Due to the weight and size of these vent hoods and
to reduce the risk of personal injury or damage to the
product, TWO PEOPLE ARE REQUIRED FOR PROPER
INSTALLATION.
PRUDENCE :
À cause du poids et de la taille de ces hottes et pour
reduire le risque de blessures et de dommages, IL
FAUT DEUX PERSONNES POUR FAIRE L’INSTALLATION
CORRECTEMENT.
WARNING:
To reduce the risk of fire or electrical shock, do not
use this range hood with any external solid-state speed
control device. Any such alteration from original factory
wiring could result in damage to the unit and/or create
an electrical safety hazard.
AVERTISSEMENT :
Pour réduire le risque d’incendie ou de choc électrique,
il ne faut pas utiliser cette hotte avec un régulateur de
vitesse électronique externe. Toute modification de ce
type du branchement d’usine peute endommager
l’appareil ou créer un risque de choc électrique.
TO REDUCE THE RISK OF FIRE, USE ONLY METAL
DUCTWORK.
WARNING:TO REDUCE THE RISK OF
FIRE, ELECTRICAL SHOCK OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
A. Use this unit only in the manner intended by the
manufacturer. If you have any questions, contact the
manufacturer.
B. Before servicing or cleaning unit, switch power off at
the service panel and lock service panel to prevent
power from being switched on accidentally. If the
service panel cannot be locked, fasten a tag or
prominent warning label to the panel.
AVERTISSEMENT :
POUR RÉDUIRE LE RISQUE D’INCENDIE, DE CHOC
ÉLECTRIQUE OU DE BLESSURES, IL FAUT OBSERVER LES
REGLES SUIVANTES :
A. Utiliser cet appareil uniquement de la maniére
prévue par le fabricant. En cas de question, consulter
le fabricant.
B. Avant toute intervention ou nettoyage, couper
l’alimentation électrique au disjoncteur et verrouiller
le panneau du disjoncteur pour éviter la mise
sous tension accidentelle. S’il n’est pas possible de
verrouiller le panneau du disconcteur, attacher un
placard ou une étiquette trés visible au panneau.
• For general ventilating use only. Do not use to
exhaust hazardous or explosive materials or vapors.
• Structural framing, installation work and electrical
wiring must be done by qualified person(s)
in accordance with all applicable codes and
standards including fire-rated construction.
• Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel
burning equipment to prevent back drafting. Follow
the heating equipment manufacturer’s guidelines
and safety standards such as those published by the
National Fire Protection Association (NFPA), and the
American Society for Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code
authorities. When applicable, install any makeup
(replacement) air system in accordance with local
building code requirements. Visit GEAppliances.com
for available makeup air solutions.
• Local codes vary. Installation of electrical
connections and grounding must comply with
applicable codes. In the absence of local codes, the
vent should be installed in accordance with National
Electrical Code ANSI/NFPA 70-1990 or latest edition.
vent exhaust air into spaces within walls or ceilings or
into attics, crawl spaces or garages.
PRUDENCE : Il faut prendre soin
d’installer un conduit vers l’extérieur pour réduire le
risque d’incendie et pouvoir évacuer l’air correctement.
Il ne faut pas évacuer l’air correctement. Il ne faut pas
évacuer l’air dans l’espace entre les parois d’un mur, un
plafond ou un grenier, un espace sanitaire ou un garage.
2
Design Information
CONTENTS
Design Information
Product Dimensions and Clearances ....................................................3
NOTE: Installation height should be measured from
the cooking surface to the outer glass sides.
This hood may be installed onto a wall and vented
to the outdoors, or it can be installed for recirculating
operation. All necessary parts for recirculating
operation are supplied with th e hood. No kits
required.
This hood can be installed over any Monogram
electric cooktop or gas cooktop. It cannot be
installed over a Monogram Professional cooktop
or range.
3
Installation Preparation
ADVANCE PLANNING
• Determine the exact location of the vent hood.
• Plan the route for venting exhaust to the outdoors.
• Use the shortest and straightest duct route possible. For
satisfactory performance, duct run should not exceed 100 ft.
equivalent length for any duct configurations.
• Refer to “Duct Fittings” chart to compute the maximum
permissible length for duct runs to the outdoors.
•
When applicable, install any makeup (replacement)
air system in accordance with local building code
requirements. Visit GEAppliances.com for available
makeup air solutions.
air into spaces within walls or ceilings or into attics, crawl
spaces or garages.
PRUDENCE : Il faut prendre soin d’installer un
conduit vers l’extérieur pour réduire le risque d’incendie et
pouvoir évacuer l’air correctement. Il ne faut pas évacuer l’air
correctement. Il ne faut pas évacuer l’air dans l’espace entre
les parois d’un mur, un plafond ou un grenier, un espace
sanitaire ou un garage.
• Use metal ductwork only. These hoods must use
8" round duct.
• Install a wall cap with damper or roof cap at the exterior
opening. Order the wall or roof cap and any transition
needed in advance.
Wall Framing for Adequate Support
• This vent hood is heavy. Adequate structural support must
be provided in all types of installations. The hood must
be secured to vertical studs in the wall, or to a horizontal
support.
• The vent hood should be on site before final framing and
wall finishing. This will help to accurately locate the duct
work and electrical service.
• Installation will be easier if the vent hood is installed before
the cooktop and countertop are installed.
Accessory Duct Cover
• This hood is shipped with a decorative duct cover for ceiling
heights of 7’-11" to 9'-5". ZX90010 duct cover accessory
is available to reach 9'-6" to 10'-5" ceiling heights. The
accessory should be ordered with the hood and be on site
before installation begins.
POWER SUPPLY
IMPORTANT – (Please read carefully)
WARNING: FOR PERSONAL SAFETY, THIS
APPLIANCE MUST BE PROPERLY GROUNDED.
AVERTISSEMENT : POUR DES RAISONS DE
SÉCURITÉ, CET APPAREIL DOIT ÊTRE CORRECTEMENT MISE
À LA TERRE.
Remove house fuse or open circuit breaker before beginning
installation.
Do not use an extension cord or adapter plug with this
appliance. Follow National electrical codes or prevailing local
codes and ordinances.
Electrical supply
These vent hoods must be supplied with 120V, 60Hz, and
connected to an individual, properly grounded branch circuit,
and protected by a 15 or 20 amp circuit breaker or time delay
fuse.
• Wiring must be 2 wire with ground.
• If the electrical supply does not meet the above
requirements, call a licensed electrician before proceeding.
• Route house wiring as close to the installation location as
possible, in the ceiling or back wall.
• Connect the hood wiring to the house wiring in accordance
with local codes.
Grounding instructions
The grounding conductor must be connected to a grounded
metal, permanent wiring system, or an equipment-grounding
terminal or lead on the hood.
WARNING: The improper connection of the
equipment-grounding conductor can result in a risk of
electric shock. Check with a qualified electrician or service
representative if you are in doubt whether the appliance is
properly grounded.
AVERTISSEMENT :Le mauvais
branchement du fil de mise à la terre peut causer un choc
électrique. En cas de doute, consulter un électricien qualifié ou
un technicien pour déterminer si l’appareil est à la terre.
CAUTION:Automatically Operated Device –
To reduce the risk of injury disconnect from power supply
before servicing. This unit is equipped with an integral
disconnecting switch located inside the blower housing.
PRUDENCE :Appareil commandé
automatiquement. Afin de réduire les risques de blessure,
débranchez l’appareil de l’alimentation électrique avant
de procéder à une réparation. L’appareil est équipé d’un
sectionneur intégral situé à l’intérieur du logement du
ventilateur.
4
Installation Preparation
DUCT FITTINGS
This Hood Must Use an
d Round Duct. It Can
Transition to a
d[d Duct.
Use this chart to compute
maximum permissible lengths for
duct runs to outdoors.
NOTE: Do not exceed maximum
permissible equivalent lengths!
Maximum duct length:
IRRWIRUUDQJHKRRGV
Flexible ducting:
If flexible metal ducting is used,
all the equivalent feet values in
the table should be doubled.
The flexible metal duct should
be straight and smooth and
extended as much as possible.
DO NOT use flexible plastic
ducting.
NOTE: Any home ventilation
system, such as a ventilation
hood, may interrupt the proper
flow of combustion air and
exhaust required by fireplaces, gas
furnaces, gas water heaters and
other naturally vented systems.
To minimize the chance of
interruption of such naturally
vented systems, follow the
heating equipment manufacturer’s
guidelines and safety standards
such as those published by NFPA
and ASHRAE. When applicable,
install any makeup (replacement)
air system in accordance with local
building code requirements. Visit
GEAppliances.com for available
makeup air solutions.
Total
Equivalent Quantity Equivalent
Duct Piece Dimensions Length* Used Length
Round, 1 ft.
straight (per foot
length)
3-1/4" x 12" 1 ft.
straight (per foot
length)
90° elbow
17 ft.
45° elbow
10 ft.
ø[90° elbow 43 ft.
3-1/4" x 12"
45° elbow 26 ft.
3-1/4" x 12"
90° flat elbow 102 ft.
8" round to 3-1/4" x 12" transition 2 ft.
3-1/4" x 12" to 8"
round transition 5 ft.
8" round
to 3-1/4" x 12"
transition 90° elbow 6 ft.
3-1/4" x 12" to 8"
round transition 90° elbow 13 ft.
Round
wall cap
with damper 32 ft.
3-1/4” x 12" wall cap
with damper 75 ft.
Round
roof cap 44 ft.
* Actual length of straight duct plus duct fitting
equivalent. Equivalent length of duct pieces are
based on actual tests conducted by GE Evaluation
Engineering and reflect requirements for good
venting performance with any ventilation hood.
Total Duct Run
5
Installation Preparation
TOOLS AND MATERIALS REQUIRED
(NOT SUPPLIED)
Tape measure
Knife
Spirit level
Wire cutter/stripper
Wire nuts
Electric drill with 5/16" and 3/8" bits
Phillips and flat blade screwdrivers
Hammer
Pliers
Safety glasses
Duct tape
Tape to mount template
Gloves to protect against sharp edges
120V 60Hz. 15 or 20 Amp, 2 wire with
ground Properly grounded branch circuit
Strain relief for junction cover
8" round metal duct, length to suit
installation
Saw, jig saw or reciprocating saw
Measuring tape
Pliers
Duct tape
Strain relief
12” long
Phillips
head
screwdriver
Spirit level
Electric drill
with 5/16”
and 3/8” Bits
Safety glasses
Gloves
Knife
Wire cutter/
stripper
Hammer
Flat blade
screwdriver
Wire nuts
REMOVE THE PACKAGING
CAUTION: LIFT THE HOOD OUT OF THE BOX
BY THE CENTER METAL PORTION. DO NOT LIFT BY THE
GLASS SIDES.
PRUDENCE :LEVEZ LA HOTTE À
L’EXTÉRIEUR DE LA BOÎTE PAR LA PORTION MÉTAL
CENTRAL. NE LEVEZ PAS PAR LES CÔTÉS DE VERRE.
CAUTION:Wear gloves to protect against
sharp edges.
PRUDENCE :Portez des gants pour éviter
les blessures causées par les tranchants.
Masking tape
• Grasp the hood by the metal insert in the center
and lift straight up and out of the box.
• Remove and properly discard the plastic wrapping.
• Remove parts box, duct covers and other
packaging.
Saw, jig saw or
reciprocating
saw
8" round metal
duct, length to suit
installation
6
Installation Preparation
DETERMINE INSTALLATION HEIGHT
• Telescopic duct covers are provided to conceal
the ductwork running to the ceiling.
• This hood can be installed for recirculating
operation. No kits required.
NOTE: Measure
installation height
from the cooking
surface to the
outer glass portion
of the hood.
7'-11" 24" to 26" 24" to 26"
8'-0" 24" to 27" 24" to 27"
8'-1" 24" to 28" 24" to 28"
8'-2" 24" to 29" 24" to 29"
8'-3" 24" to 30" 24" to 30"
8'-4" 24" to 30" 24" to 30"
8'-5" 24" to 30" 24" to 30"
8'-6" 24" to 30" 24" to 30"
8'-7" 24" to 30" 24" to 30"
8'-8" 24" to 30" 24" to 30"
8'-9" 24" to 30" 24" to 30"
8'-10" 24" to 30" 25" to 30"
8'-11" 24" to 30" 26" to 30"
9'-0" 25" to 30" 24" to 30"
9'-1" 26" to 30" 24" to 30"
9'-2" 27" to 30" 24" to 30"
9'-3" 28" to 30" 24" to 30"
The vent hood must be installed 24" min. and
30" max. above the cooking surface. The hood
installation height, from the cooking surface to the
bottom of the hood, depends upon ceiling height.
ACCESSORIES:
• Order ZX90010 accessory for ZV900 wall mount
hood to reach ceiling heights between 9'-6" and
10'-5". This accessory contains one 40" long duct
cover.
9'-4" 29" to 30" 24" to 30"
9'-5" 30" 25" to 30"
9'-6" 24" to 30" 24" to 30"
9'-7" 24" to 30" 24" to 30"
9'-8" 24" to 30" 24" to 30"
9'-9" 24" to 30" 24" to 30
9"-10" 24" to 30" 24" to 30"
9'-11" 24" to 30" 24" to 30"
10' 24" to 30" 24" to 30"
10'-1" 24" to 30" 24" to 30"
10'-2" 25" to 30" 24" to 30"
10'-3" 26" to 30" 25" to 30"
10'-4" 27" to 30" 26" to 30"
10'-5" 28" to 30" 27" to 30"
*Based on 36d countertop height.
$&&(6625<=;
ACCESSORY ZX90010 SUPPLIED
7
Installation Preparation
CHECK INSTALLATION HARDWARE
Locate the hardware accessory box packed with the hood and check contents.
HARDWARE PACKAGE
Locate and count
screws
Air deflector for
recirculating
installation only
12-7/8”
12"
Duct bracket
3 wood
screws
2 thumb
screws
49-80405 04-06 JR
Drill 2 (two) 3/16≤pilot holes through studs or rear wall support
14-5/8≤
to top of
bracket
C
L
MOUNTING TEMPLA TE
3 wall
fasteners
12 hood
attachment
screws
REAR WALL
ALIGN BOTT OM EDGE
WITH PENCIL LINE,
INDICATING BOTT OM
OF THE HOOD
t
3 wall bracket
screws
1 charcoal filter for
recirculating installation
9-7/8"
27-3/4”
11-1/2”
11-1/2"
2-piece decorative duct
27-3/4"
23-7/8”
cover (dimension shown
for reference only)
Stainless steel filter
Mounting bracket
Wall mount template
8
Installation Instructions
,167$//$7,21³9(17('727+(2876,'(
DUCTWORK, WIRING LOCATIONS
Determine the exact location of the vent hood.
• Locate the template packed with the literature.
– Measure 36" from the floor to the top of the cooking
surface. Add hood installation height determined on
page 7. Mark that location.
– Use a level to draw a straight pencil line on the wall.
5-1/2” c enterline to wall
8-1/2” dia. hole
FOR WALL VENT DUCT
– Tape the template in position along the penciled
line. CHECK TO BE SURE THE TEMPLATE IS LEVEL.
FOR CEILING VENT DUCTING
Ceiling
Centerline 26” above
the marked bottom
pencil line for
installation height.
INSTALL FRAMING FOR HOOD
SUPPORT
IMPORTANT³ Framing must be capable of
supporting 100 lbs.
8-1/2” min. opening for ductwork
View from rear
cleats
1” x 6” min.
mounting
support
Centerline of
installation
space
Ceiling ducting:
If ductwork will vent straight up to the ceiling:
• Use a level to draw a line straight up, from the
centerline on the template to the ceiling.
• Measure 5-1/2" from the back wall to the centerline
of an 8-1/2" hole on the ceiling.
NOTE: If drywall is not present, add drywall thickness
to the 5-1/2" dimension.
Wall Ducting:
If ductwork will vent to the rear:
• Use a level to draw a line straight up from the
centerline on the template.
• Measure at least 26" above the pencil line that
indicates the bottom installation height, to the
centerline of an 8-1/2" dia. duct hole. (Hole may be
elongated for duct elbow.)
HOUSE WIRING LOCATION:
• The junction box is located on the top left side of the
hood.
• Wiring should enter the back wall at least 22" above
the bottom of the hood, and within 6" of the left side
of the centerline.
If drywall is present, mark the screw hole locations for
the top mounting brackets. Remove the template.
• Cut away enough drywall to expose 2 vertical studs
at the bracket location indicated on the template.
• Install a horizontal support at least 1" x 6" between
two wall studs at the bottom mounting bracket
installation location. The horizontal support must be flush with the room side of the studs. Use cleats
behind both sides of the support to secure to wall
studs.
• Reinstall drywall.
9
Installation Instructions
,167$//$7,21³9(17('727+(2876,'(
INSTALL MOUNTING BRACKET
This vent hood must be secured to the horizontal
support or wall studs.
• With the template taped in place, use a punch to
mark mounting bracket screw locations.
• Drill 3/16" pilot holes in 2 of the punched locations
in the lower bracket.
• Remove the template.
Drill 2 (two) 3/16≤pilot holes through studs or rear wall support
14-5/8≤
to top of
bracket
C
L
REAR WALL
MOUNTING TEMPLA TE
ALIGN BOTT OM EDGE
WITH PENCIL LINE,
INDICATING BOTT OM
49-80405 04-06 JR
OF THE HOOD
t
• Use wood screws to secure the mounting bracket
to the wall. The screws must engage wall studs or
the installed horizontal mounting support.
• Check to be sure that the bracket is level.
3
INSTALL DUCT BRACKET
The duct bracket should be installed against the
back wall and flush with the ceiling. This bracket will
hold the duct cover in place at the top.
Secure the bracket to the wall:
• Align the marked centerline on the bracket with
the centerline on the wall.
• Mark 2 screw hole locations in the wall.
• Drill 3/16" pilot holes in the marked locations.
• If pilot holes do not enter studs, enlarge the holes
to 3/8" and install wall fastener anchors.
• Drive screws, by hand, into the fasteners to allow
anchors to expand. Remove the screws.
• Secure the bracket to the wall with wood screws
and/or fasteners.
10
Installation Instructions
,167$//$7,21³9(17('727+(2876,'(
PREPARE THE HOOD
• Place the hood on a padded surface.
• Position the motor housing at the back of the hood.
Electrical connectors should face the front, with
rear mounting hooks at the back.
• Slip the bottom flange of the motor housing into
the side slots at the top rear opening.
Rear
mounting
hooks
• Carefully lay the hood on its back.
• Fasten the hood to the motor housing from the
bottom, using 6 screws.
Front side
Bottom view
Rear side
Rear view
Engage flange on
motor housing into slots
• Join two cable connectors at the front of the hood.
To Lights
To
Control
Panel
11
Installation Instructions
,167$//$7,21³9(17('727+(2876,'(
MOUNT THE HOOD
WARNING:2 people are required to lift and
position the hood onto the mounting bracket.
AVERTISSEMENT :
If faut deux personnes pour lever et mettre en place
la hotte sur le support de montage.
• Lift the hood onto the mounting bracket.
• Position a spirit level at the bottom of the hood to
check side to side leveling.
6
LEVEL THE HOOD
This hood has built-in levelers on the mounting hooks
at each side. Use a long Phillips screwdriver from the
front to access the levelers.
7
CONNECT DUCTWORK
• Install ductwork, making connections in the
direction of airflow as illustrated.
• Push duct over the exhaust outlet and damper.
• Secure joints in ductwork with sheetmetal screws.
• Wrap all duct joints and the flange connections
with duct tape for an airtight seal.
Airflow
Duct tape
over seam
and screw
Screw
CAUTION:Do not use sheet metal screws
at the hood flange connection. Doing so will prevent
proper damper operation. Seal connection with
tape only.
Levelers
• Use the top screw hole in the leveler to raise or lower
the hood on that side.
• Use the bottom screw hole to pull the hood tight
against the wall surface.
Screw hole
• Mark hole location at the bottom of the hood.
• Remove the hood. If the bottom screw hole does not
enter a stud, enlarge the hole to 3/8d and install wall
fastener anchors.
• Place the hood back onto the mounting bracket,
check level again and install the wall fastener.
PRUDENCE :
Il ne faut pas utiliser de vis autoraurdeuses à la
connexion du collet de la hotte. Ceci empêcherait
le bon fonctionnement du registre. N’utiliser que du
ruban adhésif pour assurer l’étanchéité du raccord.
12
Installation Instructions
,167$//$7,21³9(17('727+(2876,'(
CONNECT ELECTRICAL
Verify that power is turned off at the source.
WARNING:If house wiring is not 2-wire
with a ground wire, a ground must be provided by
the installer. When house wiring is aluminum, be sure
to use U.L. approved anti-oxidant compound and
aluminum-to-copper connectors.
AVERTISSEMENT :
Si la maison n’est pas câblee avec deux fils et un
fil de terre, l’installateur doit installer un fil de terre.
Quand les fils sont en aluminium, il faut prendre soin
d’utiliser des connecteurs aluminium à cuivre avec
une pâte antioxydante approuvée par U.L.
• Remove junction box cover and knockout on the
left side.
Knockout
J-Box
cover
• Secure the house wiring to the junction box with
a strain relief.
House wiring
J-Box
cover
• Connect white leads to branch circuit white lead.
• Connect black leads to branch circuit black lead.
• Connect green/yellow leads to branch circuit green
lead or bare ground lead.
• Secure all connections with wire nuts on each
electrical connector.
• Push wires into junction box and replace cover.
Be sure wires are not pinched.
• Secure J-Box cover with original screw.
13
Installation Instructions
,167$//$7,21³9(17('727+(2876,'(
INSTALL DUCT COVERS
• Place the decorative duct
covers on top of the hood.
NOTE: The inside (upper)
duct piece has holes on one
end. The holes are intended
for use when the hood is
installed for recirculating
purposes. Slide the inside end
into the outer piece; the vent
holes should not be visible in
this installation.
The inside duct piece must slip into the folded ends
of the outer section.
support bracket
Upper
duct cover
Mounting
screws
Duct cover
INSTALL FILTERS
IMPORTANT: Check to be sure that the main ON/
OFF switch next to the motor is in the ON position.
• Remove protective film on the filters.
Filter Lock
NOTE: The charcoal filter is not required for this
installation.
• Tip the filter into the left or right side of the
opening. Lift the filter to the opposite side and
into the filter lock.
• To remove the filter, pull the filter lock downward.
Duct cover
support bracket
Lower
duct cover
Lower duct
cover seat
• Extend the inner duct upward to the ceiling
bracket.
• Secure duct cover to ceiling bracket with 2 screws.
FINALIZE INSTALLATION
• Check to be sure all tape and packaging materials
have been removed.
• Refer to the Owner’s Manual for operating
instructions.
14
Installation Instructions
,167$//$7,21³5(&,5&8/$7,1*
DUCTWORK, WIRING LOCATIONS
• Determine the exact location of the vent hood.
• Locate the template packed with the literature.
• Measure 36
surface. Add hood installation height determined on
page 7. Mark that location.
• Tape the template in position along the penciled line.
CHECK TO BE SURE THE TEMPLATE IS LEVEL.
• Use a level to draw a line straight up, from the
centerline on the template to the ceiling.
d from the floor to the top of the cooking
Ceiling
1
INSTALL FRAMING FOR HOOD
SUPPORT
IMPORTANT: Framing must be capable of
VXSSRUWLQJOEV
View from rear
cleats
1” x 6” min.
mounting
support
Centerline of
installation
space
HOUSE WIRING LOCATION:
• The junction box is located on the top left side of
the hood.
• Wiring should enter the back wall at least 22
above the bottom of the hood, and within 6
of the centerline.
d
d
If drywall is present, mark the screw hole locations for
the top mounting brackets. Remove the template.
• Cut away enough drywall to expose 2 vertical studs
at the bracket location indicated on the template.
• Install a horizontal support at least 1" x 6"
between two wall studs at the bottom mounting
bracket installation location. The horizontal support must be flush with the room side of the studs.
Use cleats behind both sides of the support to
secure to wall studs.
• Reinstall drywall.
15
Installation Instructions
,167$//$7,21³5(&,5&8/$7,1*
INSTALL MOUNTING BRACKET
This vent hood must be secured to the horizontal
support or wall studs.
• With the template taped in place, use a punch to
mark mounting bracket screw locations.
• Drill 3/16" pilot holes in 2 of the punched locations
in the lower bracket.
• Remove the template.
Drill 2 (two) 3/16≤pilot holes through studs or rear wall support
14-5/8≤
to top of
bracket
C
L
REAR WALL
MOUNTING TEMPLA TE
ALIGN BOTT OM EDGE
WITH PENCIL LINE,
INDICATING BOTT OM
49-80405 04-06 JR
OF THE HOOD
t
• Use wood screws to secure the mounting bracket
to the wall. The screws must engage wall studs or
the installed horizontal mounting support.
• Check to be sure that the bracket is level.
3
INSTALL DUCT BRACKET
The duct bracket should be installed against the
back wall and flush with the ceiling. This bracket will
hold the duct cover in place at the top.
Secure the bracket to the wall:
• Align the marked centerline on the bracket with
the centerline on the wall.
• Mark 2 screw hole locations in the wall.
• Drill 3/16
d pilot holes in the marked locations.
• If pilot holes do not enter studs, enlarge the holes
d and install wall fastener anchors.
to 3/8
• Drive screws, by hand, into the fasteners to allow
anchors to expand. Remove the screws.
• Secure the bracket to the wall with wood screws
and/or fasteners.
16
Installation Instructions
,167$//$7,21³5(&,5&8/$7,1*
PREPARE THE HOOD
• Place the hood on a padded surface.
• Position the motor housing at the back of the hood.
Electrical connectors should face the front, with
rear mounting hooks at the back.
• Slip the bottom flange of the motor housing into
the side slots at the top rear opening.
Rear
mounting
hooks
Rear view
Engage flange on
motor housing into slots
• Carefully lay the hood on its back.
• Fasten the hood to the motor housing from the
bottom, using 6 screws.
Front side
MOUNT THE HOOD
WARNING:2 people are required to lift and
position the hood onto the mounting bracket.
AVERTISSEMENT :
If faut deux personnes pour lever et mettre en place
la hotte sur le support de montage.
• Lift the hood onto the mounting bracket.
• Position a spirit level at the bottom of the hood to
check side to side leveling.
6
LEVEL THE HOOD
This hood has built-in levelers on the mounting hooks
at each side. Use a long Phillips screwdriver from the
front to access the levelers.
Levelers
Bottom view
Rear side
• Join two cable connectors at the front of the hood.
To Lights
To
Control
Panel
• Use the top screw hole in the leveler to raise or lower
the hood on that side.
• Use the bottom screw hole to pull the hood tight
against the wall surface.
Screw hole
• Mark hole location at the bottom of the hood.
• Remove the hood. If the bottom screw hole does not
enter a stud, enlarge the hole to 3/8d and install wall
fastener anchors.
• Place the hood back onto the mounting bracket,
check level again and install the wall fastener.
17
Installation Instructions
,167$//$7,21³5(&,5&8/$7,1*
7
SIZE AND CUT DUCT PIECE
• Hold upper air deflector
with duct connector
against the ceiling.
• Measure from the bottom
of the air deflector to the
top of the hood as
shown. Reduce
that dimension by
1" to facilitate installation.
The duct will cover
and overlap the deflector
and the hood outlets.
Deflector
Measure
length
• Cut the duct piece to size and
slip onto the bottom of the
deflector.
• Place the assembled deflector
and duct over the exhaust
outlet.
• Hold the assembly against the
duct bracket.
• Drive 4 screws into the bottom
of the deflector and into the
bracket.
• Use duct tape to seal duct
to the deflector and at the
exhaust outlet.
Duct
length
CONNECT ELECTRICAL
Verify that power is turned off at the source.
WARNING: If house wiring is not 2-wire
with a ground wire, a ground must be provided by
the installer. When house wiring is aluminum, be
sure to use U.L. approved anti-oxidant compound
and aluminum-to-copper connectors.
AVERTISSEMENT :
Si la maison n’est pas câblee avec deux fils et un
fil de terre, l’installateur doit installer un fil de terre.
Quand les fils sont en aluminium, il faut prendre soin
d’utiliser des connecteurs aluminium à cuivre avec
une pâte antioxydante approuvée par U.L.
• Remove junction box cover and knockout on the
left side.
Knockout
J-Box
cover
• Secure the house wiring to the junction box with
a strain relief.
House wiring
J-Box
cover
• Connect white leads to branch circuit white lead.
• Connect black leads to branch circuit black lead.
• Connect green/yellow leads to branch circuit
green lead or bare ground lead.
• Secure all connections with wire nuts on each
electrical connector.
• Push wires into junction box and replace cover.
Be sure wires are not pinched.
• Secure J-Box cover with original screw.
18
Installation Instructions
,167$//$7,21³5(&,5&8/$7,1*
INSTALL DUCT COVERS
• Place the decorative duct
covers on top of the hood.
NOTE: The inside piece has
holes on one end intended for
use when the hood is installed
for recirculating purposes.
Be sure the vented end is at
the top; the vent holes will
be visible in this installation.
The inside duct piece must slip
into the folded ends on the outer
section.
Duct cover
support bracket
Upper
duct cover
Mounting
screw holes
Vent holes
INSTALL FILTERS
IMPORTANT: Check to be sure that the main ON/
OFF switch next to the motor is in the ON position.
Charcoal filter
• Install the black charcoal filter into the center
opening. Secure the filter with thumbscrews on
each side.
Metal filter
Filter Lock
Duct cover
support bracket
Lower
duct cover
Lower duct
cover seat
• Extend the inner duct upward to the ceiling
bracket.
• Secure duct cover to ceiling bracket with 2 screws.
• Tip the filter into the left or right side of the
opening. Lift the filter to the opposite side and into
the filter lock.
• To remove the filter, pull the filter lock downward.
FINALIZE INSTALLATION
• Remove all tape and packing material.
• Refer to the Owner’s Manual for operating
instructions.
19
NOTE: While performing installations described in this book,
safety glasses or goggles should be worn.
For Monogram® local service in your area, call
1.800.444.1845.
NOTE: Product improvement is a continuing endeavor at
General Electric. Therefore, materials, appearance and
specifications are subject to change without notice.
49-80328-3
02-13 GE
Printed in Mexico
GE Appliances & Lighting
Appliances
General Electric Company
Louisville, KY 40225
monogram.com
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.