GE ZXR859, ZXR8510, ZXR858 User Manual

Installation Instructions
If you have questions, call 800.GE.CARES or visit our website at: www.monogram.com
Recirculating Accessories
For Model ZV850, Island Vent Hood
M
o
n
o
g
r
a
m
®

Installation Preparation

BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT – Save these instructions
for local inspector’s use.
IMPORTANT – Observe all governing
codes and ordinances.
Note to Installer – Be sure to leave these
instructions with the Consumer.
Note to Consumer – Keep these instructions with
your Owner’s Manual for future reference.
Skill Level – Installation of this appliance requires basic mechanical and electrical skills.
Completion time – 1 to 3 hours.
• Proper installation is the responsibility of the installer.
• Product failure due to improper installation is not covered under the Warranty.
For Monogram local service in your area,
1.800.444.1845.
For Monogram service in Canada, call
1.888.880.3030.
For Monogram Parts and Accessories, call
1.800.626.2002.
CAUTION:
Due to the weight and size of this vent hood and to reduce the risk of personal injury or damage to the product, TWO PEOPLE ARE REQUIRED FOR
PROPER INSTALLATION.
WARNING: The improper connection of
the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative if you are in doubt whether the appliance is properly grounded.
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A. Use this unit only in the manner intended by the
manufacturer. If you have any questions, contact the manufacturer. B. Before servicing or cleaning unit, switch power off at the service panel and lock service panel to prevent power from being switched on accidentally. If the service panel cannot be locked, fasten a tag or prominent warning label to the panel.
For general ventilating use only. Do not use to exhaust hazardous or explosive materials or vapors.
Structural framing, installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
Local codes vary. Installation electrical connections and grounding must comply with applicable codes. In the absence of local codes, the vent should be installed in accordance with National Electrical Code ANSI/NFPA 70-1990 or latest edition.
CONTENTS
Installation Preparation
Required Accessories .................................................. 3
Product Dimensions ................................................... 3
Duct Cover Accessories .............................................. 4
Power Supply .............................................................. 4
Tools and Materials Required .................................... 4
Remove Packaging, Check Contents ......................... 5
Install Ceiling Support ............................................... 6

Installation Instructions

Step 1, Mount Template ........................................... 6
Step 2, Install Upper Support Frame ...................... 7
Step 3, Install Lower Support Frame ....................... 7
Step 4, Secure Wiring ............................................... 8
Step 5, Size and Install Ductwork ............................ 8
Step 6, Install Decorative Duct Covers .................... 9
Step 7, Install Hood ................................................ 10
Step 8, Connect Electrical ...................................... 10
Step 9, Slide Duct Covers Down,
Install Utility Bars ....................................... 11
Step 10, Install Filters ............................................... 11
Step 11, Finalize Installation .................................... 11
2
Installation Preparation

REQUIRED ACCESSORIES

This book provides step by step instructions to install the Monogram ZV850 ceiling mounted hood for recirculating operation.
• One of the following accessory kits is required for non­vented ceiling mounted installations of model ZV850.
Choose the correct kit according to ceiling heights:
ZXR858 – For 8 ft. ceiling height. ZXR859 – For 9 ft. ceiling height ZXR8510 – For 10 ft. ceiling height.

PRODUCT DIMENSIONS

The vent hood must be installed 24 min. and 30 max. above the cooking surface. 25-1/2 is recommended for best performance and to ensure that the duct cover meets the ceiling. The cooking surface should be at least 36 above the floor. Installation will be easier if the vent hood is installed before the cooktop and countertop is installed.
• Order the required accessory at the same time as the vent hood and have on site before installation.
• Each kit includes decorative duct covers, a support frame, air deflector and charcoal filters.
*Height
to Ceiling
8-1/4"
*25-1/2" Recommended
36" Reference
35-3/8"
27-1/2"
* 26-1/4” for 8 ft. Ceiling Using ZXR858 Accessory
38-1/8” for 9 ft. Ceiling Using ZXR859 Accessory
50-1/8” for 10 ft. Ceiling Using ZXR8510 Accessory
* The distance between the cooking surface and the bottom of the
hood must be at least 24” and up to 30”. The 25-1/2” recommended installation height, above the standard 36” countertop, will ensure duct cover fit to the ceiling.
3
Installation Preparation
USING DUCT COVER ACCESSORIES
A duct cover accessory is required for all ceiling heights. Use this chart to determine the correct Duct Cover Accessory for 8-ft. to 10-ft. ceilings that must be ordered with the hood.
ZV850SB Installation Heights
Actual
Ceiling
Height
7 11
8 0
8 1
8 2
8 3
8 4
8 5
8 6
8 7
8 8
8 9
8 10
8 11
9 0
9 1
9 2
9 3
9 4
9 5
9 6
9 7
9 8
9 9
9 10
9 11
10 0
*Based on 36 countertop height.
*Possible Hood
Installation Height
24-1/2
25-1/2
25-1/2 to 26-1/2
25-1/2 to 27-1/2
25-1/2 to 28-1/2
25-1/2 to 29-1/2
30 max.
30 max.
30 max.
30 max.
30 max.
30 max.
30 max.
30 max.
30 max.
30 max.
30 max.
30 max.
30 max.
30 max.
30 max.
30 max.
30 max.
30 max.
30 max.
30 max.
ZV850SB Duct Cover Dimensions
Recirculating
Installation
ZXR858C
ZXR859C
ZXR8510C
A
14-3/16
21-7/8
26
Recirculating
Accessory
B
15
22-1/2
27-15/16
ZXR858C
ACCESSORY
ACCESSORY ZXR859C
ACCESSORY ZXR8510C
9-7/16"
A
15-3/4"

POWER SUPPLY

IMPORTANT - (Please read carefully)
WARNING:
FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED.
Remove house fuse or open circuit breaker before beginning installation.
Do not use an extension cord or adapter plug with this appliance. Follow National electrical codes or prevailing local codes and ordinances.
Electrical supply
This vent hood must be supplied with 120V, 60Hz, and connected to an individual, properly grounded branch circuit, and protected by a 15 or 20 amp circuit breaker or time delay fuse.
• Wiring must be 2 wire with ground.
• If the electrical supply does not meet the above requirements, call a licensed electrician before proceeding.
• Route house wiring in the ceiling, as close to the installation location as possible. Allow an addi­tional 3 feet length from ceiling joists to reach the junction box on the hood.
• Connect the wiring to the house wiring in accor­dance with local codes.
Grounding instructions
The grounding conductor must be connected to a ground metal, permanent wiring system, or an equipment-grounding terminal or lead on the hood.
WARNING: The improper connection of
the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electri­cian or service representative if you are in doubt whether the appliance is properly grounded.

TOOLS AND MATERIALS REQUIRED

• Tape measure
• Knife
• Spirit level
• Wire cutter/stripper
• Wire nuts
• Electric drill and 5/32” bit
B
• Phillips and flat-blade screwdrivers
• Hammer
• Pliers
• Center punch
4
(NOT SUPPLIED)
• 10 mm Hex wrench/socket
• Safety glasses
• Duct tape
• Plumb
• Gloves to protect against sharp edges
• 120V 60Hz. 15 or 20 Amp, 2 wire with ground. Properly grounded branch circuit.
• Strain relief for junction cover
• 6” round duct, length to suit installation