Monogram ZV950SDSS Installation

Page 1
Installation Instructions
If you have questions, call 800.GE.CARES or visit our website at: www.monogram.com
ZV950
36" Stainless Steel Vent Hood
Page 2
Safety Information
BEFORE YOU BEGIN
Read these instructions completely and carefully.
• IMPORTANT– Save these instructions
for local inspector’s use.
• IMPORTANT – Observe all governing codes
and ordinances.
• Note to Installer – Be sure to leave these
instructions with the Consumer.
•
Note to Consumer – Keep these instructions
with your Owner’s Manual for future reference.
• Skill Level – Installation of this appliance requires basic mechanical and electrical skills.
• Completion time – 1 to 3 hours.
• Proper installation is the responsibility of the installer. Product failure due to improper installation is not cov­ered under the Warranty.
For Monogram local service in your area,
1.800.444.1845.
For Monogram service in Canada, call
1.800.561.3344.
For Monogram Parts and Accessories, call
1.800.626.2002.
CAUTION:
Due to the weight and size of these vent hoods, and to reduce the risk of personal injury or damage to the product, TWO PEOPLE ARE REQUIRED FOR PROPER
INSTALLATION.
PRUDENCE
À cause du poids et de la taille de ces hottes, et pour réduire le risque de blessures et de dommages, IL FAUT
DEUX PERSONNES POUR FAIRE L’INSTALLATION COR­RECTEMENT.
WARNING:
To reduce the risk of re or electrical shock, do not use this range hood with any external solid-state speed con­trol device. Any such alteration from original factory wiring could result in damage to the unit and/or create an electrical safety hazard.
AVERTISSEMENT
Pour réduire le risque d’incendie ou de choc électrique, il ne faut pas utiliser cette hotte avec un régulateur de vitesse électronique externe. Toute modication de ce type du branchement d’usine peut endommager l’appareil ou créer un risque de choc électrique.
WARNING: TO REDUCE THE RISK OF
manufacturer. If you have any questions, contact the manufacturer.
B. Before servicing or cleaning unit, switch
power o at the service panel and lock service panel to prevent power from being switched on accidentally. If the service panel cannot be locked, fasten a tag or prominent warning label to the panel.
AVERTISSEMENT
POUR RÉDUIRE LE RISQUE D’INCENDIE, DE CHOC ÉLECTRIQUE OU DE BLESSURES, IL FAUT OBSERVER LES RÈGLES SUIVANTES : A. Utiliser cet appareil uniquement de la manière
prévue par le fabricant. En cas de question, consulter le fabricant.
B. Avant toute intervention ou nettoyage, couper
l’alimentation électrique au disjoncteur et verrouiller le panneau du disjoncteur pour éviter la mise sous tension accidentelle. S’il n’est pas possible de verrouiller le panneau du disjoncteur, attacher un placard ou une étiquette très visible au panneau.
• For general ventilating use only. Do not use to exhaust hazardous or explosive materials or vapors.
• Structural framing, installation work and electrical wiring must be done by qualied person(s) in accordance with all applicable codes and standards including re-rated construction.
• Sucient air is needed for proper combustion and exhausting of gases through the ue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
• Local codes vary. Installation electrical connections and grounding must comply with applicable codes. In the absence of local codes, the vent should be installed in accordance with National Electrical Code
ANSI/NFPA 70-1990 or latest edition.
CAUTION: To reduce risk of re and to
properly exhaust air, be sure to duct air outside–Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces or garages.
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCT­WORK.
PRUDENCE–Il faut prendre soin d’installer
un conduit vers l’extérieur pour réduire le risque d’incendie et pouvoir évacuer l’air correctement. Il ne faut pas évacuer l’air dans l’espace entre les parois d’un mur, un plafond ou un grenier, un espace sanitaire ou un garage.
2
Page 3
Design Information
10"
*Height to Ceiling
35-5/8"
25"
Installation
Height Depending
on Ceiling Height
36" Min.
CONTENTS
Design Information
Product Dimensions and Clearances .......................................3–4
Optional Accessories ............................................................................4
Installation Preparation
Advance Planning,
Ductwork, Framing ..............................................................................5
Power Supply ............................................................................................5
Duct Fittings ..............................................................................................6
Tools and Materials Required ...........................................................7
Remove the Packaging ........................................................................7
Check Installation Hardware .............................................................8
PRODUCT DIMENSIONS AND CLEARANCES
36" Vent Hood Installation Combinations
This Stainless Steel Hood can be installed over any Mono­gram cooktop, including the Professional 36" rangetop and 30" or 36" range.
Ductwork, Wiring Locations ..............................................................8
Installation Instructions
Step 1, Install Framing for Hood Support ....................................9
Step 2, Install Mounting Brackets ...................................................9
Step 3, Install Duct Bracket ............................................................. 10
Step 4, Install the Hood ..................................................................... 10
Step 5, Connect Ductwork ............................................................... 11
Step 6, Connect Electrical ................................................................ 11
Step 7, Install Duct Covers ............................................................... 11
Step 8, Install Filters ............................................................................ 12
Step 9, Finalize Installation .............................................................. 12
Cooking surface to bottom of hood should be:
• 25-1/2" max. for 8 ft. ceiling height.
• 25-1/2" to 30" for 9 ft. ceiling height.
• 30" min. for 10 ft. ceiling height. Plan the installation height carefully to avoid unsightly gaps above the hood.
*The supplied duct cover ts 8 ft. to 10 ft . ceilings.
The vent hood must be installed 24" min. and 30" max. above the cooking surface. The hood installation height, from the cooking surface to the bottom of the hood, de­pends upon ceiling height.
This hood must be installed 30" min. above a Monogram Professional Cooktop or Range. Ceiling height for this in­stallation combination must be at least 8'5" high.
Note: The supplied 2-piece duct cover is adjustable to t 8 ft. to 10 ft. ceilings. For ceiling heights greater than 10 ft. and up to 14 ft., order ZX14SDSS stainless steel duct cover accessory.
ZV950SDSS Duct Cover Dimensions
ZX14SDSS Duct Cover Dimensions
3
Page 4
Design Information
PRODUCT DIMENSIONS AND CLEAR­ANCES (cont.)
Using Duct Cover Accessories
A Duct Cover Accessory may be required for your hood installation height. Use this chart to determine installa­tion height and accessory for your ceiling height.
ZV950SDSS Installation Heights
Actual Ceiling Height
7' 11"
8' 0" 8' 1" 8' 2" 8' 3" 8' 4" 8' 5" 8' 6" 8' 7" 8' 8"
8' 9" 8' 10" 8' 11"
9' 0"
9' 1"
9' 2'
9' 3'
9' 4"
9' 5"
9' 6"
9' 7"
9' 8"
9' 9" 9' 10" 9' 11" 10' 0"
* Possible Hood
Installation Height
24-1/2"
25-1/2" 25-1/2" to 26-1/2" 25-1/2" to 27-1/2" 25-1/2" to 28-1/2" 25-1/2" to 29-1/2"
25-1/2" to 30" 25-1/2" to 30" 25-1/2" to 30" 25-1/2" to 30" 25-1/2" to 30" 25-1/2" to 30" 25-1/2" to 30" 25-1/2" to 30" 26-1/2" to 30" 26-1/2" to 30" 26-1/2" to 30" 26-1/2" to 30" 26-1/2" to 30"
30" min. 30" min. 30" min. 30" min. 30" min. 30" min.
Duct Cover
SUPPLIED
OPTIONAL ACCESSORIES
ZX14SDSS, optional stainless steel duct cover is available
for ceiling heights greater than 10 ft. and up to 14 ft. Order the optional duct cover at the same time as the vent hood and have on site before installation. This kit contains hardware required for installation. This kit con­tains installation hardware.
Note: Duct covers must be installed as shown in this book. Do not “build-in” the duct cover. If service is required, the duct cover must be removed to access hood components.
30" min.
14' 0"
* Based on 36" countertop height.
The serial plate is located behind the removable lters.
ZX14SDSS
4
Page 5
Installation Preparation
ADVANCE PLANNING
Ductwork Planning
• Determine the exact location of the vent hood.
• Plan the route for venting exhaust to the outdoors.
• Use the shortest and straightest duct route possible. For satisfactory performance, duct run should not exceed 100 equivalent length for any duct congurations.
• Refer to “Duct Fittings” chart to compute the maximum permissible length for duct runs to the outdoors.
CAUTION: To reduce risk of re and to properly
exhaust air, be sure to duct air outside–Do not vent ex­haust air into spaces within walls or ceilings or into attics, crawl spaces or garages.
PRUDENCE – Il faut prendre soin d’installer un
conduit vers l’extérieur pour réduire le risque d’incendie et pouvoir évacuer l’air correctement. Il ne faut pas évacuer l’air dans l’espace entre les parois d’un mur, un plafond ou un grenier, un espace sanitaire ou un garage.
• Use metal ductwork. These hoods must use 8" round duct. It can transition to 3-1/4" x 12", reducing the maxi­mum equivalent duct length to 75 feet.
• Install a wall cap with damper or roof cap at the exterior opening. Order the wall or roof cap and any transition needed in advance.
Wall Framing for Adequate Support
• This vent hood is heavy. Adequate structural support must be provided. The hood must be secured to vertical studs in the wall, or to a horizontal support. See page 9.
• We strongly recommend that the vent hood with duct cover be on site before nal framing and wall nishing. This will also help to accurately locate the ductwork and electrical service.
POWER SUPPLY
IMPORTANT – (Please read carefully)
WARNING:
FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROP­ERLY GROUNDED.
AVERTISSEMENT
POUR DES RAISONS DE SÉCURITÉ, CET APPAREIL DOIT ÊTRE CORRECTEMENT MIS À LA TERRE.
Remove house fuse or open circuit breaker before beginning installation.
Do not use an extension cord or adapter plug with this ap­pliance. Follow National Electrical Code or prevailing local codes and ordinances.
Electrical supply
This vent hood must be supplied with 120V, 60Hz, and con­nected to an individual, properly grounded branch circuit, and protected by a 15 or 20 amp circuit breaker or time delay fuse.
• Wiring must be 2 wire with ground.
• If the electrical supply does not meet the above require­ments, call a licensed electrician before proceeding.
• Route house wiring as close to the installation location as possible in the ceiling or sot. Wiring should enter at least 4" above the bracket on the right side.
• Connect the wiring to the house wiring in accordance with local codes.
Grounding instructions
The grounding conductor must be connected to a ground metal, permanent wiring system, or an equipment­grounding terminal or lead on the hood.
WARNING: The improper connection of the
equipment-grounding conductor can result in a risk of electric shock. Check with a qualied electrician or service representative if you are in doubt whether the appliance is properly grounded.
AVERTISSEMENT
Le mauvais branchement du l de mise à la terre peut causer un choc électrique. En cas de doute, consulter un électricien qualié ou un technicien pour déterminer si l’appareil est à la terre.
5
Page 6
Installation Preparation
DUCT FITTINGS
This Hood Must Use 8" Round Duct. It Can Transition to
3-1/4" x 12" Duct.
Use this chart to compute maximum permissible lengths for duct runs to outdoors.
Note: Do not exceed maximum permissible equivalent lengths!
Maximum duct length: 100 ft. for range hoods.
Flexible ducting:
If exible metal ducting is used, all the equivalent feet values in the table should be doubled. The exible metal duct should be straight and smooth and extended as much as possible.
Equivalent Quantity Equivalent
Total
Duct Piece Dimensions Length* Used Length
Round, 1 ft.
straight length
90° elbow 17 ft.
45° elbow 10 ft.
3-1/4" x 12" 90° elbow 43 ft.
3-1/4" x 12" 45° elbow 26 ft.
3-1/4" x 12" 90° at elbow 102 ft.
straight (per foot
length) 1 ft.
3-1/4" x 12" (per foot
)
Do NOT use exible plastic ducting.
Note: Any home ventilation system, such as a ventilation hood, may interrupt the proper ow of combustion air and exhaust required by re­places, gas furnaces, gas water heaters and other naturally vented systems. To minimize the chance of interruption of such naturally vented systems, follow the heating equipment manufacturer’s guidelines and safety standards such as those published by NFPA and ASHRAE.
8" round to 3-1/4" x 12" transition 2 ft.
3-1/4" x 12" to 8" round transition 5 ft.
8" round to 3-1/4" x 12" transition 90° elbow 6 ft
3-1/4" x 12" to 8" round transition 90° elbow 13 ft.
wall cap with damper 32 ft.
3-1/4" x 12" wall cap with damper 75 ft.
Round roof cap 44 ft.
* Actual length of straight duct plus duct tting equivalent. Equiva-
lent length of duct pieces are based on actual tests conducted by GE Evaluation Engineering and reect requirements for good venting performance with any ventilation hood.
Round
.
Total Duct Run
6
Page 7
Installation Preparation
Top Shipping Screws
Junction
Box
Shipping Board
Remove Bottom Shipping
Screws and Shipping Bracket
TOOLS AND MATERIALS REQUIRED
(NOT SUPPLIED)
• Tape measure
• Knife
• Spirit level
• Wire cutter/stripper
• Wire nuts
• Electric drill with 1/8" and 3/8" bits
• Phillips and at blade screwdrivers
• Hammer
• Pliers
• Safety glasses
REMOVE THE PACKAGING
The hood is shipped secured to a shipping board with (4) screws. Remove the 4 screws. Two screws are located at the top of the hood. Two are located at the bottom of the hood behind the grease lters. A shipping bracket, which supports the blower, must also be removed. It is secured with two screws. All screw im­pressions are Phillips.
• Remove all packaging, the duct covers, and accessories.
• Lift the hood out of the carton.
• Remove and properly discard all plastic wrapping.
• Duct tape
• Tape to mount template
• Gloves to protect against sharp edges
• 120V 60Hz. 15 or 20 Amp, 2 wire with ground. Properly grounded branch circuit.
• Strain relief for junction cover.
• 8" round metal duct, length to suit installation.
Top Of Hood
• Remove junction box cover.
• Install strain relief into junction box cover.
7
Page 8
• Drill 1/8" Pilot Holes For Mounting Brackets.
Centerline 8" Min. Above Top Mounting Bracket Holes
6-1/4" Centerline To Wall
FOR WALL VENT DUCT
FOR CEILING VENT DUCTING
Align edge 25-1/2" above Cooking Surface.
17-1/2"
2-5/32"
C
L
5-7/8"
8-1/2" Dia. Hole
• Drill 1/8" Pilot Holes For Mounting Brackets.
Align edge 25-1/2" above Cooking Surface.
13-9/16"
2-5/32"
C L
C L
C L
5-7/8"
Installation Preparation
16"
23"
11"
24"
CHECK INSTALLATION HARDWARE
Locate the hardware accessory box packed with the hood and check contents.
10 Wood
Screws
2 Large
Flat Washers
2 Mounting Brackets with 4
Hex Head Leveling Screws
6 Wall
Fasteners
DUCTWORK, WIRING LOCATIONS
Determine the exact location of the vent hood.
• Locate the template packed with the literature. – Measure 36" from the oor to the top of the cooking
surface. Add 25-1/2" (or other recommended space) from the cooking surface to the bottom of the hood. Mark that location.
– Use a level to draw a straight pencil line on the wall.
3 Stainless Steel Grease Filters
Decorative Duct Cover
(dimension shown for reference only)
2-piece
2 Phillips Head
Decorative Screws
Duct Cover Bracket
Wall Mount Template
– Tape the template in position along the penciled line.
CHECK TO BE SURE THE TEMPLATE IS LEVEL.
Ceiling ducting:
If ductwork will vent straight up to the ceiling:
• Use a level to draw a line straight up, from the centerline on the template to the ceiling.
• Measure 6-1/4" from the back wall to the centerline of a 8-1/2" hole on the ceiling.
Note: If drywall is not present, add drywall thickness to the 6-1/4" dimension.
Wall Ducting:
If ductwork will vent to the rear:
• Use the level to draw a line straight up from the centerline on the template.
• Measure at least 8" above the top mounting bracket holes shown on the template to the centerline of an 8-1/2" dia. duct hole. (Hole may be elongated for duct elbow.)
HOUSE WIRING LOCATION:
• The junction box is located on the top of the hood, at the back right side.
• Route house wiring as close to the ceiling location as possible, through the ceiling, sot or back wall. Wiring should enter at least 4" above the bracket on the right side (no less than 18" above the planned lower edge of hood and ideally, 4" to the right of planned ductwork.)
8
Page 9
Installation Instructions
Centerline of Installation Space
8" Min. Opening for Ductwork
View From Rear
Cleats
1" x 6" Min.
Mounting
Support
Screws
“B”
Screws
“A”
1 INSTALL FRAMING
FOR HOOD SUPPORT
IMPORTANT: Framing must be capable of supporting 100 lbs.
2 INSTALL MOUNTING BRACKETS
This vent hood must be secured to the horizontal support or wall studs.
• With the template taped in place, use a punch to mark all mounting screw locations.
• Drill 1/8" pilot holes at the 6 punched locations.
• Remove the template.
• The 4 support bracket holes must enter studs or the horizontal support.
Note: Screws “A” and “B” are pre-assembled onto the brackets. Do not remove these screws.
• Secure the mounting brackets to the wall studs with wood screws provided.
If drywall is present, mark the screw hole locations for the top mounting brackets. Remove the template.
• Cutaway enough drywall to expose 2 vertical studs at the bracket location indicated on the template.
• Install a horizontal support at least 1" x 6" between two wall studs at the top bracket installation location. The
horizontal support must be ush with the room side of the studs. Use cleats behind both sides of the support
to secure the support to wall studs.
• Reinstall drywall.
9
Page 10
Pre-Tap Side Screw
Pre-Tap
Side
Screw
Bracket Tabs
Screws
“B”
Screws
“A”
Installation Instructions
3 INSTALL DUCT BRACKET
The duct bracket must be installed against the ceiling. This bracket will hold the decorative duct cover in place at the top.
• Install the 2 small screws into the sides of the duct bracket. Remove the screws. Pre-tapping the holes will insure ease of nal installation.
Secure the bracket to the ceiling and wall:
• Mark the 4 screw hole locations.
• Drill 1/8" pilot holes in marked bracket location.
• If pilot holes do not enter studs, enlarge the holes to 3/8" and install wall fastener anchors.
• Drive screws, by hand, into the fasteners to allow anchors to expand. Remove the screws.
• Secure the bracket to the ceiling and wall with wood screws and/or fasteners.
4 INSTALL THE HOOD
Place the hood on the brackets and slide left or right to center.
1. Adjust the installation levelness by tightening or loosening the screws “A” at the bottom of the brackets.
2. Mark the 2 lower mounting holes.
3. Remove the hood from the wall.
4. Drill a pilot hole in each lower mounting hole location. The two lower holes can be enlarged to 3/8" if they did enter studs. Tap anchors for wall fasteners into the bot­tom holes. Screws should be inserted by hand into the fasteners to allow anchors to expand against the wall material. Remove the screws for nal installation.
5. Replace the hood on the mounting brackets.
6. Using two large at washers (supplied), install wood screws or wall fastener screws.
7. Tighten screws “B” located at the top of the mounting bracket against the hood to clamp the position. Do not overtighten screws.
Lower Mounting Holes
10
Page 11
Installation Instructions
Mounting Screws
Screw
Duct Tape Over Seam and Screw
Air Flow
Duct Tape
Over Flange
Duct Stops
5 CONNECT DUCTWORK
• Install ductwork, making connections in direction of airow as illustrated.
• Push duct over the exhaust outlet until it reaches the duct stops.
• Secure joints in ductwork with sheetmetal screws.
• Wrap all duct joints with duct tape for an airtight seal.
• Use duct tape to seal the ange connection.
CAUTION: Do not use sheet metal screws at
the hood ange connection. Doing so will prevent proper damper operations. Seal connection with tape only.
PRUDENCE
Il ne faut pas utiliser de vis autoraurdeuses à la connexion du collet de la hotte. Ceci empêcherait le bon fonctionnement du registre. N’utiliser que du ruban adhésif pour assurer l’étanchéité du raccord.
6 CONNECT ELECTRICAL Verify that power is turned o at the source.
WARNING: If house wiring is not 2-wire with a
ground wire, a ground must be provided by the installer. When house wiring is aluminum, be sure to use U.L. ap­proved anti-oxidant compound and aluminum-to-copper connectors.
AVERTISSEMENT
Si la maison n’est pas câblée avec deux ls et un l de terre, l’installateur doit installer un l de terre. Quand les ls sont en aluminium, il faut prendre soin d’utiliser des con­necteurs aluminium à cuivre avec une pâte antioxydante approuvée par UL.
7 INSTALL DUCT COVERS
• Place the decorative duct covers on top of the hood.
• Insert the lower portion of the duct cover into the impressions on the top of the hood.
Bottom Notches
• Insert house wiring through strain relief and tighten.
• Connect white leads to branch circuit white lead.
• Connect black leads to branch circuit black lead.
• Connect green/yellow leads to branch circuit green lead or bare ground lead.
• Secure all connections with wire nuts on each electrical connector.
• Push wires into junction box and replace cover. Be sure wires are not pinched.
• Extend the inner duct upwards to the ceiling bracket.
• Secure the duct cover to the bracket with the 2 small Phillips screws provided.
11
Page 12
8 INSTALL FILTERS
• Remove protective lm on the lters.
Installation Instructions
• Tip the lter into the slots at the rear of the opening. Lift the lter and pull the knob forward until the lter rests on the slots.
• Install all 3 grease lters.
9 FINALIZE INSTALLATION
• Remove the protective lm covering the control panel on the front face of the hood, and any other packaging materials.
• Refer to the Owner’s Manual for operating instructions.
• To remove the lters, grasp the knob, push the lter to­wards the rear and tilt downwards.
• If the Clean Filter Reminder is glowing red after lters are installed, be sure to check the left side lter is making contact with the lter switch.
Pub. No. 31-14900
10-10 GE
Printed in Italy
Note: While performing installations described in this book, safety glasses or goggles should be worn.
For MonogramTM local service in your area, call
1.800.444.1845.
Note: Product improvement is a continuing endeavor at General Electric. Therefore, materials, appearance and specications are subject to change without notice.