ZVB36SH/BH/WH – GE Monogram 36" Telescopic Downdraft Vents
Dimensions and Specifications (in inches)
36
34
All 36” models are equipped with a separate raise/lower switch. The switch must be installed in a separate location outside of the vent and cooktop cutout.
Countertop Requirements
Countertops must have a deep flat surface to accommodate the cooktop and the vent. Countertops with a rolled edge and backsplash may not provide the flat surface area required.
Base Cabinet Requirements
The base cabinet must be deep enough to accommodate the minimum clearance to the front edge of the countertop, the cooktop burner box and the vent.
Downdraft Vent and Cooktop Cutout
Specification Created 10/03
130656
The installation of these downdraft vents with any Monogram cooktop requires careful consideration. For accurate planning, review the individual dimension drawings for the combined vent and Monogram cooktop installation.
Listed by Underwriters Laboratories
Separate Raise/Lower Switch
Before you begin you must:
1. Review countertop dimension illustrations
For answers to your Monogram,® GE Profile™ or
®
GE GEAppliances.com or call GE Answer Center
to be sure you will have enough flat countertop surface depth.
2. Check to be sure that the total countertop depth required (including minimum cutout to front edge depth) allows enough space for a backsplash.
3. Review the cabinet illustration. Check to be sure that the interior cabinet depth will house the cooktop burner box, the vent and the cutout clearance from the front.
4. When countertop and cabinet depth present a problem, review Creative Solutions.
5. Carefully review the installation instructions packed with product or available online at www.monogram.com.
With careful planning you can achieve a custom look with minimal adjustments.
®
service, 800.626.2000.
ZVB36SH/BH/WH – GE Monogram 36" Telescopic Downdraft Vents
R
Base Cabinet
Filler Panel
Base Sink
Filler Panel
Maintain Cutout Clearances
to Front Edge as Specified
Cover Panel
Base Sink
End Panel
Countertop Overhang per Cooktop
Clearances Must be Maintained
DOWNDRAFT
VENT
1-7/8"
Trim
Add a Bullnose Trim or Decorative Molding to Increase Countertop Depth and to Maintain Required Clearance From Front Edge
Creative Solutions
Against-the-wall installation
Move the base cabinet forward, 3" to 5". Filler panels or complimentary moldings can be added to the exposed cabinet sides.
Specification Created 10/03
130656
Island or peninsula installation
Use an extra-deep countertop. The countertop overhang at the front can be adjusted to meet setback to cutout requirements.
Decorative trim
When the cutout to front edge of the countertop requirement is more than 2", add a bullnose trim to the front edge of the countertop. The additional trim allows the cooktop to be moved forward, providing additional countertop depth and interior cabinet space.
Optional Accessories
JXRB67 Accessory for indoor remote location
of the blower/motor assembly. Use this kit when the blower and motor assembly will be located outside of the cabinet, such as below the cabinet floor. The assembly will fit between 16" floor joists.
JXBC67 Outdoor cover accessory for remote installation of the blower/motor assembly on an outside wall.
Ductwork
Prepare the ductwork to vent to the outdoors.
• Plan the shortest and straightest route for venting exhaust to the outdoors.
• The maximum permissible length for the duct run is 150 feet.
• Use metal ductwork only.
• The downdraft blower system is designed to use 3-1/4" x 10" duct. It can be transitioned to 6" round.
• Install a wall cap or roof cap with damper at the exterior opening. Order the wall cap and any transition needed in advance.