Gefen DVI RS232, EXT-DVI-CAT5-ELR User Manual

Page 1
®
DVI RS232
Extender over CAT5
with Ethernet
EXT-DVI-CAT5-ELR
User Manual
www.gefen.com
Page 2
ASKING FOR ASSISTANCE
Rev A2
29.81
Technical Support: Telephone (818) 772-9100 (800) 545-6900
Fax (818) 772-9120
Technical Support Hours:
8:00 AM to 5:00 PM Monday thru Friday.
Write To:
Gefen LLC c/o Customer Service 20600 Nordhoff St Chatsworth, CA 91311
www.gefen.com support@gefen.com
Notice
Gefen LLC reserves the right to make changes in the hard ware, packaging and
any accompanying doc u men ta tion without prior written notice.
DVI RS232 Extender over CAT5 with Ethernet
is a trademark of Gefen LLC
© 2011 Gefen LLC, All Rights Reserved.
All trademarks are the property of their respective owners.
Page 3
CONTENTS
1 Introduction 2 Operation Notes 3 Features 4 Sender Unit Layout 5 Sender Unit Descriptions 6 Receiver Unit Layout 7 Receiver Unit Descriptions 8 Connecting and Operating the DVI RS232 Extender over CAT5 with Ethernet 9 DIP Switches 10 DIP Switch Confi guration 12 Network Cable Wiring Diagram 13 Mounting Plate Installation 14 Specifi cations 15 Warranty
Page 4
1
Congratulations on your purchase of the DVI RS232 Extender over CAT5 with Ethernet. Your complete satisfaction is very important to us.
Gefen
Gefen delivers innovative, progressive computer and electronics add-on solutions that harness integration, extension, distribution and conversion technologies. Gefen’s reliable, plug-and-play products supplement cross-platform computer systems, professional audio/video environments and HDTV systems of all sizes with hard-working solutions that are easy to install and simple to operate.
The Gefen DVI RS232 Extender over CAT5 with Ethernet
The DVI RS232 Extender over CAT-5 with Ethernet extends any DVI source to a monitor, touch screen display, or other digital signage application placed at a distance up to 330 feet (100 meters) using one CAT-5 cable. This product also extends Ethernet and RS-232 using the same CAT-5 cable extension, allowing access to control devices using RS-232.
How It Works
Place the Sender Unit next to the DVI input source. Use the included DVI cable to connect the source to the Sender Unit. Connect the Receiver Unit to the moni­tor or digital signage display with a DVI cable (not supplied). Use one CAT-5 cable, up to 330 feet (100 meters), to connect the Sender Unit to the Receiver Unit. Connect an RS-232 serial cable from the RS-232 port on the Sender Unit to the RS-232 control device. Connect the RS-232 port on the Receiver Unit to the RS-232 device. Connect the Ethernet ports on both the Sender Unit and the Receiver Unit to any computer source and extended Ethernet device.
INTRODUCTION
Page 5
2
OPERATION NOTES
PLEASE READ THESE NOTES BEFORE INSTALLING OR
OPERATING THE DVI RS232 EXTENDER OVER CAT5 WITH
ETHERNET
CAT-5 or CAT-6 cables should not exceed 330 feet (100 meters).
Shielded (STP) CAT-5 or CAT-6 is recommended. However, un-shielded (UTP) CAT-5 or CAT-6 is acceptable.
NOTE: The shielded cable has an advantage by providing immunity to Electromagnetic Interference (EMI), cell phones and A/C motors.
The DVI RS232 Extender over CAT5 with Ethernet features the ability to generate compatible EDID and Hot Plug signals when working with different brands of source devices and monitors.
This product does not support HDCP content with DVI.
Page 6
3
FEATURES
Features
Extends any DVI, RS-232, and Ethernet devices up to 330 feet
Supports resolutions up to 1080p, 2K, and 1920x1200
Excellent for digital signage applications
Maximum Ethernet throughput of 100 Mbps, Full Duplex mode.
Uses one CAT-5e cable for DDC and control signals.
All-digital signal transmission for zero signal loss.
Locking power connectors.
Metal enclosure improves RF shielding.
Package Includes
(1) Gefen DVI RS232 Extender over CAT5 with Ethernet Sender Unit (1) Gefen DVI RS232 Extender over CAT5 with Ethernet Receiver Unit (1) 6 ft. DVI Cable (M-M) (2) 5V DC Locking Power Supplies (1) User Manual
Page 7
4
SENDER UNIT LAYOUT
Back
Front
1
24
56
3
Page 8
5
SENDER UNIT DESCRIPTIONS
1 5V DC Locking Power Connector
Connect the included 5V DC locking power supply to this connector.
2 Power Indicator
This LED will turn bright red once the included 5V DC locking power supply has been properly connected to the unit and the locking power supply has been connected to an available electrical outlet.
3 Locking DVI Port
Connect a DVI source to this port.
4 RS-232 Port
Connect the RS-232 host device to this port.
5 Link Output Jack
Connects the Sender Unit to the Receiver Unit using a CA T-5 cable.
6 Ethernet Input Jack
Connects the Sender Unit to the network using an Ethernet cable.
Page 9
6
RECEIVER UNIT LAYOUT
Back
Front
1
23
56
4
Page 10
7
RECEIVER UNIT DESCRIPTIONS
1 RS-232 Port
Connect the RS-232 device to this port.
2 Locking DVI Port
Connect a DVI source device to this DVI port.
3 5V DC Locking Power Connector
Connect the included 5V DC locking power supply to this connector.
4 Power Indicator
This LED will turn bright red once the included 5V DC locking power supply has been properly connected to the unit and the locking power supply has been connected to an available electrical outlet.
5 Ethernet Output Jack
Connects the Receiver Unit to the network device.
6 Link Input Jack
Connects the Sender Unit to the Receiver Unit using CA T-5 cabling.
Page 11
8
CONNECTING AND OPERATING
THE DVI RS232 EXTENDER OVER CAT5 WITH ETHERNET
How to Connect the DVI RS232 Extender over CAT5 with Ethernet
1. Connect the DVI source to the Sender Unit using the provided DVI cable. Connect the DVI monitor to the Receiver Unit using a DVI cable.
2. Connect an Ethernet cable from the device/router to the Ethernet input port on the Sender Unit with a CAT-5e or CAT-6 cable.
3. Connect the Ethernet output port on the Receiver Unit to the remote device/ router with a CAT-5e or CAT-6 cable.
4. Connect a CAT-5e or CAT-6 cable between the Link port on the Sender Unit and the Link port on the Receiver Unit.
NOTE: If terminating network cables in the fi eld, please adhere to the TIA/ EIA568B specifi cation (please see page 12).
5. Connect the 5V DC locking power supplies to the Sender Unit and Receiver Unit. Do not overtighten the locking connectors. Plug the two (2) power supplies to an available electrical outlet.
6. Power on the DVI monitor and the DVI source.
Wiring Diagram for the DVI RS232 Extender over CAT5 with Ethernet
EXT-DVI-CAT5-ELR
CAT5 ETHERNET CABLE
CAT5 LINK CABLE
(Up to 330 ft)
Sender
DVI Source
Router
Receiver
Touchscreen Display
DVI CABLE
RS-232 CABLE
Rece
iv
Page 12
9
DIP SWITCHES
DIP Switch Location
On the bottom of the DVI RS232 Extender over CAT5 with Ethernet Receiver unit there are four (4) DIP switches.
The DIP switches allow advanced EDID management of the DVI RS232 Extender over CAT5 with Ethernet which may be necessary when using different brands of hardware. The DIP switches allow control over the EDID, HPD (Hot Plug Detect), and RS-232 modes.
Default settings for DIP switches
DIP Switch Position 1 OFF 2 OFF 3ON 4 OFF
Receiver Unit DIP Switches
Page 13
10
DIP SWITCH CONFIGURATION
DIP 1 - EDID Mode
ON - External EDID Mode
DDC and HPD are passed through. Both the connection status and the full video capabilities of the monitor. The HPD status will also be detected by the source device.
OFF (default) - Internal EDID Mode
Local EDID is used instead of the EDID from the display device. EDID features newer than HDMI 1.3 are removed when the display is read. This provides a general EDID which is compatible with more displays.
DIP 2* - Hot-Plug Detect
ON - HPD Pass-Through
HPD follows upstream HPD towards the source. The HPD signal will refl ect the connection status between the display device and the source device. If the source or monitor is temporarily disconnected then reconnected, there will be a delay of 20 - 30 seconds before the content is restored to the monitor.
OFF (default) - HPD Always High
The HPD signal remains high regardless of the downstream HPD state. If the source or monitor does not properly handle HPD (no picture after con­necting / reconnecting source or display), set this DIP switch to the OFF position.
Page 14
11
DIP SWITCH CONFIGURATION
DIP 3* - Supports DVI Connections
ON (default)
If a DVI connection is used, set DIP 3 to the ON position. DVI is supported by disabling HDCP pass-through.
OFF
If HDMI is connected, set DIP 3 in the OFF position.
*DIP switch is only functional when DIP switch 1 is set to OFF.
DIP 4 - RS-232 Mode
ON - Enable Field Upgrade Mode
• Allows the fi rmware to be upgraded on the Receiver Unit. In this mode, the RS-232 portion of the extender will not function.
OFF (default) - RS-232 Pass-through
Use when extending RS-232 between the Sender Unit and the Receiver Unit. DIP switch 4 must be set to the OFF position for normal operation of the DVI RS232 Extender over CAT5 with Ethernet.
Page 15
12
NETWORK CABLE WIRING DIAGRAM
12345678
Gefen recommends the TIA/EIA-568-B wiring option. Please adhere to the table below when fi eld terminating cable for use with Gefen products.
Pin Color
1 Orange / White 2 Orange 3 Green / White 4 Blue
5 Blue / White 6 Green 7 Brown / White 8 Brown
CAT-5, CAT-5e, and CAT-6 cabling comes in stranded and solid core types. Gefen recommends using solid core cabling. CAT-6 cable is also recommended.
It is recommended to use one continuous run from one end to the other. In some cases, connecting through a patch might not work.
Page 16
13
MOUNTING PLATE INSTALLATION
1
2
3
Remove the rubber feet covering the screws off the bottom of the unit.
Remove the screws.
Line up the mounting plates and screw it on to the unit.
Page 17
13
Maximum Pixel Clock .............................................................................. 225 MHz
Input Video Signal ................................................................................... 1.2 V p-p
Input DDC Signal .............................................................................. 5 V p-p (TTL)
Max. Video Resolution Supported ............................................1080p / 1920x1200
Max. Ethernet Data Transfer Rate........................................................... 100 Mbps
Ethernet Packet Transmission Mode ....................................................Full Duplex
DVI Connectors .......................................................................... Type-A 19-Pin (F)
Link Connector .............................................................................. RJ-45 Shielded
Power Indicator.........................................................................................LED (red)
Power Supply ............................................................................................. 5 V DC
Power Consumption .............................................................. 10 W per unit (max.)
Operating Temperature .............................................................................0 - 40 °C
Dimensions ................................................................... 3.4” L x 3.25” W x 1.25” H
Shipping Weight ............................................................................................ 3 lbs.
SPECIFICATIONS
Page 18
14
Page 19
Rev A2
29.81
20600 Nordhoff St., Chatsworth CA 91311
1-800-545-6900 818-772-9100 fax: 818-772-9120
www.gefen.com support@gefen.com
P
b
Loading...