Gefran 4A 48, 4A 96 Data Sheet

Main applications
Extrusion lines
Electrical panels
Test benches
Food processing equipment
4A 48 / 4A 96
AC CURRENT / VOLTAGE CONFIGURABLE INDICATOR
Main features
Protected by a personal code
Configurable by serial link
Labels to customize measured
physical unit
GENERAL
Microprocessor based indicator in both 48x48 (1/16 DIN) and 96x48 (1/8 DIN) formats manufactured with SMT. The instruments have a lexan mem­brane faceplate (guaranteed to IP65) which has 3 keys, a 3-digit display for the 48x48 format or a 3 / 4 digit display for the 96x48 format. The input signal section provides for the visualisation of the sinusoidal effec­tive value corresponding to following signals:
• AC voltage: 0 to 2, 0 to 20, 0 to 200 and 0 to 500Vac
• AC current: 0 to 20, 0 to 50, 0 to 200mAac 0 to 1, 0 to 5Aac
The selection is made using the face­plate keys and correct input terminals. No external shunt or adapter is requi­red. The programming of the instrument is made easy by grouping the parameters in function blocks and by a simplified data entry menu. The configuration can be simplified even further using the PC programming
kit made up of a connection cable and a menu guide program that runs under Windows (see data sheet code WIN­STRUM). A configurable personal software pro­tection code (password protection) can be used to restrict the levels of editing and displaying the configuration parameters.
TECHNICAL DATA
Inputs
Accuracy: 0,2% f.s. ±1 digit for 2Vac, 20Vac, 20mAac, 50mAac, 1Aac inputs 0,5% f.s. ±1 digit for 200Vac, 500Vac, 200mAac, 5Aac inputs The measurement of the effective value considers the sinusoidal signal. Sampling time 120msec, resolution 8000 steps. Configurable decimal point position, scale -1999 to 9999 (4 digit display) or
-999 to 999 (3 digit display with sign, only for the 96 format) with over- and under-range indication. Voltage input for 2Vac, 20Vac, 200Vac,
500Vac with Ri > 1MΩ.
Current input for 20mAac, 50mAac,
200mAac with Ri = 1,6Ω.
Current input for 1Aac, 5Aac with
Ri = 16mΩ.
power supply
4A 48
Standard:100 to 240Vac ± 10% max 5,5VA optional: 20 to 27Vac/dc ± 10% max 5,5VA
4A 96
Standard:100 to 240Vac/dc ± 10% max 5VA optional: 11...27Vac/dc ± 10% max 3VA
50/60Hz, protected by an internal fuse (not replaceable by the operator).
AmbIent condItIons
Working temperature range: 0 to 50°C Storage temperature range: -20 to 70°C Humidity: 20 to 85%Ur non-condensing
weIght
150g. (48 format), 280g. (96 format) in the complete version
FACEPLATE DESCRIPTION
A - Indication of process variable [for 48 format digit height 10mm; for 96 format digit height 20mm (3 digit), 14mm (4 digit); red display]
B - Label for engineering units C - “Function” key D - “Raise” and “Lower” keys E - key not used