All trademarks are the property of their respective companies
Rev X1
CONTENTS
1 Introduction
2 Operation Notes
3 Features
4 Sender Panel Layout
5 Sender Panel Descriptions
6 Receiver Panel Layout
7 Receiver Panel Descriptions
8 Connecting And Operating The USB 2.0 LR Extender
9 Troubleshooting
10 Network Cable Wiring Diagram
11 Wiring Diagram
12 Specifi cations
13 Warranty
INTRODUCTION
Congratulations on your purchase of the USB 2.0 LR Extender. Your complete
satisfaction is very important to us.
Gefen
Gefen delivers innovative, progressive computer and electronics add-on solutions
that harness integration, extension, distribution and conversion technologies.
Gefen’s reliable, plug-and-play products supplement cross-platform computer
systems, professional audio/video environments and HDTV systems of all sizes
with hard-working solutions that are easy to implement and simple to operate.
The Gefen USB 2.0 LR Extender
Gefen’s USB 2.0 LR extends high-speed USB devices simply and reliably.
The compact USB 2.0 LR Sender/Receiver units install in minutes and fully
support all USB versions (V1.1 and V2.0), at speeds of up to 480 mbps
-- essential for high-performance applications such as digital imaging and
interactive gaming.
The two-port USB 2.0 LR hub is ideal for remotely accessing laser printers,
scanners, web cameras, external hard drives, CD/DVD burners, and fl ash
drives. Additional applications include security, industrial control, digital signage,
scientifi c data acquisition and much more due to the universal implementation of
USB standards.
How It Works
Gefen’s USB 2.0 LR supports all major operating systems -- Windows, MacOS
and Linux. No software drivers are required.
When using in-wall building wiring, stranded patch cables may be used to
connect the Sender and Receiver to CAT5 wall plates. The combined length of all
patch cables must not exceed 33 feet (10m) and must be included as part of the
total extension.
A powered USB hub may be connected to the USB 2.0 Extender LR Receiver
to allow more USB devices to be extended. A maximum of 14 USB devices
(including hubs) may be connected to the USB 2.0 LR Receiver.
1
OPERATION NOTES
READ THESE NOTES BEFORE INSTALLING OR
OPERATING THE USB 2.0 LR EXTENDER
• Use industry standard CA T-5, CAT-5e or CAT-6. Gefen recommends using solid
core cabling for maximum performance.
• The USB 2.0 LR Extender is USB 2.0/1.1 compliant
• The USB 2.0 LR Extender can extend USB a maximum of 330 ft (100m)
• Use only the AC adapter supplied with the USB 2.0 LR Extender. Use of
substitute adapters may cause permanent damage to the system and will
void the warranty.
2
FEATURES
Features
• Operate USB 2.0 peripherals up to 330ft (100m) from a computer
• Supports low and high-speed USB
• Uses industry-standard CAT5, CAT5e, or CAT6 cable
• Supports all major operating systems -- Windows, MacOS and Linux.
• True plug-and-play, 100% hardware solution with no drivers required
• Operates at full 480 Mbps speed when running in USB 2.0 mode
• Receiver supports up to 2 USB powered connections at 500 mA each
• Specifi cations:
Package Includes
(1) Gefen USB 2.0 Extender over CAT5 LR Sender
(1) Gefen USB 2.0 Extender over CAT5 LR Receiver
(1) 5V DC Power Supply
(1) 6 ft. USB Cable
(1) User’s Manual
3
Front Panel
SENDER PANEL LAYOUT
Front Panel
1
23
Back Panel
4567
4
SENDER PANEL DESCRIPTIONS
1 Host Connection LED Indicator
This LED will become active once a valid connection is made by the host source
and the USB 2.0 LR Extender.
2 Power LED Indicator
This LED will become active once a valid connection is made between the
included 5V DC power supply and an open wall power socket.
3 USB “B” Input
Connect the USB source to this input.
4 Link LED Indicator
This LED will become active once a valid connection is between the sender and
receiver units.
5 CAT -5 Connection Port
Connect a CA T-5, CAT-5e or CAT-6 cable between this port and the CAT-5
connection port on the receiving unit.
6 Activity LED Indicator
This LED will be active when traffi c is passing between the sending and
receiving units.
7 5V DC Locking Power Receptacle
Connect the included locking 5V DC power supply between this port and an
open wall power socket.
5
Front Pane
l
RECEIVER PANEL LAYOUT
Front Panel
1
234
Back Panel
5678
6
RECEIVER PANEL DESCRIPTIONS
1 Host Connection LED Indicator
This LED will become active once a valid connection is made by the host source
and the USB 2.0 LR Extender.
2 Power LED Indicator
This LED will become active once a valid connection is made between the
included 5V DC power supply and an open wall power socket.
3 USB “A” Input 1
Connect the USB device to this input.
4 USB “A” Input 2
Connect the USB device to this input.
5 Link LED Indicator
This LED will become active once a valid connection is between the sender and
receiver units.
6 CAT -5 Connection Port
Connect a CA T-5, CAT-5e or CAT-6 cable between this port and the CAT-5
connection port on the sending unit.
7 Activity LED Indicator
This LED will be active when traffi c is passing between the sending and
receiving units.
8 5V DC Locking Power Receptacle
Connect the included locking 5V DC power supply between this port and an
open wall power socket.
7
CONNECTING AND OPERATING THE USB 2.0 LR EXTENDER
How to Connect the USB 2.0 LR Extender
1. Connect the USB source to the USB 2.0 LR Extender sender unit using the
supplied USB A to B cable.
2. Connect up to two USB peripherals to the USB 2.0 LR Extender receiver
using user supplied USB cables.
NOTE: Powered USB hubs may be connected to these ports up to a maximum
connection of 14 USB peripherals (including hubs).
3. Connect the USB 2.0 LR Extender sender and receiver units together with a
user supplied CAT-5, CAT-5e or CAT-6 cable.
NOTE: If fi eld terminating CAT-5 cables, please adhere to the TIA/EIA-568-B
specifi cation. Please see the NETWORK CABLE WIRING DIAGRAM on page 10
for more details.
4. Plug the included 5V DC power supplis into the USB 2.0 LR Extender sender
and receiver units.
Checking the Installation
On the sending and receiving units, check that the Power, Host and Link LEDs
are on and that the Activity LED is blinking. If the Link LED and Activity LED are
permanently off then the cabling between the sending and receiving units are not
installed properly or is defective.
For Windows users (2000, XP, or Vista) open Device Manager to confi rm that the
USB 2.0 LR Extender has installed correctly . Expand the entry for Universal Serial
Bus controllers by clicking the + sign. If the USB 2.0 LR Extender has been installed
correctly you should fi nd it listed as a Generic USB Hub.
For Mac OS X users open the System Profi ler to confi rm that the USB 2.0 LR
Extender has installed correctly . In the left hand column under Hardware, select
“USB” and inspect the right hand panel. If the USB 2.0 LR Extender has been
installed correctly you should fi nd it listed as a Hub under the USB High-Speed Bus/
USB Bus.
8
TROUBLESHOOTING
Using the Led Indicators to Troubleshot Issues
Power LED
The power LED indicators should be active once the included 5V DC power supply
has been properly connected between the sending/receiving unit and an open wall
power socket. A non-active LED can indicate a power problem. Please check that the
power cable is properly connected and locked to the sender/receiver unit.
Host LED
The host LED indicators should be active once a valid USB source/output device
has been properly connected to the sending/receiving unit. On the sender, the LED
indicator will only be active once the source device is on. A non-active LED may
indicate that the source device is not on or properly connected. On the receiver, the
LED indicator will only be active when a USB devices is properly connected and is
recognized by the source. A non-active LED may indicate that a USB device is not
properly connected or recognized by the source. Please check all USB cables and
install the proper drivers for the connected USB device.
Link LED
The link LED indicators should be active once a valid connection has been made
between the sending and receiving units. A non-active LED may indicate a problem
with the CA T-5 cabling. Please check terminations, patch panels, and cables. Use
other CA T-5 cables and test the units without using any patch panels.
9
NETWORK CABLE WIRING DIAGRAM
Gefen has specifi cally engineered their products to work with the TIA/EIA-568-B
specifi cation. Please adhere to the table below when fi eld terminating cable for
use with Gefen products. Failure to do so may produce unexpected results and
reduced performance.
PinColor
1Orange / White
2Orange
3Green / White
4Blue
5Blue / White
6Green
7Brown / White
8Brown
CAT-5, CAT-5e, and CAT-6 cabling comes in stranded and solid core types.
Gefen recommends using solid core cabling. CAT-6 cable is also recommended
for best results.
Each cable run must be one continuous run from one end to the other. No splices
or use of punch down blocks.
12345678
10
WIRING DIAGRAM
11
SPECIFICATIONS
USB 2.0 Speed ....................................................................................... 480 Mbps
Link Connectors ............................................................................. RJ-45 Shielded
USB Connectors Transmitter: ........................................................ (1) USB type B
USB Connectors Receiver: ............................................................. (2) USB type A
Dimensions Transmitter: ................................................... 1.7” W x 1.0” H x 3.4” D
Dimensions Receiver: ...................................................... 4.3” W x 1.1” H x 2.7” D
USB .......................................... Two 500 mA DC powered USB ports at Receiver
Power Supply ................................................................................ External 5V DC
Operating Temperature ............................................................................... 0-70 C
Unit Weight ........................................................................... Transmitter: 0.16 lbs.
Unit Weight ............................................................................... Receiver: 0.44 lbs.
en warrants the equipment it manufactures to be free from defects in material
and workmanship.
If equipment fails because of such defects and Gefen is notifi ed within two (2)
ears from the date of shipment, Gefen will, at its option, repair or replace the
quipment, provided that the equipment has not been subjected to mechanical,
lectrical, or other abuse or modifi cations. Equipment that fails under conditions
other than those covered will be repaired at the current price of parts and labor in
ect at the time of repair. Such repairs are warranted for ninety (90) days from
the day of reshipment to the Buyer.
This warrant
without limitation, any implied warranty or merchantability or fi tness for any
articular purpose, all of which are expressly disclaimed.
1.Proo
2.Customers outside the US are responsible for shipping charges to and from
.Copper cables are limited to a 30 day warranty and cables must be in their
ori
The information in this manual has been carefully checked and is believed to
be accurate. However,
that may be contained in this manual. In no event will Gefen be liable for
direct, indirect, special, incidental, or consequential damages resulting from
any defect or omission in this manual, even if advised of the possibility of such
damages. The technical information contained herein regarding the features and
pecifi cations is subject to change without notice.
is in lieu of all other warranties expressed or implied, including
sale may be required in order to claim warranty.
en.
inal condition.
en assumes no responsibility for any inaccuracies
13
*ma-USB2.0-LR*
Rev X1
20600 Nordhoff St., Chatsworth CA 91311
1-800-545-6900 818-772-9100 fax: 818-772-9120
www.gefen.com support@gefen.com