Gefran 4A 48, 4A 96 Data Sheet

Main applications
Extrusion lines
Electrical panels
Test benches
Food processing equipment
4A 48 / 4A 96
AC CURRENT / VOLTAGE CONFIGURABLE INDICATOR
Main features
Protected by a personal code
Configurable by serial link
Labels to customize measured
physical unit
GENERAL
Microprocessor based indicator in both 48x48 (1/16 DIN) and 96x48 (1/8 DIN) formats manufactured with SMT. The instruments have a lexan mem­brane faceplate (guaranteed to IP65) which has 3 keys, a 3-digit display for the 48x48 format or a 3 / 4 digit display for the 96x48 format. The input signal section provides for the visualisation of the sinusoidal effec­tive value corresponding to following signals:
• AC voltage: 0 to 2, 0 to 20, 0 to 200 and 0 to 500Vac
• AC current: 0 to 20, 0 to 50, 0 to 200mAac 0 to 1, 0 to 5Aac
The selection is made using the face­plate keys and correct input terminals. No external shunt or adapter is requi­red. The programming of the instrument is made easy by grouping the parameters in function blocks and by a simplified data entry menu. The configuration can be simplified even further using the PC programming
kit made up of a connection cable and a menu guide program that runs under Windows (see data sheet code WIN­STRUM). A configurable personal software pro­tection code (password protection) can be used to restrict the levels of editing and displaying the configuration parameters.
TECHNICAL DATA
Inputs
Accuracy: 0,2% f.s. ±1 digit for 2Vac, 20Vac, 20mAac, 50mAac, 1Aac inputs 0,5% f.s. ±1 digit for 200Vac, 500Vac, 200mAac, 5Aac inputs The measurement of the effective value considers the sinusoidal signal. Sampling time 120msec, resolution 8000 steps. Configurable decimal point position, scale -1999 to 9999 (4 digit display) or
-999 to 999 (3 digit display with sign, only for the 96 format) with over- and under-range indication. Voltage input for 2Vac, 20Vac, 200Vac,
500Vac with Ri > 1MΩ.
Current input for 20mAac, 50mAac,
200mAac with Ri = 1,6Ω.
Current input for 1Aac, 5Aac with
Ri = 16mΩ.
power supply
4A 48
Standard:100 to 240Vac ± 10% max 5,5VA optional: 20 to 27Vac/dc ± 10% max 5,5VA
4A 96
Standard:100 to 240Vac/dc ± 10% max 5VA optional: 11...27Vac/dc ± 10% max 3VA
50/60Hz, protected by an internal fuse (not replaceable by the operator).
AmbIent condItIons
Working temperature range: 0 to 50°C Storage temperature range: -20 to 70°C Humidity: 20 to 85%Ur non-condensing
weIght
150g. (48 format), 280g. (96 format) in the complete version
FACEPLATE DESCRIPTION
A - Indication of process variable [for 48 format digit height 10mm; for 96 format digit height 20mm (3 digit), 14mm (4 digit); red display]
B - Label for engineering units C - “Function” key D - “Raise” and “Lower” keys E - key not used
IP65 faceplate protection
A
B
E
D
A
B
C
D
C
108
48
DIMENSIONS and CUT-OUT
63
48
45
99
10
70
48
70
45
105
10
Dimensions: 48x48mm - 96x48mm (1/16DIN - 1/8DIN) depth 99mm - 105mm
96
44,5
92
115
70
CONNECTION DIAGRAM
IN 2Vac, 20Vac, 200Vac, 500Vac
IN 20mAac, 50mAac, 200mAac
PWR
SUPPLY
IN 20mAac, 50mAac, 200mAac
AMP INP
IN 2Vac, 20Vac, 200Vac, 500Vac
VOLT INP
IN 1Aac, 5Aac
COM
COM
IN 1Aac, 5Aac
VOLT INP
AMP INP
PWR SUPPLY
!
Apply user’s manual warnings for a correct installation
ORDER CODE
4A
0 0
448
NR. DIGITS
4 4
0 0
NR. DIGITS
3 + sign 3
4 4
4A
96
Please, contact GEFRAN sales people for the codes availability.
POWER SUPPLY
20 to 27Vac/dc0
100 to 240Vac1
POWER SUPPLY
11to 27Vac/dc0
100 to 240Vac/dc1
GEFRAN spa reserves the right to make any modification of the design or function, at any moment without prior notice
EMC (electromagnetic compatibility): conforms to directive 2014/30/EU with reference to standard EN61326-1
Safety LVD: conforms to directive 2014/35/EU with reference to standard EN 61010-1
Loading...