MINIATURE FORCE TRANSDUCER FOR
COMPRESSION APPLICATIONS
MECHANICAL DIMENSIONS
Main features
• Range of measurement: from 5 to 20 kN
• Accuracy class: 1%
• All stainless steel construction
• Corrosion resistant
• Grade of protection: IP65 (DIN 40050)
• Small size
The AM force transducers series have been designed to measure static and dynamic compression forces.
They are particularly suitable for monitoring pounding operations in compression which require a rugged transducer,
insensitive to high resonance frequencies caused by nonhomogeneous leads in dynamic sequences.
The accuracy and the stability are not affected by continuous
cycling under harsh conditions even with dynamic loads.
The small size of the AM force transducers makes them ideal
for retrofitting in existing equipment.
Dimensions mm. (± 0,1)
TECHNICAL DATA
1%
5...20 kN
2mV/V
<± 5% FSO
< ± 1% FSO
< ± 0,2% FSO
< ± 1% FSO
< ± 0,02% FSO°C
< ± 0,04% FSO°C
-
350 Ohm
> 10 GOhm
10 V
15 V
-20...+50°C
-20...+60°C
-30...+80°C
130% Ln
100% Ln
150% Ln
> 300% Ln
40% Ln
< 0,2 mm
IP65
4x0,15 / 2 m.
Stainless steel
Accuracy
Nominal full scale load (Ln)
Nominal output at FSO
Output tolerance at Ln
Combined errors: Non linearity
Histeresis, Repeatibility
Creep (after 30 min. at Ln)
Zero load out of balance signal
Thermal drift in Sensitivity
compensated Zero
range Calibration
Nominal bridge resistance
Isolation resistance
Nominal supply voltage
Maximum supply voltage
Compensated temperature range
Maximum temperature range
Storage temperature range
Permitted static load
Permitted dynamic load
Maximum applicable load
Rupture load
Maximum static lateral load
Maximum elastic deformation at Ln
Grade of protection (DIN40050)
Electr. connections screened cable
Elastic element material
LOAD
INTRODUCTION
DIRECTION
BALL R 40
SCREENED CABLE
DTS_AM_0709_ENG
GEFRAN spa reserves the right to make any kind of design or functional modification at any moment without prior notice.
ELECTRICAL CONNECTIONS
CONVERSION TABLE
ORDER CODE
Ex.: AM - KN5U
AM force transducer with range of measurement
0 - 5 kN.
If request, it is possible to supply models with non-standard
mechanical and/or electrical
features.
Force transducer AM
0 - 20 KN2D
MEASUREMENT RANGE (kN)
0 - 5
0 - 10
KN5U
KN1D
Cells connected in parallel
In systems that use several cells, the parallel
connection automatically sums the loads on each
individual cell.
Using this method of measurement, the maximum load
will be the sum of the loads on the individual cells and
the sensitivity will be the average value of these cells.
It is important that the user ensures that no cell is
stessed beyond its maximum rating under any load
condition.
Kg
1
0.102
0.454
N
9.807
1
4.448
Lb
2.205
0.225
1
OPTIONAL ACCESSORIES
* The screen is isolated from the transducer body.
It is recommended that the ground is connected at the
instrument end.
4x0.25
Screened cable
SIGNAL
SIGNAL
EXCITATION
EXCITATION
SHIELD
CABLE EXIT
Red
Yellow or Black
White
Green
Yellow-Green
Shield
White
Green
Red
Yellow
Red
Yellow or Black
White
Green
Yellow-Green
Red
Yellow or Black
White
Green
Yellow-Green
Yellow-Green
Red
Yellow or Black
White
Green
SHUNT BOX