loads on each individual cell. Using this method of measurement, the maximum load will be the sum of the loads on the individual cells and the sensitivity will be the average value of these cells. It is important that the user ensures that no cell is stessed beyond its maximum rating under any load condition.
Kg
1
0.102
0.454
N
9.807 1
4.448
Lb
2.205
0.225 1
* The screen is isolated from the transducer body. It is recommended that the ground is connected at the instrument end.
6x0.25 Screened cable
VPT02A10-6PT2
MALE CONNECTOR
SIGNAL +
SIGNAL ­EXCITATION +
EXCITATION -
CALIBRATION SHUNT
CONNECTOR
OUTPUT
CABLE
OUTPUT
Red Black White
Green
Blue-Orange
Red Yellow or Black
White
Green
Yellow-Green
Red Yellow or Black
White Green
Yellow-Green
Yellow-Green
Red Yellow or Black
White
Green
SHUNT BOX