ZVB30SH/BH/WH – GE Monogram 30" Telescopic Downdraft Vents
Specification Created 10/03
130658
Dimensions and Specifications (in inches)
For answers to your Monogram,® GE Profile™ or
GE
®
appliance questions, visit our website at
GEAppliances.com or call GE Answer Center
®
service, 800.626.2000.
Listed by
Underwriters
Laboratories
Counter top Requirements
Countertops must have a deep flat surface to
accommodate the cooktop and the vent.
Countertops with a rolled edge and backsplash
may not provide the flat surface area required.
Base Cabinet Requirements
The base cabinet must be deep enough to
accommodate the minimum clearance to the
front edge of the counter top, the cooktop
burner box and the vent.
Downdraf t Vent and Cooktop Cutout
The installation of these downdraft vents
with any Monogram cooktop requires careful
consideration. For accurate planning,
review the individual dimension drawings
for the combined vent and Monogram
cooktop installation.
Before you begin you must:
1. Review countertop dimension illustrations
to be sure you will have enough flat
countertop surface depth.
2. Check to be sure that the total countertop
depth required (including minimum cutout
to front edge depth) allows enough space
for a backsplash.
3. Review the cabinet illustration. Check to
be sure that the interior cabinet depth will
house the cooktop burner box, the vent and
the cutout clearance from the front.
4. When countertop and cabinet depth present
a problem, review Creative Solutions.
5. Carefully review the installation instructions
packed with product or available online at
www.monogram.com.
With careful planning you can achieve a
custom look with minimal adjustments.
All 30” models are equipped with a separate raise/lower switch. The switch must be installed
in a separate location outside of the vent and cooktop cutout.
2-1/4"
3-1/8"
10-1/2"
3-3/8"
3-3/4"
7-1/2"
6-1/4"
2"
8-1/2"
Lift
7-1/8"
Separate Raise/Lower Switch

ZVB30SH/BH/WH – GE Monogram 30" Telescopic Downdraft Vents
Specification Created 10/03
130658
Creative Solutions
For answers to your Monogram,® GE Profile™ or
GE
®
appliance questions, visit our website at
GEAppliances.com or call GE Answer Center
®
service, 800.626.2000.
Listed by
Underwriters
Laboratories
Against-the-wall installation
Move the base cabinet forward, 3" to 5".
Filler panels or complimentary moldings can
be added to the exposed cabinet sides.
Island or peninsula installation
Use an extra-deep countertop. The countertop
overhang at the front can be adjusted to meet
setback to cutout requirements.
Decorative trim
When the cutout to front edge of the
countertop requirement is more than 2",
add a bullnose trim to the front edge of the
countertop. The additional trim allows the
cooktop to be moved forward, providing
additional countertop depth and interior
cabinet space.
Base Cabinet
Filler Panel
Base Sink
Filler Panel
Maintain Cutout Clearances
to Front Edge as Specified
Cover Panel
Base Sink
End
Panel
Countertop Overhang per Cooktop
Clearances Must be Maintained
DOWNDRAFT
VENT
1-7/8"
Trim
Add a Bullnose
Trim or Decorative
Molding to
Increase
Countertop
Depth and to
Maintain
Required
Clearance From
Front Edge
Optional Accessories
JXRB67 Accessory for indoor remote location
of the blower/motor assembly. Use this kit
when the blower and motor assembly will
be located outside of the cabinet, such as
below the cabinet floor. The assembly will fit
between 16" floor joists.
JXBC67 Outdoor cover accessory for remote
installation of the blower/motor assembly on
an outside wall.
Ductwork
Prepare the ductwork to vent to the outdoors.
• Plan the shortest and straightest route for
venting exhaust to the outdoors.
• The maximum permissible length for the
duct run is 150 feet.
• Use metal ductwork only.
• The downdraft blower system is designed to
use 3-1/4" x 10" duct. It can be transitioned
to 6" round.
• Install a wall cap or roof cap with damper at
the exterior opening. Order the wall cap and
any transition needed in advance.

ZVB30SH/BH/WH – GE Monogram 30" Telescopic Downdraft Vents
Specification Created 10/03
130658
Venting Options
The downdraft vent is shipped with the
discharge outlet pointing straight down
and can be changed to a left- or right-side
discharge. For even more flexibility, the entire
blower and mounting plate can be adjusted
3-1/2" to the left or right sides.
Electrical and Gas Locations
Plan the placement of the electrical outlet
and gas (if used) carefully. Gas or electrical
outlets cannot be located on the back wall of
the cabinet because they may interfere with
the downdraft plenum.
• Install a standard electrical outlet within
reach of the vent’s two-foot-long power
cord. Locate the outlet inside the cabinet
on the right side wall.
• If the vent is installed in combination with a
Monogram® gas cooktop, it may operate
from the same 120V standard duplex outlet.
• If the vent is installed in combination with a
Monogram electric cooktop, the vent must
operate from a separate 120V outlet.
Discharge Down
(As Supplied)
34" for 36" Models
28-1/2" for 30" Models
29-1/2"
Electrical
Outlet
12" Above
Cabinet Floor
Do Not Locate Gas or Electrical
Connections Within Shaded Area
For answers to your Monogram,® GE Profile™ or
GE
®
appliance questions, visit our website at
GEAppliances.com or call GE Answer Center
®
service, 800.626.2000.
Listed by
Underwriters
Laboratories

ZVB30SH/BH/WH – GE Monogram 30" Telescopic Downdraft Vents
Specification Created 10/03
130658
Features and Benefits
• 30" Telescopic downdraft system
• 500 CFM performance
• Remote-mounted control
• Variable-speed fan with slide control
• Raises to 8-1/2" over cooktop surface
• Retracts when not in use
• Removable grease filters
• 3-1/4" x 10" rectangular duct
• Optional remote blower capabilities
• Stainless steel vent body
• Minimum 6" round duct capabilities
• Model ZVB30SHSS – Stainless steel (shown)
• Model ZVB30WHWW – White on white
• Model ZVB30BHBB – Black on black