Gefran 556 Data Sheet

556
QUARTZ TIMER / COUNTER / FREQUENCY METER
Main applications
Timer
Double timer
Cycle timer
Up/down counter
Cycle counter
Frequency meter
Main features
Input from mechanical contact, 2/3-wires proximity switch or AC voltage
Timer, counter, frequency meter configurable
Six time scales, 1msec resolution
Five counter prescalers
Quartz timer
Double display
Count back-up on EEprom
at power off
GENERAL
The model 556 is configurable for many different functions and is designed for reliability in industrial environments. The double display and minimum size make it the ideal choice for every require­ment for a timer, counter or frequency meter. The display can be expressed in the engi­neering units of the count effected using one of the five prescaler ranges. As a timer, it has six scale ranges from hundredths of a second to hours and minutes.
TECHNICAL DATA I
NPUTS
Isolated 1500V (with reference to logic output, for Vac power supply only). The unit has three inputs enabling the fol­lowing functions: Counter input, Timer / Counter reset, Up / Down or Start / Stop, Hold. Maximum frequency with 50% duty cycle:
- type 2 inputs: fmax = 100Hz
- type 1 inputs: fmax = 1KHz
- type 0 inputs: fmax = 5KHz Types of input: Mechanical contact: from a voltage free in open/closed configuration
Proximity switch: 2/3-wires NPN
Logic:
OFF 1Vdc, 3mA; 10Vdc < ON < 50Vdc
OUTPUTS
Relay
With rating 5A/250Vac at cosϕ = 1 (3,5A at cos
ϕ = 0,4)
Spark suppression on the NO contact.
POWER SUPPLY
110/220Vac ±10% 120/240Vac ±10% 24/48Vac ±10% 24Vdc ±10% 50/60Hz; 5VAmax.
TRANSMITTER SUPPLY
12Vdc, 30mA
AMBIENT CONDITION
Working temperature range: 0...50°C Storage temperature range: -20...70°C Humidity: 20...85%Ur non condensing
FUNCTIONALITY Timer
The timer can count up or count down according to the software setting. When the unit is used as a timer, the inputs have the following functions: IN1: Start/Stop input
IN2: Reset input IN3: Hold or Up/Down input The action of the output following an intervention is configurable.
Counter
The counter may also be configured to Count Up or Count Down according the software setting. The following Clock prescaler factors may be entered (:2, :10, :100, x2). The displayed / entered value can be expressed in engineering units of whatever is being measured. The conversion from a number to engineering units is obtained by entering suitable constants for the entries MOL and DIV which will be used respectively to multiply and divide the number of pulses counted. When the unit is used as a counter, the inputs have the following functions: IN1: Clock input (fmax. 5KHz) IN2: Reset input IN3: Hold or Up/Down input The action of the output is configurable.
Frequency meter
Used as a frequency meter, the input functions are: IN1: Clock input IN2: Reset of the Peak or Valley functions IN3: Hold input.
U6 Function Timer monostable timer with resetU5 Function Timer with Memory of Output 2
U4 Function Timer with Memory of Output 1U3 Function Cycle timer with timed reset
U2 Function Monostable cycle timer with reset
U1 Function Single (non-cycle) timer
with reset
(Standard)
Used as a frequency meter, the value can be displayed in engineering units using the factors MOL and DIV.
DESCRIPTION OF THE OUTPUT FUNCTIONS
The following are examples of the different possible output functions: configured as a timer with countdown and input IN3 with HOLD (a) or UP/DOWN (b) functions. In all other cases (counter or frequency meter) the function of the output is unchanged. Used as a Timer or a Counter, the maximum intervention time is 1msec., non-repetitive.
WEIGHT
240g
A - Main display, green digits h. 10mm B - Secondary display, green digits h. 7mm C - Function key D - Lower key E - Raise key F - Input/Output indication,
green LED OUT, red LED I1 and LED I2
IP54 faceplate protection
FACEPLATE DESCRIPTION
Timer
IN1
IN2
Relay
IN3
Timer
Relay
Timer 1
IN1 IN2
Relay
IN3
Relay
Timer 2
Timer 1 Timer 2
(b)
(a)
(b)
(a)
(b)
(a)
(b)
(a)
(b)
(a)
(b)
(a)
Timer 1
IN1 IN2
Relay
IN3
Relay
Timer 2
Timer 1 Timer 2
Timer 1
IN1 IN2
Relay
IN3
Relay
Timer 2
Timer
Timer 2
Timer
IN1 IN2
Relay
IN3
Timer Relay
Timer
IN1 IN2
Relay
IN3
Timer Relay
Time Time
Time
TimeTime
Time
E
F
A B
DC