Gefen USB100 User Manual

USB•100
USER MANUAL
www.gefen.com
Gefen Inc. wa
m
m
p
c
equipment it to be free fro material and
If equi because of su and Gefen In within two (2)
ASKING FOR ASSISTANCE
Technical Support:
Telephone (818) 884-6294 (800) 545-6900
Fax (818) 884-3108
Technical Support Hours:
8:00am to 5:00pm Monday thru Friday
Write To:
Gefen, Inc. C/O Customer Service 6265 Variel Avenue Woodland Hills, CA 91367-9897
rrants the
anufactures defects in orkmanship.
ment fails ch defects . is notifi ed
year from
Notice
Gefen Inc. reserves the right to make changes in the hard ware, packaging and any
accompanying doc u men ta tion without prior written notice.
USB•100 is a trademark of Gefen Inc.
ExtremeUSB is a trademark of Icron Inc.
Macintosh is a trademark of Apple
Computer Inc.
© 2007 Gefen Inc., All Rights Reserved
TABLE OF CONTENTS
1
Introduction
2
Operation Notes
3
USB Series Installation
4
USB•100 Panel Layout
5
USB•100 Function Description
6
Wiring Diagram
7
Link Cable Diagram
8
Check List
9
Troubleshooting Hints
10
Warranty
INTRODUCTION
Thank you for purchasing the ex•tend•it USB•100 Series. The new USB•100 incorporates ExtremeUSB™ techology, which allows users the benefi ts of USB technology beyond the desktop. Extending your USB peripherals (i.e. computer keyboard, mouse or trackball) up to 330 feet away from the location of your Macintosh or PC computer are done easily with the USB•100.
The USB•100 system consists of two units. The USB•100S sender resides next to the host computer, and the USB•100R receiver is linked to the sender via Category-5 (CAT-5) cable and resides at the desired location away from the computer.
The USB•100 signal is sent between the sender and receiver controls USB peripherals by buff ering the USB signal through send and receive line driv ers. The signal is extended by using standard Category 5 (CAT-5) cabling.
You can connect additional USB•100 systems to the same computer, allowing you to access the computer from multiple locations up to 330 feet apart.
1
OPERATION NOTES
READ THESE NOTES BEFORE INSTALLING OR
OPERATING THE USB•100 SYSTEM.
* The USB•100 send and receive were designed to operate on USB enabled computers. DO NOT attempt to use this equip ment with any other type of computer.
* Use the computer's USB port when using a local keyboard that is not extended with the USB•100 sender unit.
* In order to operate properly, the USB•100 receiver unit must be connected, powered, and the CAT-5 cable must be installed between the send and receive units.
* Only dedicated Category 5 UTP type cable (CAT-5) is recommended for this application (pin to pin).
* The length of cable used to connect the USB•100S send unit to the USB•100R receiver unit MUST NOT EXCEED 330 feet.
2
USB•100 SERIES INSTALLATION
1. Place the USB•100R unit close to the USB devices at the re mote end.
2. Connect the USB devices to the USB•100R unit.
3. Connect the power adapter to a suitable DC source wall outlet.
4. Connect the power adapter to the USB•100R unit using the supplied cable.
5. Place the USB•100S unit close to the host computer.
6. Connect the USB•100S unit to the USB•100R unit using the desired length of CAT5 cable
7. Connect the USB•100S unit to the host computer using the USB cable supplied with the unit. This connection should be made last.
3
USB•100 PANELS LAYOUT
USB•100S
USB In
1 2 3 4 5 6
Link
Power
USB•100R
Link
Power
10987
USB•100R
USB OUT
11
12
4
USB•100 FUNCTION DESCRIPTION
1
2
3
4
5
6
7
8
9
USB LED - Indicates if a USB connection is made properly USB In - USB cable (A-B) cable from computer to sender Link LED - Indicates if a link between the USB•100S send and the USB•100R
Receive units Link - CAT-5 Modular Jack which connects to the USB•100S send and the
USB•100R Receive units
Power LED - Indicates the unit is plugged in and powered up. DC IN - Power plug for 15VDC Wallmount power supply. Link LED - Indicates if a link between the USB•100S send and the USB•100R
Receive units Link - CAT-5 Modular Jack which connects to the USB•100S send and the
USB•100R receive units
Power LED - Indicates the unit is plugged in and powered up.
10
11
12
DC IN - Power plug for 15DAC Wallmount power supply. USB Led - Indicates if a USB device is plugged in USB input A - One USB A type connector
5
WIRING DIAGRAM
Up to 330 feet using CAT5 cable
USB•100R
USB•100S
6
LINK CABLE - WIRING DIAGRAM
8 1
1
2
3
Blue
White/Blue
White/Green
4
5
Brown
White/Brown
6
7
Green
White/Orange
8
Orange
1
2
RJ-45 Jack
3
4
5
7
6
7
8
8 1
CHECK LIST
1. On the USB•100S send unit, check that the power in di ca tor is GREEN.
2. On the USB•100S send unit, check that the link indicator is GREEN.
3. On the USB•100R receiver unit, check that the power in di ca tor is GREEN.
4. Once all LEDs are illuminated as suggested, the USB•100 is ready to accept a USB peripheral device at the USB port on the USB•100R receiver unit. Follow the installation in struc tions as if one were installing the device directly into a com put er's USB port.
5. On the host computer, check that a general purpose hub is visible in the Control Panel. Once con nect ed, a USB peripheral device causes its host computer to automatically enumerate it. This simply means that the computer must identify the new device, assign it an ID, and ensure that the required software drivers are available for loading when the device is to be used.
6. The USB•100 is not an end device. Consequently , it does not have a software component or driver to be loaded. Some peripheral devices that are to be at tached to the USB•100 will have a USB Driver diskette or CD-ROM which will need to be inserted after initial con­nection to a USB port on the USB•100 model.
8
TROUBLESHOOTING HINTS
Power Indicator is not lit.
-- Make certain the power supply unit is properly con nect ed to the USB•100R unit and to a proper local power sup ply outlet.
Link Indicators are Green.
-- Make certain that the host computer is operating and responding to commands. If re­quired, reset the com put er.
Problem Not Resolved
-- Disconnect power (DC Adaptor) plug from wall outlet that feeds power to the USB•100R unit.
-- Disconnect the USB•100S USB connection from the computer.
-- Reconnect power (DC Adaptor) from the USB•100R unit to the wall outlet.
-- Reconnect the USB•100S USB connection to the computer.
9
WARRANTY
Gefen Inc. warrants the equipment it manufactures to be free from defects in material and workmanship.
If equipment fails because of such defects and Gefen Inc. is notifi ed within two (2) year from the date of shipment, Gefen Inc. will, at its option repair or replace the equipment, provided that the equipment has not been subjected to mechanical, electrical, or other abuse or modifi cations.
Equipment that fails under conditions other than those covered will be repaired at the current price of parts and labor in effect at the time of repair. Such repairs are warranted for ninety (90) days from the day of reshipment to the Buyer.
This warranty is in lieu of all other warranties expressed or implied, including without limitation, any implied warranty or merchantability or fi tness for any particular purpose, all of which are expressly disclaimed.
1. Proof of sale may be required in order to claim warranty.
2. Customers outside the US are responsible for shipping charges to and from Gefen.
3. Copper cables are limited to a 30 day warranty and cable must be free from any scratches, markings, and neatly coiled.
The information in this manual has been carefully checked and is believed to be accurate. However, Gefen Inc. assumes no responsibility for any inaccuracies that may be contained in this manual. In no event will Gefen Inc., be liable for direct, indirect, special, incidental, or consequential damages resulting from any defect or omission in this manual, even if advised of the possibility of such damages. The technical information contained herein regarding EXT•USB-100 features and specifi cations is subject to change without notice.
All Rights Reserved © Copyright 2007 Gefen, Inc.
10
*MA-usb-100*
6265 Variel Avenue Woodland Hills, CA 91367
1-800-545-6900 818-884-6294 fax: 818-884-3108
www.gefen.com gsinfo@gefen.com
Loading...