Gefran 4T 72 Data Sheet

Max. non-linearity error See t.P parameter at page 3
For correct and safe installation, follow the instructions and observe the warnings contained in this manual.
Faceplate protection IP65 Working / Storage temperatures 0...50°C / -20...70°C Relative humidity 20 to 85%, non-condensing Installation Panel mounting Weight 90g for the complete version
Resolution (function of settable sample time)
120msec, >13bit - 8000 points 60msec, >13bit - 8000 points (only for linear inputs) 30msec, >12bit - 4000 points (only for linear inputs) 15msec, >11bit - 2000 points (only for linear inputs)
Thermocouples
J, K, R, S, T, B, E, N (IEC 584-1, CEI EN 60584-1, 60584-2)
L GOST, U, G, D, C Custom linearization available on request
Cold junction error 0,1° / °C RTD type (scale configurable within indicated
range, with or without decimal point) Max. RTD line resistance
DIN 43760 (PT100), JPT100 20
PTC type / NTC type 990, 25°C / 1K, 25°C
°C / °F selection Faceplate configurable
Linear scale ranges
-1999 to 9999 (with 4 digit display)
-999 to 999 (with 3 digit display)
-99 to 99 (with 2 digit display) Configurable decimal point position, possible 32 segment linearization
(option) Power supply for 2­wire transmitter
18V ±10%, 30 mA
1.2 V DC for potentiometer > 100 (version P77)
Power supply (switching)
11...27 V DC, 18...27VAC ±10%, 50/60Hz, 3VA (not isolated)
Display
2, 3, 4 digits, red, height 14 mm
Keys 3 mechanical keys (Raise, Lower, F) Accuracy
0.2% f.s. at 25°C ambient temperature, ts=120msec
Main input
TC, RTD, PTC, NTC 60 mV, 1 V, 5 V, 10 V, Ri 500K 20 mA, Ri = 50 adjustable digital filter
76
36
54
8
30
69,5
43
83
72
1 • INSTALLATION
Dimensions and cut-out: Panel mounting
Panel mounting:
Fix the device with the bracket provided before making any electrical connections. To mount two or more devices side by side, use the cut-out dimensions shown above.
CE MARKING: EMC (electromagnetic compatibility) conformity to EEC Directive 89/336/CEE with reference to the generic Standard EN61000-6-2 (immunity in industrial environments) and EN50081-1 (emission in residential environments). BT (low voltage) conformity to Directive 73/23/CEE as modified by Directive 93/68. MAINTENANCE: Repairs must be done out only by trained and specialized personnel. Cut power to the device before accessing internal parts. Do not clean the case with hydrocarbon-based solvents (Petrol, Trichlorethylene, etc.). Use of these solvents can reduce the mechanical reliability of the device. Use a cloth dampened in ethyl alcohol or water to clean the external plastic case. SERVICE: GEFRAN has a service department. The warranty excludes defects caused by any use not conforming to these instructions.
2 TECHNICAL SPECIFICATIONS
FUNCTION CABLE LENGTH USED TC input probe 0,8 mm2compensated 5 mt PT100 input probe 1 mm
2
3 mt
Power supply cable 1 mm
2
1 mt
EMC conformity has been tested with the following connections
!
8
4T 72
UNIVERSAL TEMPERATURE INDICATOR
SOFTWARE VERSION 1.0x / 2.0x code 81606A / edition 0.5 - 05/04
USERS MANUAL
9
Available thermocouples:
J, K, R, S, T, B, E, N,
L, U, G, D, C
- Respect polarities
- For extensions, use compensated cable appropriate for thermocouple.
Use wires of adequate thickness (min. 1mm
2
)
PT100, JPT100,
PTC, NTC
dc current
linear input
20mA, Ri = 50
(signal must be isolated
from power supply)
dc voltage linear input
60mV, 1V, 5V, 10V,
Ri 500K
(signal must be isolated
from power supply)
Raise and Lower keys:
These keys are used for any operation that requires a numerical parameter to be raised or lowered. •• The speed of change is proportional to the time the key is pressed. •• The operation is not cyclic: once the maximum (minimum) limit is reached, there will be no further increase (decrease) of the value, even if the key remains pressed. The keys can be configured to perform reset, hold, display of the peak value, etc. as determined by the t.U. and t.d. parameters on the In menu.
3 DESCRIPTION OF FRONT PANEL
Function key:
Gives access to different configuration stages •• Confirms
any parameter changes
Standard:
11...27Vdc ±10%
18...27Vac ±10%
50/60Hz, 3VA max.
not isolated
Linear (V)
Pt100 / PTC / NTC
3
1
2
2
1
+
-
Linear (I)
4
1
2
-
+
Power supply
11
12
~
~
+
-
Thermocouples
2
1
4
2
3
1
-
+
-
Ri = 50
4...20mA
Linear input with 2-wire transmitter
PWR
12411321
!
Label with engineering unit
4 CONNECTIONS
3-wire Pt100
2-wire PTC / NTC / Pt100
+
PV display: Indication of process variable Indication of HI or Lo out of range •• Indication of open circuit (br) or short circuit (Er) •• Display of configuration and calibration messages
5108976
T
T
Linear input for potentiometer
4
2
3
1
R >100
+ 1,2V
-
Device structure: identification of boards
S3
S4
CPU board
PROBE POWER board
RTD, PTC, NTC
input
ON
OFF
Transmitter and
potentiometer power supply
OFF
ON
S3
S4
S9
S8
S5
S1
S4
S6
S3
S7
Voltage
1V
24V (18V)
Jumpers
S4 - S6B - S7A
S6B - S7A
Probe power supply
Inputs
5 PROGRAMMING and CONFIGURATION
I F
P.V.
Process variable
Password
P A
PA = 99
P r
U.C.
Custom linearization
User calibration
YES
NO
LEVEL 1 DISPLAY
L n
Protection code
Information display
I n
Input settings
F
Pressed for approx. 2 sec.
Keep the F key
pressed to browse
the menus.
Release the F key
to enter the
displayed menu.
Press the F key to
access the
parameters.
Keep the F key
pressed to exit any
menu at any time.