• Note to Installer – Be sure to leave these instructions
with the Consumer.
• Note to Consumer – Keep these instructions for
future reference.
• Skill Level – Installation of this vent hood requires
basic mechanical and electrical skills.
• Completion time – 1 to 3 hours.
• Proper installation is the responsibility of the installer.
• Product failure due to improper installation is not
covered under the Warranty.
CAUTION:
Due to the weight and size of these vent hoods and
to reduce the risk of personal injury or damage to the
product, THREE PEOPLE ARE REQUIRED FOR PROPER
INSTALLATION.
PRUDENCE :
À cause du poids et des dimensions du ces hottes et
pour réduire les risques de blessures ou de dommages
du produit, IL FAUT TROIS PERSONNES POUR FAIRE
UNE INSTALLATION CORRECTE.
WARNING:
To reduce the risk of fire or electrical shock, do not use
this range hood with any external solid-state speed
control device. Any such alteration from original factory
wiring could result in damage to the unit and/or create
an electrical safety hazard.
AVERTISSEMENT :
Pour réduire le risque d’incendie ou de choc électrique,
il ne faut pas utiliser cette hotte avec un régulateur
de vitesse électronique externe. Toute modification de
ce type du branchement d’usine peute endommager
l’appareil ou créer un risque de choc électrique.
TO REDUCE THE RISK OF FIRE, USE ONLY METAL
DUCTWORK.
WARNING: TO REDUCE THE RISK OF FIRE,
ELECTRICAL SHOCK OR INJURY, OBSERVE THE FOLLOWING:
A. Use this unit only in the manner intended by the
manufacturer. If you have any questions, contact the
manufacturer.
B. Before servicing or cleaning unit, switch power off at the
service panel and lock service panel to prevent power from
being switched on accidentally. If the service panel cannot
be locked, fasten a tag or prominent warning label to the
panel.
AVERTISSEMENT :
POUR RÉDUIRE LE RISQUE D’INCENDIE, DE CHOC
ÉLECTRIQUE OU DE BLESSURES, IL FAUT OBSERVER LES
REGLES SUIVANTES :
A. Utilisez cet appareil uniquement de la maniére prévue par
le fabricant. En cas de question, consultez le fabricant.
B. Avant toute intervention ou nettoyage, coupez
l’alimentation électrique au disjoncteur et verrouiller
le panneau du disjoncteur pour éviter la mise sous
tension accidentelle. S’il n’est pas possible de verrouiller
le panneau du disjoncteur, attachez un placard ou une
étiquette trés visible au panneau.
• For general ventilating use only. Do not use to exhaust
hazardous or explosive materials or vapors.
• Structural framing, installation work and electrical wiring
must be done by qualified person(s) in accordance with
all applicable codes and standards, including fire-rated
construction.
• Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel
burning equipment to prevent back drafting. Follow the
heating equipment manufacturer’s guidelines and safety
standards such as those published by the National Fire
Protection Association (NFPA), and the American Society
for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities. When applicable,
install any makeup (replacement) air system in accordance
with local building code requirements. Visit GEAppliances.com for available makeup air solutions.
• Local codes vary. Installation of electrical connections
and grounding must comply with applicable codes. In
the absence of local codes, the vent should be installed
in accordance with National Electrical Code ANSI/NFPA
70-1990 or latest edition.
CAUTION: To reduce risk of fire and to properly
exhaust air, be sure to duct air outside. Do not vent exhaust
air into spaces within walls or ceilings or into attics, crawl
spaces or garages.
PRUDENCE : Il faut prendre soin d’installer
un conduit vers l’extérieur pour réduire le risque d’incendie
et pouvoir évacuer l’air correctement. Il ne faut pas évacuer
l’air dans l’espace entre les parois d’un mur, un plafond ou un
grenier, un espace sanitaire ou un garage.
* The supplied duct cover fits 7'-11" to 9' ceiling
heights. For 9'-1" to 10'-1" ceilings, order ZX92510.
These vent hoods are supplied with a support frame
for ceiling heights of 7'-11" to 10'-1".
Decorative duct covers conceal the ductwork running
from the top of the hood to the ceiling.
ZX92510 accessory is available for ceiling heights of
9'-1" to 10’-1".
35 7/8"
24"min.*
30"max.*
36"min.
* Exact installation
height depends
on ceiling height.
NOTE: Installation height should be measured from
the cooking surface to the bottom of the outer glass
portion of the hood.
This hood must be installed 24" min. and 30" max.
above the cooking surface. The cooking surface
should be at least 36" above the floor.
This hood may be vented to the outdoors, or it can be
installed for recirculating operation.
This hood can be installed over any Monogram
electric or gas cooktop. It cannot be installed over a
Monogram Professional cooktop or range.
3
Advance Planning
ADVANCE PLANNING
Ductwork Planning
• These vent hoods are equipped for 8" round
ductwork.
• Determine the exact location of the vent hood.
• Plan the route for venting exhaust to the outdoors.
• Use the shortest and straightest duct route
possible. For satisfactory performance, duct run
should not exceed 100 ft. equivalent length for any
duct configurations.
• Refer to “Duct Fittings” chart to compute the
maximum permissible length for duct runs to the
outdoors.
• Use rigid metal ductwork only.
• Install a roof cap with damper at the exterior
opening. Order the cap and any transitions needed
in advance.
• When applicable, install any makeup (replacement)
air system in accordance with local building code
requirements. Visit GEAppliances.com for available
makeup air solutions.
Ceiling Framing for Adequate Support
• These vent hoods are heavy. Adequate structural
support must be provided. The ceiling structure
must be capable of supporting the weight of the
hood and any inadvertent user contact loads
(approximately 200 pounds). The hood support
frame will be supported by 2 x 4 cross framing.
• Installation will be easier if the vent hood is
installed before the cooktop or countertop below is
installed.
Accessory Duct Cover
• All models are shipped with a duct cover for ceiling
heights of 7'-11" to 9'.
ZX92510 accessory 36-3/4"duct cover is
available to reach 9'-1"to 10'-1" ceiling heights.
The accessory should be ordered with the hood
and be on site before final framing and wall
finishing.
POWER SUPPLY
IMPORTANT - (Please read carefully)
WARNING:
FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE
PROPERLY GROUNDED.
ATTENTION : POUR DES RAISONS DE
SÉCURITÉ, CET APPAREIL DOIT ÊTRE CORRECTEMENT
MIS À LA TERRE.
Remove house fuse or open circuit breaker before
beginning installation.
Do not use an extension cord or adapter plug with
this appliance. Follow National electrical codes or
prevailing local codes and ordinances.
Electrical Supply
This vent hood must be supplied with 120V, 60Hz,
and connected to an individual, properly grounded
branch circuit, and protected by a 15 or 20 amp
circuit breaker or time delay fuse.
• Wiring must be 2 wire with ground.
• If the electrical supply does not meet the above
requirements, call a licensed electrician before
proceeding.
• Route house wiring in the ceiling, as close to the
installation location as possible. Allow additional
length from ceiling joists to reach the junction
box on the bottom of the hood support frame.
• Connect the wiring to the house wiring in
accordance with local codes.
Grounding Instructions
The grounding conductor must be connected to
a ground metal, permanent wiring system, or an
equipment-grounding terminal or lead on the hood.
WARNING: The improper connection of
equipment-grounding conductor can result in a risk
of electric shock. Check with a qualified electrician
or service representative if you are in doubt
whether the appliance is properly grounded.
AVERTISSEMENT :
Le mauvais branchement du fil de mise à la terre
peut causer un choc électrique. En cas de doute,
consultez un électricien qualifié ou un technicien
pour déterminer si l’appareil est à la terre.
4
Advance Planning
DUCT FITTINGS
This Hood Must Use an
8d Round Duct. It Can
Transition to a
3-1/4d x 12d Duct.
Use this chart to compute
maximum permissible lengths for
duct runs to outdoors.
NOTE: Do not exceed maximum
permissible equivalent lengths!
Maximum duct length:
100 foot for range hoods.
Flexible ducting:
If flexible metal ducting is used,
all the equivalent feet values in
the table should be doubled.
The flexible metal duct should
be straight and smooth and
extended as much as possible.
DO NOT use flexible plastic
ducting.
NOTE: Any home ventilation
system, such as a ventilation
hood, may interrupt the proper
flow of combustion air and
exhaust required by fireplaces, gas
furnaces, gas water heaters and
other naturally vented systems.
To minimize the chance of
interruption of such naturally
vented systems, follow the
heating equipment manufacturer’s
guidelines and safety standards
such as those published by NFPA
and ASHRAE. When applicable,
install any makeup (replacement)
air system in accordance with local
building code requirements. Visit
GEAppliances.com for available
makeup air solutions.
Total
Equivalent Quantity Equivalent
Duct Piece Dimensions Length* Used Length
Round, 1 ft.
straight (per foot
length)
3-1/4" x 12" 1 ft.
straight (per foot
length)
90° elbow
17 ft.
45° elbow
10 ft.
ø[90° elbow 43 ft.
3-1/4" x 12"
45° elbow 26 ft.
3-1/4" x 12"
90° flat elbow 102 ft.
8" round to
3-1/4" x 12" transition 2 ft.
3-1/4" x 12" to 8"
round transition 5 ft.
8" round
to 3-1/4" x 12"
transition 90° elbow 6 ft.
3-1/4" x 12" to 8" round
round transition 90° elbow 13 ft.
Round
wall cap
with damper 32 ft.
3-1/4" x 12" wall cap
with damper 75 ft.
Round
roof cap 44 ft.
* Actual length of straight duct plus duct fitting
equivalent. Equivalent length of duct pieces are
based on actual tests conducted by GE Evaluation
Engineering and reflect requirements for good
venting performance with any ventilation hood.
Total Duct Run
5
Installation Preparation
DETERMINE INSTALLATION HEIGHT
• Decorative duct covers are provided to conceal the
ductwork running to the ceiling.
• This hood can be installed for recirculating
operation. No kits required.
The hood installation height, from the cooking
surface to the bottom of the hood, depends upon
ceiling height.
For optimum performance, the hood must be 24"
min. and 30" max. above the cooking surface.
Use the chart on this page to accurately determine
installation height and support frame adjustment,
and to select the correct size top trim piece (A, B, C
or D).
D
C
B
A
ZX92510 Accessory Duct cover includes a 36-3/4"
long duct cover and 3 sets of duct cover top trim
pieces labeled E, F, G.
Possible Hood Mounting
Ceiling Installation Frame Trim Piece
Height Height (inches) Height (inches) Needed
7'-11" 26 30 1/2 A
8'
8'-1" 24 34 1/2 B
8'-1" 28 30 1/2 A
8'-2" 25 34 1/2 B
8'-2" 29 30 1/2 A
8'-3" 26 34 1/2 B
8'-3" 30 30 1/2 A
8'-4" 27 34 1/2 B
8'-5" 24 38 1/2 C
8'-5" 28 34 1/2 B
8'-6" 25 38 1/2 C
8'-6" 29 34 1/2 B
8'-7" 26 38 1/2 C
8'-7" 30 34 1/2 B
8'-8" 27 38 1/2 C
8'-9" 24 42 1/2 D
8'-9" 28 38 1/2 C
8'-10" 25 42 1/2 D
8'-10" 29 38 1/2 C
8'-11" 26 42 1/2 D
8'-11" 30 38 1/2 C
9' 27 42 1/2 D
ZX92510 Accessory Duct Cover
9'-1" 24 46 1/2 E
9'-1"d 28 42 1/2 D
9'-2" 25 46 1/2 E
9'-2" 29 42 1/2 D
9'-3" 26 46 1/2 E
9'-3" 30 42 1/2 D
9'-4" 27 46 1/2 E
9'-5" 24 50 1/2 F
9'-5" 28 46 1/2 E
9'-6" 25 50 1/2 F
9'-6" 29 46 1/2 E
9'-7" 26 50 1/2 F
9'-7" 30 46 1/2 E
9'-8" 27 50 1/2 F
9'-9" 24 54 1/2 G
9'-9" 28 50 1/2 F
9'-10" 25 54 1/2 G
9'-10" 29 50 1/2 F
9'-11" 26 54 1/2 G
9'-11" 30 50 1/2 F
10' 27 54 1/2 G
10'-1" 28 54 1/2 G
27 30 1/2 A
6
Installation Preparation
TOOLS AND MATERIALS REQUIRED
(NOT SUPPLIED)
Duct tape
Pencil and tape measure
Spirit level
Step ladder
Carpenter’s square
Wire cutter/stripper
Safety glasses
Saber saw
or sawsall
Pliers
socket or pivoting
hex socket with 6"
Metal snips
3/8" swivel
extensions
Wire nuts
Flashlight
Hammer
Key hole saw
Electric or battery-operated
drill and 3/16" bits, Phillips and
flat blade screwdriver bits.
8" round metal
duct, length to
suit installation.
Phillips and
flat blade
screwdrivers
Strain relief for
junction cover.
120V 60Hz. 15 or 20 Amp,
2-wire with ground. properly
grounded branch circuit.
REMOVE THE PACKAGING
CAUTION: LIFT THE HOOD OUT OF THE
BOX BY THE CENTER METAL PORTION. DO NOT LIFT
BY THE GLASS SIDES.
PRUDENCE :LEVEZ LA HOTTE À
L’EXTÉRIEUR DE LA BOÎTE PAR LA PORTION MÉTAL
CENTRAL. NE LEVEZ PAS PAR LES CÔTÉS DE VERRE.
CAUTION:Wear gloves to protect
against sharp edges.
PRUDENCE :Portez des gants pour
éviter les blessures causées par les tranchants.
• Grasp the hood by the metal insert in the center
and lift straight up and out of the box.
• Remove and properly discard the plastic wrapping.
• Remove parts box, duct covers and other
packaging.
7
Installation Preparation
PARTS PROVIDED
Locate the parts packed with the hood.
Air deflector for
recirculating installation
HARDWARE PACKAGE
Locate and check
contents. Screws
shown actual size.
12 sheet
42 screws total:
• 24 support frame
screws
• 10 hood attachment
screws
• 2 upper duct cover
attachment screws
• 4 recirculating
deflector screws
• 2 duct cover bracket
attachment screws
Stainless steel filter
metal
screws
2 Duct cover
brackets
6 ceiling
mounting
screws
12 cage
nuts
2 thumb
screws
1 charcoal filter for
recirculating installation
Telescoping
support frame
Upper duct cover trim pieces
2 each of 4 sizes
Lower duct cover trim pieces
Note: Some additional hardware/screws included.
Drill 3/16≤
7-1/16≤ to
Centerline
of Holes
49-80406
Printed in Italy 04-06 JR
Pilot Holes
Approx. 1-1/2≤
Deep
Cut a 1≤Dia.
Wire Access
Hole
36≤ Hood
Template
≤Dia.
8-1/2
10-1/16≤ to
Centerline
of Holes
FRONT OF HOOD
Cut a 1≤Dia.
Wire Access
Hole
7-1/16≤ to
Centerline
of Holes
Drill 3/16≤
Pilot Holes
Approx. 1-1/2≤
Deep
Template
8
24-3/4"
23-1/4"
Decorative duct covers
(14"wide, 12-3/16" deep when assembled)
Installation Preparation
CONSTRUCT CEILING SUPPORT
Plan the Location of the Hood and Ductwork
• Use a plumb bob to check the location. The
countertop/cooktop below the hood must be
centered with the hood.
Ceiling
Hood
ducting
centerline
Front
13-3/4"
27-9/16"
Align with
center of
cooktop
Side view
• The hood should extend beyond the front and rear
edge of the cooking appliance.
• The duct in the ceiling must be centered over the
cooktop.
Cooktop
Countertop
Ceiling Support Structure
• At the hood location, install 2 x 4 cross framing
between ceiling joists as shown. (2x4’s are required to
support the weight of the hood.)
10-1/16"
Install cross-framing
EXAMPLE A
symmetrically over
duct/cooktop
centerline
16" joist
7-1/16"
8” duct
spacing
• Arrange cross framing in the ceiling to suit the
existing structure.
• Your ceiling joists will be like one of the following
examples.
2x4 cross
framing
Front
of
hood
Align duct
to center of
cooktop
Top view – ceiling joists parallel to front of hood
9
Cooktop
outline