GE ZVB30SH, ZVB30BH, ZVB30WH User Manual

Page 1
R
2-1/4"
3-1/8"
10-1/2"
3-3/8"
3-3/4"
7-1/2"
6-1/4"
2"
8-1/2" Lift
7-1/8"
30"
28-1/2"
27"
ZVB30SH/BH/WH – GE Monogram 30" Telescopic Downdraft Vents
Dimensions and Specifications (in inches)
All 30” models are equipped with a separate raise/lower switch. The switch must be installed in a separate location outside of the vent and cooktop cutout.
Countertop Requirements
Countertops must have a deep flat surface to accommodate the cooktop and the vent. Countertops with a rolled edge and backsplash may not provide the flat surface area required.
Base Cabinet Requirements
The base cabinet must be deep enough to accommodate the minimum clearance to the front edge of the countertop, the cooktop burner box and the vent.
Downdraft Vent and Cooktop Cutout
Specification Created 10/03
130658
The installation of these downdraft vents with any Monogram cooktop requires careful consideration. For accurate planning, review the individual dimension drawings for the combined vent and Monogram cooktop installation.
Listed by Underwriters Laboratories
Separate Raise/Lower Switch
Before you begin you must:
1. Review countertop dimension illustrations
For answers to your Monogram,® GE Profile™ or
®
appliance questions, visit our website at
GE GEAppliances.com or call GE Answer Center
to be sure you will have enough flat countertop surface depth.
2. Check to be sure that the total countertop depth required (including minimum cutout to front edge depth) allows enough space for a backsplash.
3. Review the cabinet illustration. Check to be sure that the interior cabinet depth will house the cooktop burner box, the vent and the cutout clearance from the front.
4. When countertop and cabinet depth present a problem, review Creative Solutions.
5. Carefully review the installation instructions packed with product or available online at www.monogram.com.
With careful planning you can achieve a custom look with minimal adjustments.
®
service, 800.626.2000.
Page 2
ZVB30SH/BH/WH – GE Monogram 30" Telescopic Downdraft Vents
R
Base Cabinet
Filler Panel
Base Sink
Filler Panel
Maintain Cutout Clearances
to Front Edge as Specified
Cover Panel
Base Sink
End Panel
Countertop Overhang per Cooktop
Clearances Must be Maintained
DOWNDRAFT
VENT
1-7/8"
Trim
Add a Bullnose Trim or Decorative Molding to Increase Countertop Depth and to Maintain Required Clearance From Front Edge
Creative Solutions
Against-the-wall installation
Move the base cabinet forward, 3" to 5". Filler panels or complimentary moldings can be added to the exposed cabinet sides.
Specification Created 10/03
130658
Island or peninsula installation
Use an extra-deep countertop. The countertop overhang at the front can be adjusted to meet setback to cutout requirements.
Decorative trim
When the cutout to front edge of the countertop requirement is more than 2", add a bullnose trim to the front edge of the countertop. The additional trim allows the cooktop to be moved forward, providing additional countertop depth and interior cabinet space.
Optional Accessories
JXRB67 Accessory for indoor remote location
of the blower/motor assembly. Use this kit when the blower and motor assembly will be located outside of the cabinet, such as below the cabinet floor. The assembly will fit between 16" floor joists.
JXBC67 Outdoor cover accessory for remote installation of the blower/motor assembly on an outside wall.
Ductwork
Prepare the ductwork to vent to the outdoors.
• Plan the shortest and straightest route for venting exhaust to the outdoors.
• The maximum permissible length for the duct run is 150 feet.
• Use metal ductwork only.
• The downdraft blower system is designed to use 3-1/4" x 10" duct. It can be transitioned to 6" round.
• Install a wall cap or roof cap with damper at the exterior opening. Order the wall cap and any transition needed in advance.
Listed by Underwriters Laboratories
For answers to your Monogram,® GE Profile™ or
®
appliance questions, visit our website at
GE GEAppliances.com or call GE Answer Center service, 800.626.2000.
®
Page 3
ZVB30SH/BH/WH – GE Monogram 30" Telescopic Downdraft Vents
Discharge Down
(As Supplied)
Discharge Left
Discharge Right
34" for 36" Models
28-1/2" for 30" Models
29-1/2"
Electrical Outlet 12" Above Cabinet Floor
Do Not Locate Gas or Electrical
Connections Within Shaded Area
R
Venting Options
The downdraft vent is shipped with the discharge outlet pointing straight down and can be changed to a left- or right-side discharge. For even more flexibility, the entire blower and mounting plate can be adjusted 3-1/2" to the left or right sides.
Electrical and Gas Locations
Plan the placement of the electrical outlet and gas (if used) carefully. Gas or electrical outlets cannot be located on the back wall of the cabinet because they may interfere with the downdraft plenum.
• Install a standard electrical outlet within reach of the vent’s two-foot-long power cord. Locate the outlet inside the cabinet on the right side wall.
• If the vent is installed in combination with a Monogram® gas cooktop, it may operate from the same 120V standard duplex outlet.
• If the vent is installed in combination with a Monogram electric cooktop, the vent must operate from a separate 120V outlet.
Specification Created 10/03
130658
Listed by Underwriters Laboratories
For answers to your Monogram,® GE Profile™ or
®
appliance questions, visit our website at
GE GEAppliances.com or call GE Answer Center
®
service, 800.626.2000.
Page 4
ZVB30SH/BH/WH – GE Monogram 30" Telescopic Downdraft Vents
Features and Benefits
• 30" Telescopic downdraft system
• 500 CFM performance
• Remote-mounted control
• Variable-speed fan with slide control
• Raises to 8-1/2" over cooktop surface
• Retracts when not in use
• Removable grease filters
• 3-1/4" x 10" rectangular duct
• Optional remote blower capabilities
• Stainless steel vent body
• Minimum 6" round duct capabilities
• Model ZVB30SHSS – Stainless steel (shown)
Specification Created 10/03
130658
• Model ZVB30WHWW – White on white
• Model ZVB30BHBB – Black on black