GE ZV900SLSS User Manual

Installation Instructions
36" Glass Canopy Chimney Vent Hood
ZV900
49-80328-3
Safety Information
Read these instructions completely and carefully.
IMPORTANT³ Save these instructions for
local inspector’s use.
IMPORTANT³ Observe all governing codes
and ordinances.
Note to Installer³Be sure to leave these
instructions with the Consumer.
Note to Consumer³ Keep these instructions
with your Owner’s Manual for future reference.
Skill Level³Installation of this appliance requires
basic mechanical and electrical skills.
Completion Time³WR+RXUV
Proper installation is the responsibility of the installer.
Product failure due to improper installation is not covered under the warranty.
For Monogram local service in your area, call
 )RU0RQRJUDPVHUYLFHLQ&DQDGDFDOO
For Monogram Parts and Accessories, call

CAUTION:
Due to the weight and size of these vent hoods and to reduce the risk of personal injury or damage to the product, TWO PEOPLE ARE REQUIRED FOR PROPER
INSTALLATION.
PRUDENCE :
À cause du poids et de la taille de ces hottes et pour reduire le risque de blessures et de dommages, IL
FAUT DEUX PERSONNES POUR FAIRE L’INSTALLATION CORRECTEMENT.
WARNING:
To reduce the risk of fire or electrical shock, do not use this range hood with any external solid-state speed control device. Any such alteration from original factory wiring could result in damage to the unit and/or create an electrical safety hazard.
AVERTISSEMENT :
Pour réduire le risque d’incendie ou de choc électrique, il ne faut pas utiliser cette hotte avec un régulateur de vitesse électronique externe. Toute modification de ce type du branchement d’usine peute endommager l’appareil ou créer un risque de choc électrique.
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK.
WARNING: TO REDUCE THE RISK OF
FIRE, ELECTRICAL SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. Use this unit only in the manner intended by the
manufacturer. If you have any questions, contact the manufacturer.
B. Before servicing or cleaning unit, switch power off at
the service panel and lock service panel to prevent power from being switched on accidentally. If the service panel cannot be locked, fasten a tag or prominent warning label to the panel.
AVERTISSEMENT :
POUR RÉDUIRE LE RISQUE D’INCENDIE, DE CHOC ÉLECTRIQUE OU DE BLESSURES, IL FAUT OBSERVER LES REGLES SUIVANTES :
A. Utiliser cet appareil uniquement de la maniére
prévue par le fabricant. En cas de question, consulter le fabricant.
B. Avant toute intervention ou nettoyage, couper
l’alimentation électrique au disjoncteur et verrouiller le panneau du disjoncteur pour éviter la mise sous tension accidentelle. S’il n’est pas possible de verrouiller le panneau du disconcteur, attacher un placard ou une étiquette trés visible au panneau.
• For general ventilating use only. Do not use to exhaust hazardous or explosive materials or vapors.
• Structural framing, installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards including fire-rated construction.
• Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. When applicable, install any makeup (replacement) air system in accordance with local building code requirements. Visit GEAppliances.com for available makeup air solutions.
• Local codes vary. Installation of electrical connections and grounding must comply with applicable codes. In the absence of local codes, the vent should be installed in accordance with National Electrical Code ANSI/NFPA 70-1990 or latest edition.
CAUTION: To reduce risk of fire and to
SURSHUO\H[KDXVWDLUEHVXUHWRGXFWDLURXWVLGH³GRQRW
vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces or garages.
PRUDENCE : Il faut prendre soin
d’installer un conduit vers l’extérieur pour réduire le risque d’incendie et pouvoir évacuer l’air correctement. Il ne faut pas évacuer l’air correctement. Il ne faut pas évacuer l’air dans l’espace entre les parois d’un mur, un plafond ou un grenier, un espace sanitaire ou un garage.
2
Design Information
CONTENTS
Design Information
Product Dimensions and Clearances ....................................................3
Installation Options ........................................................................................3
Installation Preparation
Advance Planning, Ductwork, Framing ................................................4
Power Supply ....................................................................................................4
Duct Fittings .......................................................................................................5
Tools and Materials Required ....................................................................6
Remove the Packaging.................................................................................6
Determine Installation Height ...................................................................7
Wall Mount Installation Heights ...............................................................7
Check Installation Hardware .....................................................................8
,QVWDOODWLRQ³9HQWHGWRWKH2XWVLGH
Ductwork, Wiring Locations .......................................................................9
Step 1, Install Framing for Hood Support ............................................9
Step 2, Install Mounting Bracket ........................................................... 10
Step 3, Install Duct Bracket .....................................................................10
Step 4, Prepare the Hood ......................................................................... 11
Step 5, Mount the Hood ............................................................................ 12
Step 6, Level the Hood ...............................................................................12
Step 7, Connect Ductwork .......................................................................12
Step 8, Connect Electrical ......................................................................... 13
Step 9, Install Duct Covers ....................................................................... 14
Step 10, Install Filters..................................................................................14
Step 11, Finalize Installation ................................................................... 14
,QVWDOODWLRQ³5HFLUFXODWLQJ
Ductwork, Wiring Locations .................................................................... 15
Step 1, Install Framing for Hood Support ......................................... 15
Step 2, Install Mounting Bracket ........................................................... 16
Step 3, Install Duct Bracket .....................................................................16
Step 4, Prepare the Hood ......................................................................... 17
Step 5, Mount the Hood ............................................................................ 17
Step 6, Level the Hood ...............................................................................17
Step 7, Size and Cut Duct Piece ............................................................18
Step 8, Connect Electrical ......................................................................... 18
Step 9, Install Duct Covers ....................................................................... 19
Step 10, Install Filters..................................................................................19
Step 11, Finalize Installation ................................................................... 19
PRODUCT DIMENSIONS AND CLEARANCES
*Height
*Height
to
to
Ceiling
Ceiling
3 1/4”
3 1/4"
35 7/8”
7/16"
20 7/16”
* The Supplied Duct Cover Fits 8' to 9'-5"Ceiling
Heights. For 9'-6" to 10'-5" ceilings, order ZX90010.
7KHYHQWKRRGPXVWEHLQVWDOOHGPLQDQG
d max. above the cooking surface. The hood

installation height above the cooking surface depends upon ceiling height.
The telescopic duct cover conceals the ductwork running from the top of the hood to the ceiling.
7KHVXSSOLHGGXFWFRYHULVVL]HGWRUHDFKWR
ceiling heights.
7KH=;DFFHVVRU\LVDYDLODEOHIRUFHLOLQJ KHLJKWVRIWR
35 7/8"
INSTALLATION OPTIONS
24” Min.
30” Max.
NOTE: Installation height should be measured from the cooking surface to the outer glass sides.
This hood may be installed onto a wall and vented to the outdoors, or it can be installed for recirculating operation. All necessary parts for recirculating operation are supplied with th e hood. No kits required.
This hood can be installed over any Monogram electric cooktop or gas cooktop. It cannot be installed over a Monogram Professional cooktop or range.
3
Installation Preparation
ADVANCE PLANNING
• Determine the exact location of the vent hood.
• Plan the route for venting exhaust to the outdoors.
• Use the shortest and straightest duct route possible. For satisfactory performance, duct run should not exceed 100 ft. equivalent length for any duct configurations.
• Refer to “Duct Fittings” chart to compute the maximum permissible length for duct runs to the outdoors.
When applicable, install any makeup (replacement) air system in accordance with local building code requirements. Visit GEAppliances.com for available makeup air solutions.
CAUTION: To reduce risk of fire and to properly
H[KDXVWDLUEHVXUHWRGXFWDLURXWVLGH³GRQRWYHQWH[KDXVW
air into spaces within walls or ceilings or into attics, crawl spaces or garages.
PRUDENCE : Il faut prendre soin d’installer un
conduit vers l’extérieur pour réduire le risque d’incendie et pouvoir évacuer l’air correctement. Il ne faut pas évacuer l’air correctement. Il ne faut pas évacuer l’air dans l’espace entre les parois d’un mur, un plafond ou un grenier, un espace sanitaire ou un garage.
• Use metal ductwork only. These hoods must use 8" round duct.
• Install a wall cap with damper or roof cap at the exterior opening. Order the wall or roof cap and any transition needed in advance.
Wall Framing for Adequate Support
• This vent hood is heavy. Adequate structural support must be provided in all types of installations. The hood must be secured to vertical studs in the wall, or to a horizontal support.
• The vent hood should be on site before final framing and wall finishing. This will help to accurately locate the duct work and electrical service.
• Installation will be easier if the vent hood is installed before the cooktop and countertop are installed.
Accessory Duct Cover
• This hood is shipped with a decorative duct cover for ceiling heights of 7’-11" to 9'-5". ZX90010 duct cover accessory is available to reach 9'-6" to 10'-5" ceiling heights. The accessory should be ordered with the hood and be on site before installation begins.
POWER SUPPLY
IMPORTANT – (Please read carefully)
WARNING: FOR PERSONAL SAFETY, THIS
APPLIANCE MUST BE PROPERLY GROUNDED.
AVERTISSEMENT : POUR DES RAISONS DE
SÉCURITÉ, CET APPAREIL DOIT ÊTRE CORRECTEMENT MISE À LA TERRE.
Remove house fuse or open circuit breaker before beginning installation.
Do not use an extension cord or adapter plug with this appliance. Follow National electrical codes or prevailing local codes and ordinances.
Electrical supply
These vent hoods must be supplied with 120V, 60Hz, and connected to an individual, properly grounded branch circuit, and protected by a 15 or 20 amp circuit breaker or time delay fuse.
• Wiring must be 2 wire with ground.
• If the electrical supply does not meet the above requirements, call a licensed electrician before proceeding.
• Route house wiring as close to the installation location as possible, in the ceiling or back wall.
• Connect the hood wiring to the house wiring in accordance with local codes.
Grounding instructions
The grounding conductor must be connected to a grounded metal, permanent wiring system, or an equipment-grounding terminal or lead on the hood.
WARNING: The improper connection of the
equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative if you are in doubt whether the appliance is properly grounded.
AVERTISSEMENT : Le mauvais
branchement du fil de mise à la terre peut causer un choc électrique. En cas de doute, consulter un électricien qualifié ou un technicien pour déterminer si l’appareil est à la terre.
CAUTION: Automatically Operated Device –
To reduce the risk of injury disconnect from power supply before servicing. This unit is equipped with an integral disconnecting switch located inside the blower housing.
PRUDENCE : Appareil commandé
automatiquement. Afin de réduire les risques de blessure, débranchez l’appareil de l’alimentation électrique avant de procéder à une réparation. L’appareil est équipé d’un sectionneur intégral situé à l’intérieur du logement du ventilateur.
4
Installation Preparation
DUCT FITTINGS
This Hood Must Use an
d Round Duct. It Can
Transition to a
d[d Duct.
Use this chart to compute maximum permissible lengths for duct runs to outdoors.
NOTE: Do not exceed maximum permissible equivalent lengths!
Maximum duct length:
IRRWIRUUDQJHKRRGV
Flexible ducting:
If flexible metal ducting is used, all the equivalent feet values in the table should be doubled. The flexible metal duct should be straight and smooth and extended as much as possible.
DO NOT use flexible plastic ducting.
NOTE: Any home ventilation system, such as a ventilation hood, may interrupt the proper flow of combustion air and exhaust required by fireplaces, gas furnaces, gas water heaters and other naturally vented systems. To minimize the chance of interruption of such naturally vented systems, follow the heating equipment manufacturer’s guidelines and safety standards such as those published by NFPA and ASHRAE. When applicable, install any makeup (replacement) air system in accordance with local building code requirements. Visit GEAppliances.com for available makeup air solutions.
Total Equivalent Quantity Equivalent Duct Piece Dimensions Length* Used Length
Round, 1 ft. straight (per foot length)
3-1/4" x 12" 1 ft. straight (per foot length)
90° elbow 17 ft.
45° elbow 10 ft.
ø[ 90° elbow 43 ft.
3-1/4" x 12" 45° elbow 26 ft.
3-1/4" x 12" 90° flat elbow 102 ft.
8" round to 3-1/4" x 12" transition 2 ft.
3-1/4" x 12" to 8" round transition 5 ft.
8" round to 3-1/4" x 12" transition 90° elbow 6 ft.
3-1/4" x 12" to 8" round transition 90° elbow 13 ft.
Round wall cap with damper 32 ft.
3-1/4” x 12" wall cap with damper 75 ft.
Round roof cap 44 ft.
* Actual length of straight duct plus duct fitting
equivalent. Equivalent length of duct pieces are based on actual tests conducted by GE Evaluation Engineering and reflect requirements for good venting performance with any ventilation hood.
Total Duct Run
5
Installation Preparation
TOOLS AND MATERIALS REQUIRED
(NOT SUPPLIED)
Tape measure Knife Spirit level Wire cutter/stripper Wire nuts Electric drill with 5/16" and 3/8" bits Phillips and flat blade screwdrivers Hammer Pliers Safety glasses Duct tape Tape to mount template Gloves to protect against sharp edges 120V 60Hz. 15 or 20 Amp, 2 wire with
ground Properly grounded branch circuit
Strain relief for junction cover 8" round metal duct, length to suit
installation
Saw, jig saw or reciprocating saw
Measuring tape
Pliers
Duct tape
Strain relief
12” long Phillips head screwdriver
Spirit level
Electric drill with 5/16” and 3/8” Bits
Safety glasses
Gloves
Knife
Wire cutter/
stripper
Hammer
Flat blade
screwdriver
Wire nuts
REMOVE THE PACKAGING
CAUTION: LIFT THE HOOD OUT OF THE BOX
BY THE CENTER METAL PORTION. DO NOT LIFT BY THE GLASS SIDES.
PRUDENCE : LEVEZ LA HOTTE À
L’EXTÉRIEUR DE LA BOÎTE PAR LA PORTION MÉTAL CENTRAL. NE LEVEZ PAS PAR LES CÔTÉS DE VERRE.
CAUTION: Wear gloves to protect against
sharp edges.
PRUDENCE : Portez des gants pour éviter
les blessures causées par les tranchants.
Masking tape
• Grasp the hood by the metal insert in the center and lift straight up and out of the box.
• Remove and properly discard the plastic wrapping.
• Remove parts box, duct covers and other packaging.
Saw, jig saw or
reciprocating
saw
8" round metal
duct, length to suit
installation
6