Gebr. Schmidt D-57482 User Manual

Gebr. Schmidt GmbH
Industriegebiet-Ost, Alte Waldstraße
D-57482 Wenden - Hünsborn
Operating Manual
Radial fans
with direct drive
Information for the user:
Assembly Commissioning Maintenance
Page 1 Revision status 01/2021
Gebr. Schmidt GmbH
Industriegebiet-Ost, Alte Waldstraße
D-57482 Wenden - Hünsborn
1.) Introduction 3
2. ) Safety 4
2.1) Symbols 4
2.2) In the case of non-compliance with safety instructions, there is 5 a risk of injury!
3.) Design data / signage 6
3.1) The nameplate provides information on 6
3.2) Direction arrow 6
3.3) Motor data 6
4.) Assembly 7
4.1) Transport 7
4.2) Delivery 7
4.3) Storage 7
4.4) Place of installation 8
4.5) Installation 8
4.6) Ductwork 8
4.7) Electrical installation 9
5.) Commissioning the fan 10
6.) Fan start-up 11
7.) Maintenance 11
7.1) General information 12
7.2) Impellor and housing 12
7.3) Maintenance and control checklist 13
8.) Troubleshooting 14
9.) Commissioning protocol / checklist 16
10.) Ordering spares and the services of fitters 17
Page 2 Revision status 01/2021
Gebr. Schmidt GmbH
Industriegebiet-Ost, Alte Waldstraße
D-57482 Wenden - Hünsborn
1.) Introduction
To obtain perfect operation of fans, thorough execution of all work stages, from production to final assembly, is essential. Therefore, this guideline is to provide assistance for all operations which are under your responsibility. It is one of our policies that each fan leaving our works is submitted to strict examination and a test run to check for output and vibration.
To this documentation additional documents are appended which should also be noted. If you need more information about the fan than is included in this manual, please contact your supplier directly. This manual only applies to directly driven designs. Technical design of the fan is in accordance with DIN 24166 "Fans – Technical Delivery Conditions".
Page 3 Revision status 01/2021
Gebr. Schmidt GmbH
Industriegebiet-Ost, Alte Waldstraße
D-57482 Wenden - Hünsborn
2.) Safety
2.1) Symbols
General information
General danger signals
Explosion hazard
Risk of injury
Electrical voltage
Instruction manual
Page 4 Revision status 01/2021
Gebr. Schmidt GmbH
Industriegebiet-Ost, Alte Waldstraße
D-57482 Wenden - Hünsborn
2.2) In the event of non-compliance with safety regulations, there is a risk of injury!
For installation and commissioning, all safety and accident prevention
regulations as well as the EC machinery directive must be observed.
The fan may only be operated in a perfect condition.
The protective equipment for installation, maintenance and repair must comply with the safety regulations.
Do not bypass, disconnect or remove any protective equipment!
Any work on the fan may only be carried out during a standstill. Protect the
motor from unintentional start-up.
Any alterations of or modifications to the fan are not permitted.
The operator must also ensure that the fan is operated in accordance with
the electro-technical regulations.
The operator must ensure that the fan is connected only by a person with electrical knowledge.
Any electrical defects found must be immediately remedied. If there is imminent danger until such defect has been remedied, the fan must not be operated in a defective state.
In an explosive atmosphere, only fans fitted with appropriate technical
equipment may be operated. In this case, please consult Messrs. Schmidt GmbH.
Page 5 Revision status 01/2021
Gebr. Schmidt GmbH
Industriegebiet-Ost, Alte Waldstraße
D-57482 Wenden - Hünsborn
In priciple, the Gebr. Schmidt operating and maintenance instructions must
be observed before commissioning. This also applies to the installed components of the blower, such as the drive motor, compensators, fan bearings, etc. If these are not available, they must be requested from Gebr. Schmidt.
3.) Design data / signage
3.1.) The nameplate gives information on:
- Manufacturer
- Address
- Company logo
- Fan rating
3.2) Direction arrow
The fan is provided with a direction arrow indicating the correct direction of rotation.
3.3) Motor data
The motor data can be found on the manufacturer's nameplate. Nameplates may appear differently, depending on the manufacturer.
Page 6 Revision status 01/2021
Loading...
+ 11 hidden pages